• 제목/요약/키워드: Energy safety

검색결과 4,498건 처리시간 0.037초

Experimental measurement of stiffness coefficient of high-temperature graphite pebble fuel elements in helium at high temperatures

  • Minghao Si;Nan Gui;Yanfei Sun;Xingtuan Yang;Jiyuan Tu;Shengyao Jiang
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1679-1686
    • /
    • 2024
  • Graphite material plays an important role in nuclear reactors especially the high-temperature gas-cooled reactors (HTGRs) by its outstanding comprehensive nuclear properties. The structural integrity of graphite pebble fuel elements is the first barrier to core safety under any circumstances. The correct knowledge of the stiffness coefficient of the graphite pebble fuel element inside the reactor's core is significant to ensure the valid design and inherent safety. In this research, a vertical extrusion device was set up to measure the stiffness coefficient of the graphite pebble fuel element by the Institute of Nuclear and New Energy Technology (INET) of Tsinghua University in China. The stiffness coefficient equations of graphite pebble fuel elements at different temperatures are given (in a helium atmosphere). The result first provides the data on the high-temperature stiffness coefficient of pebbles in helium gas. The result will be helpful for the engineering safety analysis of pebble-bed nuclear reactors.

A rapid modeling method and accuracy criteria for common-cause failures in Risk Monitor PSA model

  • Zhang, Bing;Chen, Shanqi;Lin, Zhixian;Wang, Shaoxuan;Wang, Zhen;Ge, Daochuan;Guo, Dingqing;Lin, Jian;Wang, Fang;Wang, Jin
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.103-110
    • /
    • 2021
  • In the development of a Risk Monitor probabilistic safety assessment (PSA) model from the basic PSA model of a nuclear power plant, the modeling of common-cause failure (CCF) is very important. At present, some approximate modeling methods are widely used, but there lacks criterion of modeling accuracy and error analysis. In this paper, aiming at ensuring the accuracy of risk assessment and minimizing the Risk Monitor PSA models size, we present three basic issues of CCF model resulted from the changes of a nuclear power plant configuration, put forward corresponding modeling methods, and derive accuracy criteria of CCF modeling based on minimum cut sets and risk indicators according to the requirements of risk monitoring. Finally, a nuclear power plant Risk Monitor PSA model is taken as an example to demonstrate the effectiveness of the proposed modeling method and accuracy criteria, and the application scope of the idea of this paper is also discussed.

PRELIMINARY SAFETY STUDY OF ENGINEERING-SCALE PYROPROCESS FACILITY

  • Moon, Seong-In;Chong, Won-Myung;You, Gil-Sung;Ku, Jeong-Hoe;Kim, Ho-Dong;Lim, Yong-Kyu;Chang, Hyeon-Sik
    • Nuclear Engineering and Technology
    • /
    • 제46권1호
    • /
    • pp.63-72
    • /
    • 2014
  • Pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems in Korea. The Korea Atomic Energy Research Institute has been studying pyroprocess technology, and the conceptual design of an engineering-scale pyroprocess facility, called the Advanced Fuel Cycle (AFC) facility, has been performed on the basis of a 10tHM throughput per year. In this paper, the concept of the AFC facility was introduced, and its safety evaluations were performed. For the safety evaluations, anticipated accident events were selected, and environmental safety analyses were conducted for the safety of the public and workers. In addition, basic radiation shielding safety analyses and criticality safety analyses were conducted. These preliminary safety studies will be used to specify the concept of safety systems for pyroprocess facilities, and to establish safety design policies and advance more definite safety designs.

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

A Safety Analysis of a Steam Generator Module Pipe Break for the SMART-P

  • Kim Hee Kyung;Chung Young-Jong;Yang Soo-Hyung;Kim Hee-Cheol;Zee Sung-Quun
    • International Journal of Safety
    • /
    • 제3권1호
    • /
    • pp.53-58
    • /
    • 2004
  • SMART-P is a promising advanced small and medium category nuclear power reactor. It is an integral type reactor with a sensible mixture of new innovative design features and proven technologies aimed at achieving a highly enhanced safety and improved economics. The enhancement of the safety and reliability is realized by incorporating inherent safety improving features and reliable passive safety systems. The improvement in the economics is achieved through a system simplification, and component modularization. Preliminary safety analyses on selected limiting accidents confirm that the inherent safety improving design characteristics and the safety system of SMART-P ensure the reactor's safety. SMART-P is an advanced integral pressurized water reactor. The purpose of this study is for the safety analysis of the steam generator module pipe break for the SMART-P. The integrity of the fuel rod is the major criteria of this analysis. As a result of this analysis, the safety of the RCS and the secondary system is guaranteed against the module pipe break of a steam generator of the SMART-P.