• Title/Summary/Keyword: Energy system analysis

Search Result 6,740, Processing Time 0.043 seconds

Analysis of Building Energy using Automated Weather System Data (자동 기상관측 자료를 이용한 건축물 에너지 분석)

  • Lee, Kwi-Ok;Kang, Dong-Bae;Lee, Kang-Yoel;Jung, Woo-Sik;Sim, Je-Hean;Yoon, Seong-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.493-502
    • /
    • 2014
  • EnergyPlus is a whole building energy simulation program that engineers, architects, and researchers use to model energy and water use in buildings. Modeling the performance of a building with EnergyPlus enables building professionals to optimize the building design to use less energy and water. This program provides energy analysis of building and needs weather data for simulation. Weather data is available for over 2,000 locations in a file format that can be read by EnergyPlus. However, only five locations are avaliable in Korea. This study intends to use AWS data for having high spatial resolution to simulate building energy. The result of this study shows the possibility of using AWS data for energy simulation of building.

An Economic Evaluation under Thailand Feed in Tariff of Residential Roof Top Photovoltaic Grid Connected System with Energy Storage for Voltage Stability Improving

  • Treephak, Kasem;Saelao, Jerawan;Patcharaprakiti, Nopporn
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.120-128
    • /
    • 2015
  • In this paper, Residential roof top photovoltaic system with 9.9 kW design is proposed. The system composed of 200 Watts solar array 33 panels connecting in series 10 strings and parallels 3 strings which have maximum voltage and current are 350 V and 23.8 A. The 10 kW sinusoidal grid-connected inverter with window voltage about 270-350 is selected to convert and transfer DC Power to AC Power at PCC (Point of Common Coupling) of power system following to utility standard. However the impact of fluctuation and uncertainty of weather condition of PV may decrease the voltage stability and voltage collapse of power system. In order to solve this problem the energy storage such 120 V 1200 Ah battery bank and 30 kVAR capacitor are designed for voltage stability control. The other expensed for installing the system such battery charger, cable, accessories and maintenance cost are concerned. The economic analysis by using investment from money loan with interest about 7% and use own money which loss income of deposit about 3% are calculated as 671,844 and 547,044 for PV system with energy storage and non energy storage respectively. The solar energy from PV is about 101,616 Bath per year which evaluated by using the value of $5kWh/m^2/day$ from average peak sun hour (PSH) of the Thailand and 6.96 Bath/kWh of Feed in Tariff Incentive. The payback periods of four scenarios are proposed follow as i) PV system with energy storage and use loan money is 15 years ii) PV system with no energy storage and use loan money is 10 years iii) PV system with energy storage and use deposit money is 9 years iv) PV system with energy storage and use deposit money is 7 years. In addition, the other scenarios of economic analysis such no FIT support and other type of economic analysis such NPV and IRR are proposed in this paper.

Improvement of aseismic performance of a PGSFR PHTS pump

  • Lee, Seong Hyeon;Lee, Jae Han;Kim, Sung Kyun;Kim, Jong Bum;Kim, Tae Wan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1847-1861
    • /
    • 2020
  • A design study was performed to improve the limit aseismic performance (LSP) of a primary heat transport system (PHTS) pump. This pump is part of the primary equipment of a prototype generation IV sodium-cooled fast reactor (PGSFR). The LSP is the maximum allowable seismic load that still ensures structural integrity. To calculate the LSP of the PHTS pump, a structural analysis model of the pump was developed and its dynamic characteristics were obtained by modal analysis. The floor response spectrum (FRS) initiated from a safety shutdown earthquake (SSE), 0.3 g, was applied to the support points of the PHTS pump, and then the seismic induced stresses were calculated. The structural integrity was evaluated according to the ASME code, and the LSP of the PHTS pump was calculated from the evaluation results. Based on the results of the modal analysis and LSP of the PHTS pump, design parameters affecting the LSP were selected. Then, ways to improve the LSP were proposed from sensitivity analysis of the selected design variables.

The Development of Equivalent System Technique for Deriving an Energy Function Reflecting Transfer Conductances (선로저항을 반영하는 에너지함수 유도를 위한 등가시스템 기법의 개발)

  • Moon, Young-Hyun;Cho, Byoung-Hoon;Roh, Tae-Hoon;Choi, Byoung-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1175-1182
    • /
    • 1999
  • This paper shows that a well-defined energy function can be developed to reflect the transfer conductances for multi-machine power systems under an assumption that all transmission lines have uniform R/X rations. The energy function is derived by introducing a pure reactive equivalent system for the given system. In this study, a static energy function reflecting transfer conductances is also derived as well as the transient energy function. The proposed static energy function is applied to voltage stability analysis and tested for various sample systems. The test results show that the accuracy of voltage stability analysis can be considerable improved by reflecting transfer conductances into the energy function.

  • PDF

Development of a System Analysis Code, SSC-K, for Inherent Safety Evaluation of The Korea Advanced Liquid Metal Reactor

  • Kwon, Young-Min;Lee, Yong-Bum;Chang, Won-Pyo;Dohee Hahn;Kim, Kyung-Doo
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.209-224
    • /
    • 2001
  • The SSC-K system analysis code is under development at the Korea Atomic Energy Research Institute (KAERI) as a part of the KALIMER project. The SSC-K code is being used as the principal tool for analyzing a variety of off-normal conditions or accidents of the preliminary KALIMER design. The SSC-K code features a multiple-channel core representation coupled with a point kinetics model with reactivity feedback. It provides a detailed, one-dimensional thermal-hydraulic simulation of the primary and secondary sodium coolant circuits, as well as the balance-of-plant steam/water circuit. Recently a two-dimensional hot pool model was incorporated into SSC-K for analysis of thermal stratification phenomena in the hot pool. In addition, SSC-K contains detailed models for the passive decay heat removal system and a generalized plant control system. The SSC-K code has also been applied to the computational engine for an interactive simulation of the KALIMER plant. This paper presents an overview of the recent activities concerned with SSC-K code model development This paper focuses on both descriptions of the newly adopted thermal hydraulic and neutronic models, and applications to KALIMER analyses for typical anticipated transients without scram.

  • PDF

Analysis of Induction Motor-pump System Supplied by a Photovoltaic Generator for Agricultural Irrigation in Southeastern Anatolian Region of Turkey

  • Gumus, Bilal;Yakut, Yurdagul Bentesen
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.777-785
    • /
    • 2015
  • In agricultural systems, significant amount of energy is consumed during irrigation periods. Therefore operating irrigation systems with electrical energy produced by solar energy is very important. It is be possible to operate irrigation systems which have small-pump power like drip-irrigation with electrical energy produced by solar energy. Electrical energy produced by photovoltaic panels can vary from the estimated value due to environmental factors. Consequently analysis of a real system's performance is important. Thus, more correct projections can be made for the systems which will be designed. In this study, induction motor-pump mechanism for drip-irrigation system is operated with photovoltaic generator. Solar energy capacity of the established system is evaluated by measurements in irrigation periods. By means of simulations, power values produced by system and gained from the actual system are compared. Additionally the performance of induction motor is analyzed with the help of the driver system that increases the efficiency and controls the motor. As regards of results, design values of the drip-irrigation systems fed with solar energy in Southeastern Anatolian Regions of Turkey are obtained. Performance results of induction motor controlled with driver are also provided.

A Study on the Performance of Blind type Double-Skin Facade System with PV modules (PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구)

  • Jo, Hye-Jin;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

Economic Analysis and Energy Saving Evaluation for Smart Grid System of Hospital Building (병원건물의 스마트그리드시스템의 에너지절약평가 및 경제성분석)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.129-139
    • /
    • 2010
  • This paper presents a basic energy performance data of microturbine, renewable Energy(BIPV and Solar Collector System) and a hybrid energy system(geothermal system and microturbine) installed in hospital building. The efficiency of solar collector and BIPV system was 30[%], 10[%] individually, and lower than micro turbines. Finally, in energy performance aspect, microturbine and geothermal source heat pump system were a high-efficiency system in hospital building. It is confirmed hybrid energy systems also show the most powerful alternative energy system for green hospital building from the simulation results.

An Analysis of Comparison between the Evaluation Tool for Building Energy Efficiency Rating System and Detailed Analysis Programs (건물에너지효율등급 평가도구와 상세해석프로그램의 비교 분석)

  • Lee, Jae-Hyuk;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.3-8
    • /
    • 2009
  • Since 2001, the Building Energy Efficiency Rating and Certification System have been implemented in Korea. For rating the energy efficiency performance, the evaluation tool for Building Energy Efficiency Rating System has been used. In this study, the evaluation tool was compared with detailed analysis programs(Trnsys 16, ESP-r) through simulations of heating energy needs for apartment, and we checked the character of the evaluation tool.

  • PDF

A Preliminary Study on the Analysis Model of Energy System based on Fuel Cell for Apartment Houses (연료전지기반 공동주택 에너지시스템 분석모델에 관한 기초연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.396-401
    • /
    • 2003
  • In the present study, preliminary investigation were carried out by analysis of energy system(heat and electricity) based on phosphoric acid fuel-cell of 50 kW for eco-apartment houses. Analysis model were consisted of fuel cell energy system, secondary energy unit and residential building of 5 stories with 20 and 40 households. And the investigation results reviewed under load pattern of heat and electric power of the apartment houses. The results showed mismatch between the needed heat load pattern and output of fuel cell energy system. The mismatch rate were assessed about 10-180% of heat load for apartment houses with season. We found that secondary energy unit are needed in order to supply insufficient heat.

  • PDF