• Title/Summary/Keyword: Energy performance analysis

Search Result 4,287, Processing Time 0.041 seconds

Analysis of Levelized Cost of Hydrogen and Financial Performance Risk by CCU System (CCU 시스템을 통한 균등화 수소원가 및 재무적 위험도 분석)

  • MINHEE SON;HEUNGKOO LEE;KYUNG NAM KIM
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.660-673
    • /
    • 2022
  • In achieving carbon neutrality and the hydrogen economy, the estimation of H2 cost is critical in terms of CCU technologies. This study analyzes LCOH of hydrogen produced by the carbon utilization unit with methane reforming and CO2 from thermal power plant. LCOH for H2 made with CO is estimated in three ways of Joint Cost Allocations with financial performance risk assessment. Regarding cost analysis, the zero value of LCOH is $6,003/ton. We found that the CCU technology has economic feasibility in terms of profitability. The sensitivity analysis result shows that the input ratio is more influential to the LCOH than other variables. Risk analysis presents the baseline price of zero value of LCOH - $8,408/ton, which is higher than the cost analysis - $6,003/ton. Mainly, the price variability of natural gas primarily affects the LCOH. The study has significant value in analyzing the financial performance risks as well as the cost of H2 produced by a Plasma-based CCU system.

Establishing a Energy Utilization Database for Energy Performance Evaluation of Multi-Family Housing using District Heating (지역난방 공동주택의 에너지 성능 평가를 위한 공동주택 단지별 에너지사용량 Database 구축)

  • Jeong, Jaewook;Hong, Taehoon;Ji, Changyoon;Leigh, Seung-Bok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.105-113
    • /
    • 2015
  • In order to evaluate the energy performance of buildings, it is important to determine reliable information of energy utilization during operating phase. It is also required to establish the database which have the amounts of population deducted by objective filtering and analysis. In this study, all energy sources were applied to evaluate synthetically the energy performance of Multi-Family Housings(MFH) using district heating and the amounts of population were obtained sufficiently through data searching in Seoul and neighbor cities. Finally the database of source energy utilization and $CO_2$ emission in 325 MFH complexes were established through cross validation between data sources and statistical analysis. Additionally, further ideas have been proposed to improve existing MFH Management Information System.

Investigation on Aerodynamic Performance of a Highly-Loaded Axial Fan with Active/Passive Flow Control Using FSI Analysis (유체-구조 연성해석을 이용한 능동/수동 유동제어방식이 결합된 고하중 축류 팬의 성능특성 연구)

  • Ma, Sang-Bum;Kim, Kwang-Yong;Choi, Jaeho;Lee, Wonsuk
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.1
    • /
    • pp.113-119
    • /
    • 2017
  • An investigation on aerodynamic performance of a highly-loaded axial fan has been conducted to find the effects of tip injection and casing groove on aerodynamic performance in this study. Three-dimensional Reynolds-averaged Navier-Stokes equations with $k-{\varepsilon}$ turbulence model were used to analyze the fluid flow in the fan with Fluid-Structure Interaction (FSI) analysis. The hexahedral grid was used to construct computational domain, and the grid dependency test drew the optimal grid system. FSI analysis was also carried out to predict the deformation of rotor and stator blades, and the effect of deformation on the aerodynamic performance of axial fan was analyzed compared to the performance predicted without FSI analysis.

TMY2 Weather data for Korea (TMY2 방식에 의한 국내 기상자료 작성 연구)

  • Shin, Kee-Shik;Yoon, Chang-Ryuel;Park, Sang-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.243-246
    • /
    • 2009
  • To evaluate the building energy performance, many building simulation programs are used and its capabilities are developed. Despite of its increased capabilities the weather data used In the Building Energy performance evaluation, are still using the same limited set of data. This often forces users to find or calculate weather data such as illuminance, solar radiation, and ground temperature from other sources to calculate it. Also, proper selection of a right weather data set has been considered as one of important factors for a successful building energy simulation. In this paper, we describe TMY2 data, a generalized weather data format developed for use, and applied to Seoul region and examine the differences comparing to existing weather data. A set of 23 years raw weather data base has been developed to provide the weather data file for building energy analysis in Seoul.

  • PDF

Survey and Analysis of Power Energy Usage of University Buildings (대학건축물의 전력에너지 사용량 조사 및 분석)

  • Youn, Nam Sik;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.27-32
    • /
    • 2013
  • For the past seven years, the increase in the energy consumption of universities in Korea has been 3.7 times higher than the overall increase in the energy consumption across Korea (22.5%). This is an example that shows that universities have been a massive source of greenhouse gases. Such an increase has been attributed to the new and expanded construction of architectural structures on campus. Many people argue that the increasing number of buildings may cause waste of energy and loss of efficiency. Therefore, this study was conducted as a preliminary study to derive energy efficiency measures for new university buildings. The two aspects of energy-saving as required by the eco-friendly structure certification standards have been applied to analyze the use of new/renewable energy and the energy consumption of new university buildings that have applied light density and light engineering methods. Based on these results, the major sources of energy of existing buildings and new university buildings were compared to comparatively discuss how effectively they improve energy performance.

A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety (건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

Steady-State Performance Analysis of Pressurizer and Helical Steam Generator for SMART

  • Seo, Jae-Kwang;Kang, Hyung-Seok;Kim, Hwan-Yeol;Cho, Bong-Hyun;Lee, Doo-Jeong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.310-315
    • /
    • 1997
  • System-Integrated Modular Advanced Reactor (SMART), where major primary components such as modular helical steam generator and self regulating pressurizer are integrated into reactor vessel, is currently under development. The pressurizer is designed to control the primary pressure mainly with partial pressure of nitrogen gas and to maintain the fluid temperature as low as possible for the purpose of minimizing steam contribution. The steam generator (SG) is designed to produce super-heated steam inside tube at power operation. Because the in-vessel pressurizer and in-vessel SG are classified as the characteristic components of SMART, it is important to perform a steady state calculation of these components in order to evaluate the adoption of these components. A steady state analysis of the in-vessel pressurizer and in-vessel SG has been performed under normal power operation and the results show an acceptable performance of the components.

  • PDF

Analysis of leakage factors affecting ECV performance in variable compressor

  • Mahmud, Md. Iqbal;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.183-188
    • /
    • 2014
  • Solenoid operated electromagnetic control valve (ECV) using in an external variable displacement swash plate type compressor is widely used for air conditioning control system because of its low energy consumption and high efficient characteristics. ECV controls the entire vehicle air conditioning system by means of a pulse width modulation (PWM) system that supplied from an external controller. Different pressure ports located within ECV has important functions to control the air/refrigerant flow through its internal passages. The flow paths are preciously maintained with acceptable ranges of leakage (gap) between the parts inside it which is followed by effective design and critical dimensioning of its internal features. Therefore, it saves energy losses from the solenoid operation as well as ensures the balance of forces within it. The research paper highlights analysis of the leakages (at different pressure ports) and dimensioning tolerance factors that affects the ECV performance.

An Analytical Study on Indoor Thermal Comfort Performance According to the Automatic Control of Internal-External Blind

  • Lee, Do-Hyung;Kim, Tae-Woo;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to analyse PMV (Predicted Mean Vote) and PPD (Predicted Percentage of dissatisfied) by automatic control of slat-type vertical blind. EnergyPlus, a building energy analysis software has been used for this study. The energy model is calibrated in Energy Plus using measured zone temperature and glass surface temperature data for one day and thermal comfort performance inside the building analysis was carried out. The calibrated data has the MBE of 4% and Cv(RMSE) of 10%. The result was that, for better zone thermal comfort, installation of blind on the outside is more appropriate than inside or no blind case. Additionally, different glazing types were compared and it was found that Triple Low-e glass is the most favorable.

Performance Analysis of an Energy Detection Based Cooperative Spectrum Sensing with a Single Threshold in the Presence of Noise Uncertainty (잡음 전력의 불확실성이 존재하는 환경에서 단일 임계값을 사용하는 에너지 검파 기반 협력 스펙트럼 감지의 성능 분석)

  • Lim, Chang Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1406-1411
    • /
    • 2012
  • An energy detection based spectrum sensing has been found to be vulnerable to the noise power uncertainty. A cooperative spectrum sensing with an energy detector has appeared as one of the solutions to alleviate this difficulty. However, its performance analysis in a fading environment has not been reported yet in the literature. Motivated by this, this paper presents the performance analysis of the scheme by extending our previous work on evaluating the performance of an energy detector in the presence of noise power uncertainty. The analysis shows that the false alarm probability and detection probability gets higher as the sensing time and/or the number of the secondary users in the OR based cooperative spectrum sensing scheme increase when the noise power uncertainty exists.