• Title/Summary/Keyword: Energy performance analysis

Search Result 4,219, Processing Time 0.045 seconds

Passive Heat Removal Characteristics of SMART

  • Seo, Jae-Kwang;Kang, Hyung-Seok;Yoon, Joo-Hyun;Kim, Hwan-Yeol;Cho, Bong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.623-628
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt thermal capacity named SMART (System-Integrated Modular Advanced Reactor) is currently under development in Korea Atomic Energy Research Institute (KAERI) for multi-purpose applications. Modular once-through steam generator (SG) and self-pressurizing pressurizer equipped with wet thermal insulator and cooler are essential components of the SMART. The SMART Provides safety systems such as Passive Residual Heat Removal System (PRHRS). In this study, a computer code for performance analysis of the PRHRS is developed by modeling relevant components and systems of the SMART. Using this computer code, a performance analysis of the PRHRS is performed in order to check whether the passive cooling concept using the PRHRS is feasible. The results of the analysis show that PRHRDS of the SMART has excellent passive heat removal characteristics.

  • PDF

Performance Evaluation of Solar Water Heating System Using Proof Test (태양열 온수기 실증연구를 통한 성능 평가)

  • Kim, Jae-Yeol;Kwac, Lee-Ku;Yang, Dong-Jo;Choi, Choul-Jun;Kim, Hong-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

Optimization Method for MEA Performance Considering the Non-Uniformity of Operating Condition in a Large-area Bipolar Plate (대면적 분리판의 운전 환경 불균일성을 고려한 MEA 성능최적화 방법)

  • Kim, Sungmin;Sohn, Young-Jun;Woo, Seunghee;Park, Seok-Hee;Jung, Namgee;Yim, Sung-Dae
    • New & Renewable Energy
    • /
    • v.17 no.2
    • /
    • pp.50-58
    • /
    • 2021
  • We proposed an MEA development methodology that accurately measures intrinsic MEA performance while considering the uneven reaction environments formed inside a large-area BP. To facilitate measurement of the inherent MEA performance, we miniaturized the active area of the MEA to 3 cm2, and prepared two MEAs with different ionomer contents of 0.65 and 0.80 (I/C). By simulating the operating conditions of a 100 cm2 BP at the inlet (I), center (C), and outlet (O), the oxygen concentration and relative humidity were determined to be 20.7, 13.8, 11.7%, and 50, 66.1, and 70.1% respectively. We measured the performance and electrochemical analysis of the prepared MEAs under the three simulated conditions. Based on the results of statistical analysis of the evaluated MEA performance data, I/C 0.65 MEA had a higher average performance and lower performance deviation than I/C 0.80 MEA. Hence, it can be concluded that an I/C 0.65 MEA is a more effective MEA for large-area BP. Based on the above research process, we confirmed the effectiveness of the proposed MEA development methodology.

Analysis of Induction Motor-pump System Supplied by a Photovoltaic Generator for Agricultural Irrigation in Southeastern Anatolian Region of Turkey

  • Gumus, Bilal;Yakut, Yurdagul Bentesen
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.777-785
    • /
    • 2015
  • In agricultural systems, significant amount of energy is consumed during irrigation periods. Therefore operating irrigation systems with electrical energy produced by solar energy is very important. It is be possible to operate irrigation systems which have small-pump power like drip-irrigation with electrical energy produced by solar energy. Electrical energy produced by photovoltaic panels can vary from the estimated value due to environmental factors. Consequently analysis of a real system's performance is important. Thus, more correct projections can be made for the systems which will be designed. In this study, induction motor-pump mechanism for drip-irrigation system is operated with photovoltaic generator. Solar energy capacity of the established system is evaluated by measurements in irrigation periods. By means of simulations, power values produced by system and gained from the actual system are compared. Additionally the performance of induction motor is analyzed with the help of the driver system that increases the efficiency and controls the motor. As regards of results, design values of the drip-irrigation systems fed with solar energy in Southeastern Anatolian Regions of Turkey are obtained. Performance results of induction motor controlled with driver are also provided.

Performance analysis of a 3 bladed & 5 bladed savonius rotor for wave energy conversion by CFD

  • Zullah, Mohammed Aisd;Prasad, Deepak;Choi, Young-Do;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.628-629
    • /
    • 2009
  • A variety of technologies have already been developed to capture energy from the ocean waves, this one is simple to construct. Rather then looking at the surface waves, the technique used lets the waters current beneath the waves directly drive the rotors. The novel ocean wave energy convertor consists of savonius rotor which is mounted in the ocillating water column (OWC) chamber. This study investigates the performance of a 3 blade and 5 bladed savonius rotor under same wave condition using commercial CFD code. Initially the performance analysis of savonius type turbine have been carried out with conventional three bladed curved rotors. From the experieneces of the simulations, 5 bladed savonius rotor have been developed and studied. Performace caracteristics of the 5 bladed savonius rotor has been evaluated and the results obgtained are comopared with the conventional three bladed curved rotors.

  • PDF

A study on internal flow characteristics and performance analysis of a micro hydro tubular turbine (소수력발전용 튜블러 수차의 내부유동특성 및 성능해석)

  • Lee, Seung-Yeob;Choi, Young-Do;Hwang, Young-Chul;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.606-609
    • /
    • 2009
  • Development of renewable energy is very important because of environmental problems caused by greenhouse effect. This is due to the use of fossil fuels which has serious consequences. Therefore, development of small hydropower can be a good countermeasure for the problems. The small hydropower is clean energy because the small hydropower generates few $CO_2$. Moreover, as the energy density by the small hydropower is high, it is economical for a society which wants to introduce the system. The purpose of this study is to improve the turbine performance. This study is about tubular-type hydro turbine among renewable energy that is based using the different water pressure level in pipe lines. The analysis was performed using the commercial CFD code ANSYS-CFX.

  • PDF

Thermal Performance Analysis of Compound Parabolic Collector (CPC) System Employing Storage Tank Through a Year (축열조를 채용한 복합 포물형 태양열 집열기(CPC) 시스템의 연중 열적 성능 해석)

  • LIM, SOK-KYU;JUNG, YOUNG GUAN;KIM, KYOUNG HOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.376-383
    • /
    • 2019
  • This paper presents of thermal performance analysis by using mathematical models for a compound parabolic collector (CPC) system employing heat storage tank. The thermal performance including insolation energy, heat loss from collector system, useful energy, collector efficiency, and temperature of storage tank were theoretically investigated through a year using monthly-average meteorological data at Seoul. The simulated results showed that the CPC systems are suitable for the applications of higher temperature than flat plate collector (FPC) systems.

A Study on the Space Boundary Information Interoperability Improvement of IFC Data for Building Energy Performance Assessment (IFC 데이터의 건물에너지 성능평가를 위한 공간경계정보 호환성 향상 연구)

  • Choi, Jungsik;Kim, Inhan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.129-137
    • /
    • 2014
  • Due to the increase of carbon dioxide and building regulations, BIM is considered a way of low-carbon and eco-friendly building development for its many advantages. The advantages can be maximized with Open BIM since it can produce optimal results for various purposes of energy performance assessment. However there are some problems in data interoperability in the process of Open-BIM based energy performance assessment. To solve such problems, this study focuses on space boundary information interoperability between IFC of Open BIM and IDF format of Energy Plus known as the most accurate and diverse energy performance assessment. The study analyzes the analogous study then figures out the problems of IFC based energy performance analysis, and suggests the way of interoperability. Finally, the development of automation program makes this way much more effective. The study of IFC data interoperability is useful for improving the reliability of Open-BIM based energy assessment.

Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System (주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구)

  • Kang, Eun-Chul;Min, Kyoung-Chon;Lee, Kwang-Seob;Lee, Euy-Joon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2016
  • Heat pump unit performance is represented by the COP(Coefficient of Performance) and expressed by the one point design condition according to KS C 9306. However, when heat pump operated to the real buildings, the simulations are changed continuously according to the actual weather conditions, the building load and heat pump source conditions. The purpose of this paper is to evaluate the APF(Annual performance factor) for a climate dependent building integrated air-to-air heat pump system in major cities in Korea. TRNSYS simulation tool with an international MV standard based IPMVP 4.4.2 was utilized to perform the annual performance analysis. The APF with the multi-performance data based method was calculated as 2.29 for Daejeon residential building case while Busan residential building case appeared as the highest with 2.36.

Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm (건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석)

  • Park, Sihun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.