• Title/Summary/Keyword: Energy total operation

Search Result 437, Processing Time 0.024 seconds

Effects of Multiple-CycleOperation and $SO_2$ Concentration on the Absorption Characteristics of $CO_2$ by means of Limestone (석회석의 $CO_2$의 흡수특성에 미치는 흡수/재생 반응의 반복횟수와 $SO_2$ 농도의 영향)

  • Ryu Ho-Jung
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.203-211
    • /
    • 2005
  • To investigate the effects of the number of multiple-cycles and $SO_2$ concentration on $CO_2$ absorption characteristics by means of limestone, $CO_2$ capture capacity has been measured in a bubbling fluidized bed reactor (0.1m 1.D., 1.17m high). Danyang limestone was used as a $CO_2$ sorbent and the number of cycles $(\~10th\;cycle)$ and $SO_2$ concentrations (0, 2000, 4000 ppm) were considered as variables. The measured $CO_2$ capture capacity decreased as the number of cycles increased and it showed $50\%$ or initial value after 10 cycles. Moreover, $CO_2$ rapture capacity decreased with 501 concentrations. For three different $SO_2$ concentrations, the total CaO utilization was almost the same but $SO_2$ capture capacity increased and $CO_2$ capture capacity decreased as $SO_2$ concentration increased. These results suggest that $SO_2$ capture reaction is predominant over $CO_2$ capture reaction in the simultaneous $CO_2/SO_2$ capture conditions.

Current Status of the Radioactive Waste Management Program in Korea

  • Park, H-S;Hwang, Y-S;Kang, C-H
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.140-142
    • /
    • 2004
  • Since the April of 1978, Korea has strongly relied on the nuclear energy for electricity generation. As of today, eighteen nuclear power plants are in operation and ten are to be inaugurated by 2015. The installed nuclear capacity is 15, 716 MW as of the end of 2002, representing 29.3% of the nation's total installed capacity. The nuclear share in electricity remains around 38.9 at the end of 2002, reaching at the level of 119 billion kWh's. New power reactors, KSNP's (Korea Standard Nuclear Power Plant) are fully based on the domestic technologies. More advanced reactors such as KNGR (Korea Next Generation Reactor) will be commercialized soon. Even though the front end nuclear cycle enjoys one of the best positions in the world, there have been some chronical problems in the back end fuel cycle. That's the one of the reason why we need more active R&D programs in Korea and active international and regional cooperation in this area. The everlasting NIMBY problem hinders the implementation of the nation's radioactive waste management program. We expect that the storage capacity for the LILW(Low and Intermediate Level radioactive Waste) will be dried out soon. The situation for the spent fuel storage is also not so favorable too. The storage pools for spent fuel are being filled rapidly so that in 2008, some AR pools cannot accommodate any more new spent nuclear fuels. The Korean Government in strong association with utilities and national academic and R&D institutes have tried its best effort to secure the site for a LILW repository and a AFR site. Finally, one local community, Buan in Jeonbook Province, submitted the petition for the site. At the end of the last July, the Government announced that the Wido, a small island in Buan, is suitable for the national complex site. The special force team headed by Dr IS Chang, president of KAERI teamed with Government officials and many prominent scholars and journalists agreed that by the evidences from the preliminary site investigation, they could not find any reason for rejecting the local community's offer.

  • PDF

Preparation of Styrene-Ethyl acylate Core-shell Structured Detection Materials for aMeasurement of the Wall Contamination by Emulsion Polymerization

  • Hwang, Ho-Sang;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.84-85
    • /
    • 2009
  • New approaches for detecting, preventing and remedying environmental damage are important for protection of the environment. Procedures must be developed and implemented to reduce the amount of waste produced in chemical processes, to detect the presence and/or concentration of contaminants and decontaminate fouled environments. Contamination can be classified into three general types: airborne, surface and structural. The most dangerous type is airborne contamination, because of the opportunity for inhalation and ingestion. The second most dangerous type is surface contamination. Surface contamination can be transferred to workers by casual contact and if disturbed can easily be made airborne. The decontamination of the surface in the nuclear facilities has been widely studied with particular emphasis on small and large surfaces. The amount of wastes being produced during decommissioning of nuclear facilities is much higher than the total wastes cumulated during operation. And, the process of decommissioning has a strong possibility of personal's exposure and emission to environment of the radioactive contaminants, requiring through monitoring and estimation of radiation and radioactivity. So, it is important to monitor the radioactive contamination level of the nuclear facilities for the determination of the decontamination method, the establishment of the decommissioning planning, and the worker's safety. But it is very difficult to measure the surface contamination of the floor and wall in the highly contaminated facilities. In this study, the poly(styrene-ethyl acrylate) [poly(St-EA)] core-shell composite polymer for measurement of the radioactive contamination was synthesized by the method of emulsion polymerization. The morphology of the poly(St-EA) composite emulsion particle was core-shell structure, with polystyrene (PS)as the core and poly(ethyl acrylate) (PEA) as the shell. Core-shell polymers of styrene (St)/ethyl acrylate (EA) pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl sulfate (SOS) as an emulsifier using ammonium persulfate (APS) as an initiator. The polymer was made by impregnating organic scintillators, 2,5-diphenyloxazole (PPO) and 1,4-bis[5-phenyl-2-oxazol]benzene (POPOP). Related tests and analysis confirmed the success in synthesis of composite polymer. The products are characterized by IT-IR spectroscopy, TGA that were used, respectively, to show the structure, the thermal stability of the prepared polymer. Two-phase particles with a core-shell structure were obtained in experiments where the estimated glass transition temperature and the morphologies of emulsion particles. Radiation pollution level the detection about under using examined the beta rays. The morphology of the poly(St-EA) composite polymer synthesized by the method of emulsion polymerization was a core-shell structure, as shown in Fig. 1. Core-shell materials consist of a core structural domain covered by a shell domain. Clearly, the entire surface of PS core was covered by PEA. The inner region was a PS core and the outer region was a PEA shell. The particle size distribution showed similar in the range 350-360 nm.

  • PDF

The Effect of the Reaction Time Increases of Microbubbles with Catalyst on the Nitrogen Reduction of Livestock Wastewater (가축분뇨의 마이크로버블과 촉매와의 반응 시간 증가에 따라 질소 제거에 미치는 영향)

  • Jang, Jae Kyung;Sung, Je Hoon;Kang, Youn Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.578-582
    • /
    • 2015
  • It was investigated whether the removal of nitrogen ions included livestock wastewater were increased by increasing the reaction time of livestock wastewater and microbubbles with catalyst. For this study, the nitrogen reduction system using microbubbles with catalyst was used. The two reactors were consecutively arranged, and the second reactor (Step 2) was located to next the first reactor (Step 1). Each reactor was reacted for 2 hours and air or oxygen as oxidant was fed into the reactor during operation before microbubble device. When oxygen was used, ammonia nitrogen was removed each 18.3% and 52.8% during 2 (only step 1) and 4 (step 1 and step 2) hours reactions. This value was higher than that of when air was fed. When oxygen was used, the longer the reaction time, the ammonia nitrogen removal was higher. The longer the reaction time, the higher the nitrite and nitrate was also removed such as ammonia nitrogen. Also this system was examined whether organic matter removal is effective. The total chemical oxygen demand (TCOD) removal was higher than the soluble chemical oxygen demand (SCOD). Some materials among causing substances COD were difficult to decompose biologically. Therefore, it means that it will be easy to operate the biological processes following step and reduce the concentration of organic contaminants in effluent.

A Threshold Controller for FAST Hardware Accelerator (FAST 하드웨어 가속기를 위한 임계값 제어기)

  • Kim, Taek-Kyu;Suh, Yong-Suk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.187-192
    • /
    • 2014
  • Various researches are performed to extract significant features from continuous images. The FAST algorithm has the simple structure for arithmetic operation and it is easy to extraction the features in real time. For this reason, the FPGA based hardware accelerator is implemented and widely applied for the FAST algorithm. The hardware accelerator needs the threshold to extract the features from images. The threshold is influenced not only the number of extracted features but also the total execution time. Therefore, the way of threshold control is important to stabilize the total execution time and to extract features as much as possible. In order to control the threshold, this paper proposes the PI controller. The function and performance for the proposed PI controller are verified by using test images and the PI control logic is designed based on Xilinx Vertex IV FPGA. The proposed scheme can be implemented by adding 47 Flip Flops, 146 LUTs, and 91 Slices to the FAST hardware accelerator. This proposed approach only occupies 2.1% of Flip Flop, 4.4% of LUTs, and 4.5% of Slices and can be regarded as a small portion of hardware cost.

Study on Determination of Design Factor of Bioreactor for Sulfate Reduction in Mine Drainage (광산배수 내 황산염 저감을 위한 생물반응기의 설계인자 도출 연구)

  • Kim, Kang-Ho;Kang, Chan-Ung;Kim, Sun-Joon;Kim, Tae-Heok;Ji, Won-Hyun;Jang, Hang-Seok;Park, Hyun-Sung
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.527-537
    • /
    • 2018
  • Column tests of a sulfate reducing bacteria (SRB) bioreactor were conducted to determine the design factors for sulfate-rich mine drainage. Various substrates were applied to the bioreactor, including cow manure and its mixture with a mushroom compost, with rice straw and limestone as subsidiary materials. This procedure provided a removal efficiency of up to 82% of the total sulfur with the mixture of cow manure (70%), mushroom compost (10%) and rice straw (20%), and higher efficiencies were observed after 2 days of retention time. In the downflow condition of the flow direction, oxygen supply and re-oxidation of the sulfates occurred, causing a decrease in sulfate removal efficiency. The addition of an inorganic sludge containing heavy metals, which was intended for production of metal-sulfides in the bioreactor, had a negative effect on the long-term operation owing to arsenic release and toxicity to the SRB. The results thus show that a bioreactor using a mixed substrate with cow manure and operating in the downflow direction could reduce sulfates and total dissolved sulfur content; this process confirms the applicability of the SRB bioreactor to sulfate-rich saline drainage.

Parametric Study on Effect of Floating Breakwater for Offshore Photovoltaic System in Waves (해상태양광 구조물용 부유식 방파제의 파랑저감성능 평가)

  • Kim, Hyun-Sung;Kim, Byoung Wan;Lee, Kangsu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2022
  • There has been an increasing number of studies on photovoltaic energy generation system in an offshore site with the largest energy generation efficiency, as increasing the researches and developments of renewable energies for use of offshore space and resources to replace existing fossil fuels and resolve environmental challenges. For installation and operation of floating photovoltaic systems in an offshore site with harsher environmental conditions, a stiffness of structural members comprising the total system must be reinforced to inland water spaces as dams, reservoirs etc., which have relatively weak condition. However, there are various limitations for the reinforcement of structural stiffness of the system, including producible size, total mass of the system, economic efficiency, etc. Thus, in this study, a floating breakwater is considered for reducing wave loads on the system and minimizing the reinforcement of the structural members. Wave reduction performances of floating breakwaters are evaluated, considering size and distance to the system. The wave loads on the system are evaluated using the higher-order boundary element method (HOBEM), considering the multi-body effect of buoys. Stresses on structural members are assessed by coupled analyses using the finite element method (FEM), considering the wave loads and hydrodynamic characteristics. As the maximum stresses on each of the cases are reviewed and compared, the effect of floating breakwater for floating photovoltaic system is checked, and it is confirmed that the size of breakwater has a significant effect on structural responses of the system.

A Study on Time Series Analysis of Membrane Fouling by using Genetic Algorithm in the Field Plant (유전자알고리즘을 이용한 막오염 시계열 예측 연구)

  • Lee, Jin Sook;Kim, Jun Hyun;Jun, Yong Seong;Kwak, Young Ju;Lee, Jin Hyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.444-451
    • /
    • 2016
  • Most research on membrane fouling models in the past are based on theoretical equations in lab-scale experiments. But these studies are barely suitable for applying on the full-scale spot where there is a sequential process such as filtration, backwash and drain. This study was conducted in submerged membrane system which being on operation auto sequentially and treating wastewater from G-water purification plant in Incheon. TMP had been designated as a fouling indicator in constant flux conditions. Total volume of inflow and SS concentration are independent variables as major operation parameters and time-series analysis and prediction of TMP were conducted. And similarity between simulated values and measured values was assessed. Final prediction model by using genetic algorithm was fully adaptable because simulated values expressed pulse-shape periodicity and increasing trend according to time at the same time. As results of twice validation, correlation coefficients between simulated and measured data were $r^2=0.721$, $r^2=0.928$, respectively. Although this study was conducted limited to data for summer season, the more amount of data, better reliability for prediction model can be obtained. If simulator for short range forecast can be developed and applied, TMP prediction technique will be a great help to energy efficient operation.

Spent-GAC Regeneration Using Variable Frequency Sono-Fenton Oxidation (가변 주파수 Sono-Fenton 산화를 이용한 Spent-GAC 재생기술)

  • Joo, Soobin;Lee, Sangmin;Kim, Hyungjun;Shim, Intae;Kim, Heejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.449-458
    • /
    • 2023
  • As an adsorption technology for dissolved organic matter, the adsorption capacity of granular activated carbon, GAC, can be applied, but activated carbon whose adsorption capacity is significantly reduced by use is inevitably replaced or regenerated. However, due to the economics of replacement cost, thermal regeneration method is used commercially, but high energy cost and loss of activated carbon occur under high temperature conditions above 800℃. In this study, the Sono-Fenton method, a multi-oxidation technology that combines Fenton oxidation and ultrasonic oxidation, was applied to improve the regeneration efficiency of spent GAC used to treat dissolved organic matter in combined sewer overflows (CSOs), and the regeneration efficiency of spent GAC by oxidant and ultrasonic frequency was investigated. In the applied Sono-Fenton treatment, the highest regeneration efficiency of 68.5% was obtained under the regeneration conditions of Fe2+ 10 mmol/L, H2O2 concentration 1,000 mmol/L, ultrasonic treatment time of 120 min, and ultrasonic frequency of 40 kHz. And similar efficiency was also obtained at 750 kHz, while ultrasonic waves of other frequencies had poor regeneration efficiency, and the magnitude of frequency and GAC regeneration efficiency did not show a linear relationship. In the case of continuous operation of the GAC adsorption tower with CSOs prepared by diluting raw sewage, about 700 hours of operation without regeneration was possible, and as a result of applying one Sono-Fenton treatment, 40-70% CODcr removal efficiency was obtained during a total of 1,000 hours of GAC adsorption operation.

Analysis of Temperature and Humidity Distributions according to Arrangements of Air Circulation Fans in Single-span Tomato Greenhouse (토마토 단동온실에서 공기순환팬 설치 방법에 의한 온실 내 온습도 분포 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Paek, Yee;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.277-282
    • /
    • 2016
  • This study was aimed to investigate the effect of air-circulation fans on air temperature and relative humidity in a single-span tomato greenhouse (W: 7m, L: 25m, H: 3.2m). According to standard of fan layout by ASAE (1997), a total of 10 fans were bilaterally arranged in 2 rows in the experimental greenhouse. The distributions of air temperature and relative humidity were measured from 6 pm to 8 am under different conditions, with and without fans. The measurement heights were 0.7m, 1.7m and 2.7m. Under the condition of "fans off", the spatial differences of air temperature and relative humidity between upper and lower sides were $1.7^{\circ}C$ and 10.8%, respectively. The operation of 10 fans showed their differences to $0.1^{\circ}C$ and 3.2%. The number of fans and installation direction were evaluated their performance on reducing the spatial variation of air temperature and relative humidity. The experimental layouts were 5 and fans in 2 rows (bilaterally) and 10 fans in the one (same) direction. Under the condition of "6 fans on" and "5 fans on", the spatial differences of air temperature and relative humidity between upper and lower side were $0.3^{\circ}C$, 3.4% and $0.3^{\circ}C$ and 4.0%. The operation of 10 fans in the one direction reduced their differences to $0.5^{\circ}C$ and 4.9%. The overall findings of this study showed that there was no significant differences under each condition. Therefore, this study suggested that it is more economic and effective to install five fans in 2 rows (bilaterally) in the greenhouse (W: 7m, L: 25m, H: 3.2m).