• Title/Summary/Keyword: Energy safety

Search Result 4,577, Processing Time 0.037 seconds

Pressure loss coefficient measurements of pyrostarter filters (파이로스타터용 필터 압력손실계수 측정)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.126-133
    • /
    • 2007
  • An experimental apparatus has been designed and prepared in order to measure a pressure loss coefficient of hydropneumatic components, which is an important parameter in a hydropneumatic system Blow-down system has been adopted for the experimental apparatu to meet the high flow energy requirement as well as the apparatus safety. Especially, pressure loss coefficient measurements of pyrostarter filters have been performed and the pressure loss coefficient, K of CQSF has been experimentally acquired. Then it is shown that the turbine inlet pressure $p_2$, which is predicted from the measured K, is in accord with the results of combustion tests. Moreover, the relation between K and combustion pressure $p_0$ has been presented and it is disclosed that the relation accords well with the results of combustion tests. It is anticipated that K of a filter could play a role in PS size reduction by rising up the combustion pressure resulting in increasing the burning rate of solid propellant.

  • PDF

DEVELOPMENT AND EVALUATION OF THE MUON TRIGGER DETECTOR USING A RESISTIVE PLATE CHAMBER

  • Park, Byeong-Hyeon;Kim, Yong-Kyun;Kang, Jeong-Soo;Kim, Young-Jin;Choi, Ihn-Jea;Kim, Chong;Hong, Byung-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • The PHENIX Experiment is the largest of the four experiments that have taken data at the Relativistic Heavy Ion Collider. PHENIX, the Pioneering High Energy Nuclear Interaction eXperiment, is designed specifically to measure direct probes of the collisions such as electrons, muons, and photons. The primary goal of PHENIX is to discover and study a new state of matter called the Quark-Gluon Plasma. Among many particles, muons coming from W-boson decay gives us key information to analyze the spin of proton. Resistive plate chambers are proposed as a suitable solution as a muon trigger because of their fast response and good time resolution, flexibility in signal readout, robustness and the relatively low cost of production. The RPC detectors for upgrade were assembled and their performances were evaluated. The procedure to make the detectors better was optimized and described in detail in this thesis. The code based on ROOT was written and by using this the performance of the detectors made was evaluated, and all of the modules for north muon arm met the criteria and installation at PHENIX completed in November 2009. As RPC detectors that we made showed fast response, capacity of covering wide area with a resonable price and good spatial resolution, this will give the opportunity for applications, such as diagnosis and customs inspection system.

The Effects of Maternal Heart Sound on the Weight, Physiologic Responses and Behavioral States of Premature Infants (산모의 심장소리가 미숙아의 체중, 생리적 반응 및 행동상태에 미치는 효과)

  • Yeum, Mi-Kyung;Ahn, Young-Mee;Seo, Hwa-Sook;Jun, Yong-Hoon
    • Child Health Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.211-219
    • /
    • 2010
  • Purpose: The study was done to measure the effects of maternal heart sound on body weight, physiologic reactions (heart rate [HR] and cortisol) and behavioral states of preterm infants. Methods: Thirty-five preterm infants were recruited from a neonatal intensive care unit at a university hospital. Institutional Review Board approval and informed consent were obtained. The infants were assigned to an experimental group (n=18) with an auditory stimulation for 7 days of life, a continuous delivery of maternal heart sound using MP3 attached inside the incubator, or to a control (n=17) without any auditory stimulation. The outcome variables, daily variations in weight, HR and behavioral states, and differences in cortisol were analyzed. Results: There were differences in variations of daily weights (F=3.431, p=.011) and in cortisol (t=3.184, p=.006) between groups, but no difference in variations of daily HR (F=0.331, p=.933) and behavioral states (F=1.842, p=.323). Conclusion: The findings support the safety of continuous maternal heart sound as no changes in HR and behavioral states occurred, and the efficacy as weight increased and cortisol decreased. This auditory simulation may lead to more efficient utilization of energy in preterm infants by consistently providing familiar sounds from intrauterine life and blocking noxious sounds from NICU environments.

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

Assess of Breakdown Characteristics about Environmentally Friendly Gases (친환경절연재의 절연성 평가)

  • Choi, Eun-Hyeok;Koo, Bon-Ho;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.96-100
    • /
    • 2009
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability and safety are being required. This paper compares breakdown characteristics in $SF_6$ gas with $N_2/O_2$ Mixture gas($N_2:O_2=100$ : 0, 79 : 21, 60 : 40, 40 : 60) as using widely in High Voltage insulation equipment with the characteristics in different media which are focused on environmentally friendly gases. As an append result of research the results are fundamental data for electric insulation design of Distribution Power Facilities which will be studied and developed in the future. And we could make an environment friendly gas insulation material with mataining dielectric strength by $N_2/O_2$ Mixture gas which generates a lower lever of the global warming effect.

Magneto-rheological and passive damper combinations for seismic mitigation of building structures

  • Karunaratne, Nivithigala P.K.V.;Thambiratnam, David P.;Perera, Nimal J.
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1001-1025
    • /
    • 2016
  • Building structures generally have inherent low damping capability and hence are vulnerable to seismic excitations. Control devices therefore play a useful role in providing safety to building structures subject to seismic events. In recent years semi-active dampers have gained considerable attention as structural control devices in the building construction industry. Magneto-rheological (MR) damper, a type of semi-active damper has proven to be effective in seismic mitigation of building structures. MR dampers contain a controllable MR fluid whose rheological properties vary rapidly with the applied magnetic field. Although some research has been carried out on the use of MR dampers in building structures, optimal design of MR damper and combined use of MR and passive dampers for real scale buildings has hardly been investigated. This paper investigates the use of MR dampers and incorporating MR-passive damper combinations in building structures in order to achieve acceptable levels of seismic performance. In order to do so, it first develops the MR damper model by integrating control algorithms commonly used in MR damper modelling. The developed MR damper is then integrated in to the seismically excited structure as a time domain function. Linear and nonlinear structure models are evaluated in real time scenarios. Analyses are conducted to investigate the influence of location and number of devices on the seismic performance of the building structure. The findings of this paper provide information towards the design and construction of earthquake safe buildings with optimally employed MR dampers and MR-passive damper combinations.

Synthesis of polysulfone beads impregnated with Ca-sepiolite for phosphate removal

  • Hong, Seung-Hee;Lee, Chang-Gu;Jeong, Sanghyun;Park, Seong-Jik
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 2020
  • Former studies revealed that sepiolite thermally treated at high temperature have high adsorption capacity for phosphate. However, its micron size (75 ㎛) limits its application to water treatment. In this study, we synthesized sepiolite impregnated polysulfone (PSf) beads to separate it easily from an aqueous solution. PSf beads with different sepiolite ratios were synthesized and their efficiencies were compared. The PSf beads with 30% impregnated sepiolite (30SPL-PSf bead) possessed the optimum sepiolite ratio for phosphate removal. Kinetic, equilibrium, and thermodynamic adsorption experiments were performed using the 30SPL-PSf bead. Equilibrium adsorption was achieved in 24 h, and the pseudo-first-order model was suitable for describing the phosphate adsorption at different reaction times. The Langmuir model was appropriate for describing the phosphate adsorption onto the 30SPL-PSf bead, and the maximum adsorption capacity of the 30SPL-PSf bead obtained from the model was 24.48 mg-PO4/g. Enthalpy and entropy increased during the phosphate adsorption onto the 30SPL-PSf bead, and Gibb's free energy at 35 ℃ was negative. An increase in the solution pH from 3 to 11 induced a decrease in the phosphate adsorption amount from 27.30 mg-PO4/g to 21.54 mg-PO4/g. The competitive anion influenced the phosphate adsorption onto the 30SPL-PSf bead was in the order of NO3- > SO42- > HCO3-. The phosphate breakthrough from the column packed with the 30SPL-PSf bead began after ~2000 min, reaching the influent concentration after ~8000 min. The adsorption amounts per unit mass of 30SPL-PSf and removal efficiency were 0.775 mg-PO4/g and 61.6%, respectively. This study demonstrates the adequate performance of 30SPL-PSf beads as a filter for phosphate removal from aqueous solutions.

Design of Bottom Shape and Forming Analysis of Hydrogen Pressure Vessel with Maximum Volume (최대 내용적을 갖는 수소압력용기의 형상설계 및 성형해석)

  • Park, Gun Young;Kwak, Hyo Seo;Lee, Kwang O;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.941-948
    • /
    • 2017
  • Recently, hydrogen energy has been in the spotlight as an alternative to diminishing fossil fuels and as a potential solution to environmental pollution. The development of hydrogen-fueled vehicles and the demands for improved fuel efficiencies have resulted in the need to increase the volume of the hydrogen pressure vessels. Pressure vessels having an elliptical bottom, as opposed to one that is hemispherical, allow for a greater capacity. However, there are insufficient studies on the feasibility of the forming process required for an elliptical bottom. In this study, the liner capacity is calculated according to the ratios of the major to the minor axes of the elliptical bottom part in a hydrogen pressure vessel. Structural safety is verified through finite element analyses, and the results are compared to the theoretical results. The feasibility of the proposed elliptical shape of the pressure vessel bottom, while filled to maximum capacity, is validated through forming analysis.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • v.26 no.6
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Distribution of Suspended Clay Minerals around the Kori Waters (고리 부근 현탁물중 점토광물의 분포에 관한 연구)

  • Kim Dae-Choul;Kim Jung-Moo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.23 no.2
    • /
    • pp.145-154
    • /
    • 1990
  • Amounts of total suspended matter(TSM) around the Kori waters have been monitored for two years to understand the dispersal pattern of fine-grained sediment. Average concentration of the TSM is $3\~4\;mg/\iota$ in the surface and $3.5\~5\;mg/\iota$ in the near-bottom water. Semi-quantitative analysis for the four major clay minerals in TSM is also performed. The average relative abundance of each clay mineral such as illite, kaolinite, chlorite, and smectite is $65\%,\;17\%,\;17\%$, and $1\%$, respectively. It seems that the majority of recent fine-grained sediment deposited around the Kori area is derived from the Nakdong River. The texture of surface sediment is also dominated by fine-grained fraction leading up to $90\%$ of silt and clay content. The grain size decreases seaward progressively.

  • PDF