• 제목/요약/키워드: Energy spectrometer

검색결과 497건 처리시간 0.026초

Design of a Beam-coupling System for a Chip-integrated Spectrometer with a Discrete Linear Waveguide

  • Liu, Zhiying;Jiang, Xin;Li, Mingyu
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.229-237
    • /
    • 2020
  • In this study, a beam-coupling system is designed to improve the coupling efficiency of achip-integrated spectrometer when the waveguide is arranged in a linear and discrete manner. In the proposed system the beam is shaped to be anti-Gaussian, to deposit adequate energy in the edge waveguides. The beam is discretely coupled to the corresponding waveguide by a microlens array, to improve the coupling efficiency, and is compressed by a toroidal lens to match the linear discrete waveguides. Based on the findings of this study, the coupling efficiency of the spectrometer is shown to increase by a factor of 2.57. Accordingly, this study provides a reference basis for the improvement of the coupling efficiency of other similar spectrometers.

수용액 환경에서 수은 측정을 위한 로다민 기반의 광섬유 센서 개발 (Development of Rhodamine-Based Fiber Optic Sensor for Detection of Mercury in Aqueous Environments)

  • 이애리;김용일;김범규;박병기
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.173-177
    • /
    • 2014
  • A Rhodamine-based fiber-optic sensor has been developed to detect mercury ions in aqueous environments. The fiber-optic sensor was composed of a mercury-sensing thin film, plastic optical fibers, and a spectrometer. The mercury-sensing thin film with the synthesized Rhodamine derivatives was fabricated with Sol-Gel process. A light emitted by a light source is guided by plastic optical fibers into the thin film in an aqueous solution and a reflected light is analyzed with the spectrometer. The experiment exhibits that an absorbance in the thin film is increased as mercury concentration is increased in the solution and the absorbance by mercury is higher than that by other heavy metals. The fiber-optic sensor exhibits high chromogenic phenomenon of mercury ions among various heavy metals and the correlation between absorbance and mercury concentration in the aqueous environments.

액상 광촉매 졸의 밴드갭 에너지 측정 연구 (A study on the Band Gap Energy Measurement of Liquid Phase Photocatalytic Sols)

  • 윤초롱;;오효진;황종선;김선재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.39-42
    • /
    • 2006
  • Titania sols or powders were are very promising materials for environment as photocatalyst. The band gap energy of $TiO_2$ has been known to be 2.8 to 3.2 eV. But the measuring system of its band gap is usually depend on absorption properties. Thus, in this study, absorption properties of $TiO_2$ sols prepared by hydrothermal process were researched with the effect of various particle sizes and concentrations. The mean particle size in $TiO_2$ sols increased as 15 nm to 60 nm, absorption graph measured by UV-Vis spectrometer shows to move red-shift. When dilute solution added with $2^n$ in $TiO_2$, the band gap energy increases as linear function.

  • PDF

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

중국산 해포석 내 석면 함유 유무 분석 (Asbestos Analysis of China Sepiolite by Transmission Electron Microscopy)

  • 송세욱;정용현;한정희
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.205-211
    • /
    • 2013
  • Objectives: 21 sepiolite substances produced in China were investigated for the presence of asbestos in their materials. Materials and methods: In order to identify asbestos in sepiolite substances, test materials were analyzed using a transmission electron microscope equipped with energy dispersive X-ray spectrometer (TEM-EDS) for confirming their shape and components (atomic %). Results: Five of 21 sepiolte substances were asbestos-containing materials. Two chrysotile containing sepiolite proved to be asbestoscontaining materials, as did two chrysotile mixed with tremolite containing sepiolite. 16 sepiolite substances did not contain asbestos materials. Conclusions: When importing sepiolite substances, they must be analyzed to determine if there is asbestos in their materials.

EPMA의 지질학(地質學)에의 응용(應用) (The Application of Electron Microprobe Analysis in Geological Science)

  • 상기남
    • 자원환경지질
    • /
    • 제17권4호
    • /
    • pp.315-320
    • /
    • 1984
  • The newly discovered minerals found during 30 years have been discovered with election microprobe analysis, and several other new minerals have been described largely on the basis of probe analysis. Widely used types of instrument are the wavelength dispersive spectrometer (WDS) and the energy dispersive Spectrometer (EDS), with emitted X-ray dispersed by a curved crystal that is arranged to satisfy the Bragg equation ($n{\lambda}=2dsin{\theta}$). Atomic Nos of Z 4 to 92 can be analyzed quantitatively if they present in amount exceeding 50~100ppm. The application of the microprobe in mineralogical and geological research is quantitative chemical analysis of grains as small as a few microns in diameter, individual grains in a rock or can be analyzed in thin section and polished section, analysis can be made comparatively short time, methods in non-destructure, to photographical and crystallographical information. This paper was written in order to document data evaluation procedure for quantitative energy dispersive election probe analysis.

  • PDF

한국산 석면의 산 용해도 평가 연구 (Assessment of Acid Solubility Test on Korean Asbestos by Transmission Electron Microscope Equipped with Energy Dispersive X-ray Spectrometer)

  • 정용현;한정희
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.146-151
    • /
    • 2014
  • Objectives: Chrysotile is mineralogically distinct from amphiboles, displaying a notably different chemical structure. The thin sheets that form chrysotile fiber lead to the ability of the lung/macrophage system to decompose the chrysotile fibers. This study was performed in order to compare the physicochemical characteristics of Korean asbestos with those of Canadian amphiboles. Materials: An acid solubility test for each test substance was done to compare pH 4.5 and pH 1.2 distilled water. Asbestos fibers which had been placed in acid solutions for five days, five weeks and weeks were analyzed with a transmission electron microscope equipped with an energy dispersive X-ray spectrometer (TEM-EDS). Results: The composition element (Mg) of Korean chrysotile, Korean anthophyllite and Canadian amosite significantly decreased from 5 days and also decreased significantly after 5 weeks and 10 weeks. Only the composition (Mg) of Canadian crocidolite did not change under any conditions. From 5 days, the Mg of Korean chrysotile, Korean anthophyllite and Canadian amosite were significantly lower than before the acid treatment, but there were no changes over time or by the pH of the acid solutions. Particularly after 10 weeks, the composition (Mg) of Korean chrysotile in the pH 1.2 acid solution showed a rapid reduction of 15.86%. Conclusions: Korean chrysotile was very weak in an acid environment, beginning to show significant changes after 5 days. The Mg component rapidly decreased after 10 weeks in the pH 1.2 acid solution.

46-MeV 전자선형가속기의 TOF 방법을 이용한 탄탈의 중성자 공명 에너지 분석에 관한 연구 (A Study on Neutron Resonance Energy of Tantalum by 46-MeV Electron Linac TOF Method)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.245-249
    • /
    • 2013
  • 천연 탄탈의 중성자포획에 의한 공명에너지를 측정하기 위하여 교토대학의 원자로연구소의 46-MeV 전자선형가속기의 광핵반응에서 발생하는 중성자를 이용하였다. 중성자포획에서 발생되는 즉발감마선을 BGO($Bi_4Ge_3O_{12}$)섬광검출장치로 측정하였다. 검출장치는 탄탈 시료에서 발생되는 즉발감마선을 기하학적으로 모두 측정하도록 만들어져 있으며 측정되어진 전기적 신호를 탄탈의 중성자 공명에너지 동정하는 스펙트럼구성에 사용하였다. 연구에서 사용되어진 중성자의 에너지는 1 ~ 200 eV 영역에 대하여 각각의 공명에너지를 분석하였다. 중성자에너지 측정은 중성자 비행시간법(TOF: Time-of-Flight)을 통하여 측정하였다. 광핵반응을 통한 중성자발생에서는 고에너지영역에서 강한 제동복사선이 발생하므로 수 keV영역 이하 영역의 중성자에너지에 대해서만 중성자공명을 측정하였다. 얻어진 Ta에 대한 중성자 포획 공명에너지 측정결과는 이전의 실험에 의한 측정 결과들 및 ENDF/B-VI와 Mughabghab의 평가된 값들과 비교 및 검토를 하였다. 측정되어진 공명들은 4.28 eV에서 거대 공명들을 측정하였고 그 이상의 에너지 영역의 다른 공명들도 이론에 의해서 계산되어진 값들과 비교하였다. 144.3 eV를 제외한 공명들은 평가값들과 거의 일치하는 경향을 보였다.

Calibration of HEPD on KOMPSAT-1 Using the KCCH Cyclotron

  • Shin, Young-Hoon;Rhee, Jin-Geun;Min, Kyoung-Wook;Lee, Chun-Sik;Lee, Ju-Hahn;Kwon, Young-Kwan;Kim, Jong-Chan;Ha, Jang-Ho;Park, Se-Hwan;Lee, Chang-Hack;Park, H.S.;Kim, Young-Kyun;Chai, Jong-Seo;Kim, Yu-Seong;Lee, Hye-Young
    • 대한원격탐사학회지
    • /
    • 제15권4호
    • /
    • pp.289-295
    • /
    • 1999
  • Space Physics Sensor (SPS) on-board the KOMPSAT-1 consists of the High Energy Particle Detector (HEPD) and the Ionospheric Measurement Sensor (IMS). The HEPD is to characterize the low altitude high energy particle environment and the effects on the microelectronics due to these high energy particles. It is composed of four sensors: Proton and Electron Spectrometer(PES), Linear Energy Transfer Spectrometer (LET), Total Dose Monitor (TDM), and Single Event Monitor (SEM). 35 MeV proton beam from the medical KCCH cyclotron, at Korea Cancer Center Hospital in Seoul, is used to calibrate the PES. Primary proton beam of 35MeV scattered by polypropylene target is converted to various energy protons according to the elastic collision kinematics. In this calibration, the threshold level of the proton in the PES can be determined and the energy ranges of PES channels are also calibrated.

투과율의 측정 및 이를 이용한 복사물성치의 계산 (Measurements of Transmittances and Calculations of Fundamental Radiative Properties)

  • 황용하;박승호;이영수
    • 태양에너지
    • /
    • 제14권2호
    • /
    • pp.29-37
    • /
    • 1994
  • 본 연구에서는 다공성 물질을 이용한 공기용 태양열 집열기에서 사용될 수 있는 유리덮개 및 다공성 매질의 파장에 따른 투과율(transmittance)을 UV-visible spectrophotometer및 FT-IR spectrometer을 이용하여 측정하였다. 유리의 경우에는 전자기 이론으로 유도된 투과율과 실험적 투과율을 비교하여 유리의 복소굴절율(complex refractive index)을 구하였다. 또한 분산이론(classical dispersion theory)으로부터 구한 이론적 복소굴절율과 비교하였다. 다공성 매질은 15 메쉬의 stainless steel wire screen을 여러 겹으로 겹쳐 이에 대한 투과율을 측정하였다. 그리고 two-flux모델을 사용하여 흡수계수(absorption coefficient) 및 후면산란 계수(backscattering coefficient)를 구하였다.

  • PDF