• Title/Summary/Keyword: Energy safety

Search Result 4,577, Processing Time 0.029 seconds

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Physicochemical Properties of Jadeite Powder and Its Application to Cosmetic Formulations (경옥가루의 물리화학적 특성 및 화장품 제형 응용 연구)

  • Kim, Kyoung Mi;Kim, Yong Woo;Hong, In Gi;Park, Soo Nam
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.81-96
    • /
    • 2018
  • In this study, physicochemical properties of the natural jadeite powder were investigated and also the wash-off pack and liquid foundation containing the jadeite powder were prepared. In addition, each of these formulations was evaluated by various functional effects, sensory evaluation, stability and skin safety. In the wash-off pack, the far-infrared ray emissivity and radiation energy values increased as a function of the jadeite powder content. At a 3% jadeite powder content, the skin temperature increased by about $0.5^{\circ}C$ when the jadeite powder-containing formulation was applied to the skin. Besides, the chroma of the liquid foundation containing the jadeite powder more clearly expressed the original color of the skin. Moisture content measurements of the wash-off pack and liquid foundation containing the jadeite powder showed the highest moisture uptake of 5.0% and 63.0%, respectively. In sensorial test, the wash-off pack formulations containing the jadeite powder demonstrated improved affinities toward a skin, adherency, and moistness and combatted itching. The liquid foundation containing jadeite powder showed also improved affinities except for the coverage when compared to control formulations. Furthermore, the stability evaluation for 8 weeks revealed neither discoloration nor separation phenomenon for the formulations containing the jadeite powder. Moreover, the pH was found to be stable up to 8 weeks and the viscosity up to 4 weeks. Skin safety assessments showed that all formulations containing the jadeite powder were non-irritating. These results suggest that the jadeite powder as an inorganic pigment may serve as a new multi-functional cosmetic ingredient with stability and safety.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

An Analysis of Accessibility to Hydrogen Charging Stations in Seoul Based on Location-Allocation Models (입지배분모형 기반의 서울시 수소충전소 접근성 분석)

  • Sang-Gyoon Kim;Jong-Seok Won;Yong-Beom Pyeon;Min-Kyung Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.339-350
    • /
    • 2024
  • Purpose: This study analyzes accessibility of 10 hydrogen charging stations in Seoul and identifies areas that were difficult to access. The purpose is to re-analyze accessibility by adding a new location in terms of equity and safety of location placement, and then draw implications by comparing the improvement effects. Method: By applying the location-allocation model and the service area model based on network analysis of the ArcGIS program, areas with weak access were identified. The location selection method applied the 'Minimize Facilities' method in consideration of the need for rapid arrival to insufficient hydrogen charging stations. The limit distance for arrival within a specific time was analyzed by applying the average vehicle traffic speed(23.1km/h, Seoul Open Data Square) in 2022 to three categories: 3,850m(10minutes), 5,775m(15minutes), 7,700m(20minutes). In order to minimize conflicts over the installation of hydrogen charging stations, special standards of the Ministry of Trade, Industry and Energy applied to derive candidate sites for additional installation of hydrogen charging stations among existing gas stations and LPG/CNG charging stations. Result: As a result of the analysis, it was confirmed that accessibility was significantly improved by installing 5 new hydrogen charging stations at relatively safe gas stations and LPG/CNG charging stations in areas where access to the existing 10 hydrogen charging stations is weak within 20 minutes. Nevertheless, it was found that there are still areas where access remains difficult. Conclusion: The location allocation model is used to identify areas where access to hydrogen charging stations is difficult and prioritize installation, decision-making to select locations for hydrogen charging stations based on scientific evidence can be supported.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Study on Environmental Hazards of Alternatives for PFOS (PFOS 대체물질의 환경유해성에 관한 연구)

  • Choi, Bong-In;Chung, Seon-Yong;Na, Suk-Hyun;Shin, Dong-Soo;Ryu, Byung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.317-322
    • /
    • 2016
  • While PFOS sodium salt ($C_8F_{17}SO_3Na$) was not degraded by microorganisms for 28 days, the 4 alternatives were biodegraded at the rates of 21.6% for $C_{25}F_{17}H_{32}S_3O_{13}Na_3$, 20.5% for $C_{15}F_9H_{21}S_2O_8Na_2$, 15.8% for $C_{23}F_{18}H_{28}S_2O_8Na_2$ and 6.4% for $C_{17}F_9H_{25}S_2O_8Na_2$, respectively. The acute toxicity test using Daphnia magna was conducted for 48 hours, the half effective concentration ($EC_{50}$) of PFOS sodium salt ($C_8F_{17}SO_3Na$) was evaluated in 54.5 mg/L. While the 4 alternatives did not show any effect at 500.0 mg/L. The surface tension of the PFOS salt ($C_8F_{17}SO_3Na$) is 46.2 mN/m at a concentration of 500.0 mg/L. While the surface tension of the 4 alternatives was found to be superior to PFOS sodium salt ($C_8F_{17}SO_3Na$). The surface tension of $C_{23}F_{18}H_{28}S_2O_8Na_2$ (20.9 mN/m) has the lowest, followed by $C_{15}F_9H_{21}S_2O_8Na_2$ (23.4 mN/m), $C_{17}F_9H_{25}S_2O_8Na_2$ (27.3 mN/m), $C_{25}F_{17}H_{32}S_3O_{13}Na_3$ (28.2 mN/m). The four kinds of alternatives ($C_{15}F_9H_{21}S_2O_8Na_2$, $C_{17}F_9H_{25}S_2O_8Na_2$, $C_{23}F_{18}H_{28}S_2O_8Na_2$, $C_{25}F_{17}H_{32}S_3O_{13}Na_3$) were found to be superior to PFOS sodium salt ($C_8F_{17}SO_3Na$) in terms of biodegradation, Daphnia sp. acute toxicity and surface tension, and thus they were considered applicable as PFOS alternatives. Especially biodegradation rate of $C_{15}F_9H_{21}S_2O_8Na_2$, $C_{23}F_{18}H_{28}S_2O_8Na_2$ and $C_{25}F_{17}H_{32}S_3O_{13}Na_3$ was relatively high as 15.8~21.6%, and Daphnia sp. acute toxicity and surface tension were considerably superior (surface tension 39~55%) to PFOS sodium salt. Therefore, these alternatives are considered to be available as an alternative of PFOS.

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Catalytic Oxidation of Aromatic Compounds over Spent Ni-Mo and Spent Co-Mo based Catalysts: Effect of Physico-chemical Pretreatments (폐 Ni-Mo 및 폐 Co-Mo계 촉매상에서 방향족 화합물의 촉매산화: 물리화학적 전처리 효과)

  • Shim, Wang Geun;Kang, Ung Il;Kim, Chai
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2010
  • Transition metal based spent catalysts (Ni-Mo and Co-Mo), which were scrapped from the petrochemical industry, were reused for the removal processes of volatile organic compounds (VOCs). Especially the optimum regeneration procedures were determined using the removal efficiency of VOCs. In this work, the spent Ni-Mo and spent Co-Mo catalysts were pretreated with different physic-chemical treatment procedure: 1) acid aqueous solution, 2) alkali solution, 3) chemical agent and 4) steam. The various characterization methods of spent and its regenerated catalysts were performed using nitrogen adsorption, X-ray diffraction (XRD) and scanning electron microscopy (SEM) equipped with an energy dispersive spectrometry (EDS). It was found that all spent catalysts were found to be potentially applicable catalysts for catalytic oxidation of benzene. The experimental results also indicated that among the employed physico-chemical pretreatment methods, the oxalic acid aqueous (0.1 N, $C_2H_2O_4$) pretreatment appeared to be the most efficient in increasing the catalytic activity, although the catalytic activity of spent Ni-Mo and spent Co-Mo catalysts in the oxidation of benzene were greatly dependent on the pretreatment conditions. The pretreated spent catalysts at optimum condition could be also applied for removing other aromatic compounds (Toluene/Xylene).

Relationship Between Modified Physiological Cost Index for Isokinetic Ergometer Exercise Test and Oxygen Consumption (등속성 에르고미터 운동을 이용한 수정된 생리적 부담 지수와 산소소비량 변화량과의 상관성)

  • Park, Ho-Joon;Cho, Sang-Hyun;Yi, Chung-Hwi;Park, Jung-Mi
    • Physical Therapy Korea
    • /
    • v.7 no.2
    • /
    • pp.20-34
    • /
    • 2000
  • The purpose of this study was to establish modified physiological cost index (PCI) for predicting energy consumption by heart rate (HR) at isokinetic ergometer exercise testing. The subjects were twenty-eight healthy men in their twenties. All of them performed upper and lower extremity isokinetic ergometer exercise tests which had six loads (400, 500, 600, 700, 800, and 900 kg-m/min) and five loads (400, 500, 600, 700, and 800 kg-m/min) respectively. The exercise sessions were finished when HR was in plateau. HR and oxygen consumption were determined during the final minute. Resting heart rate and oxygen consumption were used for calculating heart rate, oxygen consumption changes and modified PCI. Regression analysis established the relationship between each variable to work load, HR and oxygen consumption. The results were as follows: 1) In the lower extremity ergometer exercise test, oxygen consumption increased continuously as work load increased, but in the upper extremity ergometer test, oxygen consumption only increased until work load was 700 kg-m/min. 2) HR increased as work load increased in both exercise tests, but in the upper extremity ergometer test, HR decreased from the 700 kg-m/min. 3) The modified PCI increased as work load mcreased until the 700 kg-m/min point in the lower extremity ergometer test and until the 500 kg-m/min point in the upper extremity ergometer test when it started to decrease in both tests. 4) In the lower extremity ergometer exercise test, regression analysis established the relation as $dVO_2$ = -.0215HR - .2141 where $dVO_2$ is given in l/min and HR in beat/min ($R^2$ = .2677, p = .000). ln the upper extremity ergometer exercise test. regression analysis established the relation as $dVO_2$ = -.0115HR + .2746 ($R^2$ = .1308, p = .000). The results of this study were similar to previous studies but were different under high work load conditions. So modified PCI should be used with only low intensity work load testing. Subjects for upper extremity ergometer exercise testing should complete a prescribed training course prior to testing, and only low intensity work load should be used for safety considerations.

  • PDF

A Study on the Job Stress of Opticians (안경사 직무스트레스에 관한 연구)

  • Hwang, Hae-Young;Kim, Hyun-Mok;Kim, In-Soo;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: This study is conducted to evaluate the job stressors for opticians in Ulsan city. Methods: We investigated job stress of 180 opticians working in Ulsan. The results of this study from The Korean standard job stressors assessment tool developed by Korea occupational safety and health agency (KOSHA) was compared with Korean reference value. The questionnaire on the social, demographic characteristics of opticians was also used to find the factors affecting to job stressors by using multiple linear regression analysis. Results: Among the eight fields of stressors, the interpersonal conflict (the median value; 33.4, the measurements; men; 38.8, women; 41.5) and company culture (the median; 41.7, the measurements; men; 47.4, women; 49.3) were higher than the median value of the Korean workers. By multiple linear regression analysis, the significant factors to the interpersonal conflict were the duty, working hours, unmarried, average salary. In terms of the company culture, last school, rest day of month, job career, average salary and working hours were significantly associated to the score of company culture. Conclusions: Based on the results, important factor in the formation of a positive organizational culture through to improve treatment of opticians investigation and mutual horizontal communication systems in the workplace for the manage on interpersonal conflict and company culture.