• Title/Summary/Keyword: Energy total operation

Search Result 437, Processing Time 0.024 seconds

An Economic Evaluation of MSW RDF Production Plant (생활폐기물 고형연료(RDF) 제조기술 경제성 평가)

  • Choi, Yeon-Seok;Choi, Hang-Seok;Kim, Seock-Joon
    • New & Renewable Energy
    • /
    • v.7 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • The waste treatment fee and energy production effect of Wonju city RDF plant, the first RDF manufacturing plant in Korea, were investigated in the study. All plant operation data, like total weight of received wastes, produced RDF and separated rejects in processes were fully recorded for mass balance calculation of the plant in 2009. Also all consumed oil and electricity were recorded for energy balance calculation. The results showed that the waste treatment fee not including the RDF sales price of 25,000 won/ton-RDF was 116,573 won/ton-MSW and it went down to 105,298 won when included the RDF price. Produced RDF was 40.2% of total received waste in weight. Three components analysis by mass balance calculation of total received waste showed that Wonju city's MSW was 32.4% of combustible, 37.5% of water and 30.1% of incombustible respectively. Energy effect was found that total amount of produced energy was about 4 times more than that of consumed energy.

Optimal Operation Model of Battery Energy Storage System(BESS) for High Voltage Customer (고압수용가용 전지전력저장시스템의 최적 운전모형 수립에 관한 연구)

  • Kim, Eung-Sang;Kim, Jae-Eon;Kim, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1192-1194
    • /
    • 1998
  • This paper presents a optimal operation algorithm of 1MW class Battery Energy Storage System (BESS) which is constructed in EHWA electric corporation. Total electric charge of conventional '97 year and simulated '98 year are compared to verify the validity of the proposed algorithm. Simulation results have showed that the about \\32,000,000 reduction of electric charge for 1 year.

  • PDF

A Study on Transient Operation Characteristics of 30kW Scale CVCF Inverter based Micro-grid (30kW급 CVCF 인버터 기반 Micro-grid의 구현 및 과도상태 운용특성에 관한 연구)

  • Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Park, Ji-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.18-25
    • /
    • 2019
  • Recently, micro-grids based on a CVCF inverter have been replacing diesel generators to reduce CO2 emissions in island areas with the increase of renewable energy sources. Stable operation methods are also being researched. These micro-grids may cause energy sinking if the total output of renewable energy sources is larger than the total customer loads. In the case of energy sinking, the voltage of a CVCF battery could rapidly increase according to the condition of SOC, and blackout could occur in the micro-grid due to the operation of a protection device in a CVCF inverter. Therefore, this paper analyzes the operation characteristics of a CVCF-inverter-based micro-grid when energy sinking occurs and proposes a transient operation strategy to prevent shut-down of the CVCF inverter. A test device of a 30-kW CVCF-inverter-based micro-grid was implemented, and the transient operation characteristics for the energy sinking phenomenon are presented. The simulation results confirm that blackout can be properly prevented according to the conditions of SOC and voltage in a CVCF battery.

Feasibility of Long Term Feed and Bleed Operation For Total Loss of Feedwater Event

  • Kwon, Young-Min;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.257-264
    • /
    • 1996
  • The conventional Equipment Environment Qualification (EEQ) envelope is developed based on the containment responses during the design basis events. The Safety Depressurization System (SDS) design without In-containment Refueling Water Storage Tank (IRWST) adopted in the Ulchin 3&4 challenges the conventional EEQ envelope during long term Feed and Bleed (F&B) operation due to the direct discharge of high mass and energy into the containment. Therefore, it is necessary to confirm that the containment pressure and temperature history during the long term F&B operation does not violate the conventional EEQ envelope. However, this subject has never been quantitatively assessed before. To investigate the success path of long term F&B operation this paper analyzes the thermal hydraulic response of the containment and Reactor Coolant System (RCS) until the completion of depressurization and cooldown of RCS into Shutdown Cooling System (SCS) entry condition. It is found that the SCS entry condition can be reached within 6 hours without violating the EEQ curve by proper operation of SDS valves, High Pressure Safety Injection (HPSI) pumps and active Containment Heat Removal System (CHRS). The suggested strategy not only demonstrates the feasibility of long term F&B operation but also can be utilized in the preparation of Emergency Procedure Guidelines (EPGs)

  • PDF

Operation Algorithm of Battery Energy Storage System (BESS) for Saving Electric Charges (전기요금 절감 측면에서 에너지저장시스템의 운전알고리즘)

  • 김응상
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.519-524
    • /
    • 1999
  • this paper proposes the operation algorithm of 1MW class Battery Energy Storage System(BESS) installed at the extra-high voltage customer. The objective of the proposed algorithm is to reduce electric charges during the operation of the BESS interconnected to power system. This paper simulates the electric charges in 1998 considering Season and Time of Use Rate and Power Factor in the assumption that electricity demand in 1998 is the same amount of that in 1997 and shows the saving of about 40 million won in the total electric charges. The results comparing the real electric charges of June. July and August in 1997 with that in 1998 show that the implementation of the proposed algorithm could significantly reduce electric charges during the operation the BESS.

  • PDF

Highly Intergrated Total Energy System and its Application in a Competitive Electricity Market (전력수급 종합시스템의 현황분석 및 전력산업 구조개편에 따른 전망)

  • Kim, Jung-Hoon;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1501-1505
    • /
    • 1999
  • Highly Integrated Total Energy System for system operational planning and analysis is a totally integrated computerized system for various parts of power system operation planning and power system analysis. It is developed by KEPCO for about 8 years, named HITES. Nowadays restructuring, deregulation, privatization and competition of electricity market is introduced in the world. This paper describes HITES application for two typical models of a competitive electricity market.

  • PDF

Secure and Energy-Efficient Join-Leave Operations in ZigBee Network

  • Kim, Bong-Whan;Park, Chang-Seop
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.11
    • /
    • pp.2874-2892
    • /
    • 2013
  • Since security plays an important role in several ZigBee applications, such as Smart Energy and medical sensor applications, ZigBee Specification includes various security mechanisms to protect ZigBee frames and infrastructure. Among them, the Join and Leave operations of ZigBee are investigated in this paper. The current Join-Leave operation is protected by the network key (a kind of group key). We claim it is not adequate to employ the network key for such purpose, and propose a new Join-Leave operation protected by the application link key (a kind of pairwise key), which is based on a more efficient key management scheme than that of ZigBee. Hence, the original Join operation consists of a total of 12 command frames, while the new Join operation consists of only 6 command frames. In particular, the security of the proposed Join-Leave operation is equivalent to or better than that of the original Join-Leave operation. The new Join-Leave operation is extensively analyzed in terms of security and efficiency, and compared with the original Join-Leave operation of ZigBee.

An On-line System Architecture for Remote Energy Monitoring of CNC Machine Tools (CNC 기계의 원격 에너지 모니터링을 위한 온라인 시스템 구조)

  • Nam, Sung-Ho;Song, Ki-Hyeong;Baek, Jae-Yong;Lee, Dong-Yoon;Ryu, Kwang-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.480-485
    • /
    • 2013
  • Enhancing energy efficiency of machine tools causes substantial impacts on the manufacturing industries, to cope with the competitive introduction of the total energy management strategies. Real-time energy monitoring is essential to identify energy consumption patterns of the machine tools and correlate them with the energy management strategy. Integrated analysis of machine tool's operation status and the corresponding energy usage is most important to accurately evaluate the energy efficiency under the various machining process environments. This paper proposes a system architecture to realize the online energy monitoring system and the embedded energy monitoring approach interconnected with the CNC kernel. The shop-floor operation management system is presented to integrate the proposed online energy monitoring approach.

Simulation on Energy Consumption in the Summer Season Operation of primary HVAC system for Multipurpose Building Complex (다목적 복합건물의 하절기 열원기기 운전시 소비전력에 관한 시뮬레이션)

  • Suh, Jae-Kyoung;Choi, Seung-Gil;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.903-908
    • /
    • 2006
  • Building energy simulation has become a useful tool for predicting cooling, heating and air-conditioning loads for facilities. It is important to provide building energy performances feed back to the mechanical and electrical system operator and engineer for energy conservation and maintenance of building. From this research, we set up the typical weather data of location, basic description of building, geometric modelling data and the specification of Installed primary HVAC system for establishing the simulation model about energy consuming that take place in multipurpose building complex. The simulation tool of building energy - EnergyPlus (DOE and BLAST based simulation S/W), it has been used and accomplished calculations and analyses for evaluating the effect of the system types and operating condition of central HVAC plant on the building energy consumption. In this paper, we offer comparison and simultaneous results those involve electricity consumption pattern and amount between actual operation versus EnergyPlus simulation to the object building during summer season.

  • PDF

Innovative technologies for spent fuel safe management at Ignalina channel-type reactors

  • Babilas, Egidijus;Dokucajev, Pavel;Janulevicius, Darius;Markelov, Aleksej;Pabarcius, Raimondas;Rimkevicius, Sigitas;Uspuras, Eugenijus;Vaisnoras, Mindaugas
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.504-511
    • /
    • 2018
  • In Lithuania, all spent nuclear fuel (SNF) resulted from the operation of the Ignalina Nuclear Power Plant (INPP), which had two Russian Acronym for "Channelized Large Power Reactor"-type reactors. After the final shutdown, the total amount of SNF at the INPP was approximately 22,000 fuel assemblies. All these assemblies will be stored for about 50 years and disposed of after that. The decision to shut down and decommission both reactors in Lithuania before termination of design period raises a significant challenge for the treatment of accumulated SNF. Therefore, various techniques and technologies for SNF management were developed and justified for that specific case, and a set of special equipment was installed at the INPP, the effectiveness of which was demonstrated during its operation. This article presents unique techniques related to the management of SNF adopted and commissioned at the INPP after its operation shutdown, namely fuel rod cladding leak tightness control system and special equipment for collection of possible spillage during handling of SNF assembly in the hot cell. The operational experience and measurement results of fuel rod cladding leak tightness control system are presented.