• 제목/요약/키워드: Energy meter

검색결과 362건 처리시간 0.026초

What Drives Residential Consumers Willingness to Use Green Technology Applications in Malaysia?

  • OTHMAN, Nor Salwati;HARUN, Nor Hamisham;ISHAK, Izzaamirah
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권10호
    • /
    • pp.269-283
    • /
    • 2021
  • The government policies and initiatives to guarantee sustainable energy and clean environmental conditions contributed to the introduction of green technology electricity appliances in the market. This study sought to determine the physiological and socio-economics-demographic factors driving residential electricity consumers to use green technology electricity appliances, mainly solar PV, smart meter, electric vehicle, and battery storage technology. By understanding consumer intention, the investors of solar PV, battery storage, electric vehicle, and smart meter can estimate the demand and upscale the market for the corresponding products. For that purpose, the intention to use the solar PV, smart meter, electric vehicle, and battery storage function is developed by utilizing the combination of the theory of planned behavior, technology acceptance, and reasoning action. A reliable and valid structured online questionnaire and stepwise multiple regression are used to identify the possible factors that drive consumer behavior intention. The results show that the social influence, knowledge on RE, and perceived price significantly influence residential consumers' willingness to adopt the technologies offered. The findings of this study suggest that the involvement of NGOs, public figures, and citizens' cooperation are all necessary to spread information about the government's objectives and support Malaysia's present energy and environmental policies.

국내 계통 특성을 고려한 IEC61000-4-15 Edition 2 기반의 디지털 플리커 미터 알고리즘 구현 및 평가 (Implementation and Performance Evaluation of Digital Flickermeter Algorithm According to IEC61000-4-15 Edition 2 for Korean Distribution Power System)

  • 신훈철;한수경;박상호;김건중;조수환
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1017-1024
    • /
    • 2017
  • The International Electrotechnical Commission(IEC) 61000-4-15 is a standard proposing techniques for a flicker meter test and measurement method. The IEC61000-4-15 ed1 announced in 1997 was not include tests for accurate verification. Also it was not explained flicker meter algorithm that can be directly applied to the other power systems. But the new edition of IEC61000-4-15 ed2 prescribes a variety of tests for verify flicker meter algorithm and it explains 'correction factor' used for measuring flicker in other power systems. It can measure flicker severity in 220V system by multiplying correction factor to the measured values with the 230V algorithm. This paper compared the method of measuring flicker severity in korea power system using the correction factor and the modified weighting filter, after verifying of digital flicker meter algorithm created by using matlab based on IEC61000-4-15 ed2.

분전반 전력관리용 지능형 계측 제어 시스템 개발 (A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel)

  • 박병철;박재성;송성근;신중린
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

첨단 검침 인프라에서 에너지 효율을 위한 기기 할당 방안 (The Device Allocation Method for Energy Efficiency in Advanced Metering Infrastructures)

  • 정성민
    • 디지털산업정보학회논문지
    • /
    • 제16권1호
    • /
    • pp.33-39
    • /
    • 2020
  • A smart grid is a next-generation power grid that can improve energy efficiency by applying information and communication technology to the general power grid. The smart grid makes it possible to exchange information about electricity production and consumption between electricity providers and consumers in real-time. Advanced metering infrastructure (AMI) is the core technology of the smart grid. The AMI provides two-way communication by installing a modem in an existing digital meter and typically include smart meters, data collection units, and meter data management systems. Because the AMI requires data collection units to control multiple smart meters, it is essential to ensure network availability under heavy network loads. If the load on the work done by the data collection unit is high, it is necessary to allocation new data collection units to ensure availability and improve energy efficiency. In this paper, we discuss the allocation scheme of data collection units for the energy efficiency of the AMI.

IMV를 사용한 유압굴삭기 붐 동작의 에너지 절감 (Energy Saving in Boom Motion of Excavators using IMV)

  • 허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권3호
    • /
    • pp.1-7
    • /
    • 2017
  • Energy consumption of conventional hydraulic excavators controlled by MCV is considerable when negative load is applied because the meter orifice and meter-out orifice are machined in one spool. Therefore, IMV is introduced to save energy use of hydraulic excavators, but existing hydraulic excavators have various advantages so it is difficult to make a clear comparison. In this study, we compare the use of an existing MCV excavator that has many advantages such as negative control, and IMV for boom up and down operation, and if IMV is used to save energy, we will examine the cause. If possible, for comparability under the same conditions, both systems use pressure balance valves to minimize power consumption when not using power in the actuator. The orifice area at each notch of each valve is calculated, and energy saving is verified by comparing the two systems through simulation.

수치해석을 이용한 평균 양방향 유동 튜브 유량계의 파울링 환경 적용성 연구 (Numerical Study of the Averaging BDFT(bidirectional flow tube) Flow Meter on the Applicability in the Fouling Condition)

  • 박종필;정지환;강경호;백원필;윤병조
    • 한국유체기계학회 논문집
    • /
    • 제16권4호
    • /
    • pp.35-43
    • /
    • 2013
  • Most of the nuclear power plants(NPPs) adopts pressure difference type flow meters such as venturi and orifice meters for the measurement of feedwater flow rates to calculate reactor thermal power. However, corrosion products in the feedwater deposits on the flow meter by fouling as operating time goes. These effects lead to severe errors in the flow indication and then determination of reactor thermal power. The averaging BDFT, which has developed by Yun et al., has a potentiality to minimize this problem thanks to its inherent measurement principle. Therefore, it is expected that the averaging BDFT can replace the venturi meter for the feedwater pipe of steam generator of NPPs. The present work compares the amplification factor, K, based on CFD calculation against the K obtained from experiments in order to confirm whether a commercial CFD code can be applicable to the evaluation of characteristic for the averaging BDFT. In addition to this, the simulations to take into account of fouling effect are also carried out by rough wall option. The results show that the averaging BDFT is a promising flow meter for the accurate measurement of flow rates in the fouling condition of the NPPs.

스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안 (Electric Power Energy Saving and Efficient Measures in Buildings using the Smart-Meter)

  • 황현배;정병수
    • 디지털융복합연구
    • /
    • 제12권11호
    • /
    • pp.365-372
    • /
    • 2014
  • 본 논문에서는 스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안에 대하여 실험하였다. 전력에너지 절감을 위해 개선된 자동역률제어시스템(APFC)을 제안하고, 수요전력의 억제(Demand Control) 방안을 제시하였다. 이는 스마트미터의 ICT 기술을 통하여 실시간 양방향으로 콘덴서 뱅킹과 차단기를 직접 제어함으로써 이루어진다. 개선된 APFC는 콘덴서 뱅킹을 보다 다양화하기 위해 이종 용량의 콘덴서를 직병렬 혼합 결선하여 구성함으로써 구축 비용을 최소화 한다. 상기 기능을 위해 Atmel사의 AVR465를 이용하여 PLC 및 Zigbee 통신기능을 갖는 스마트미터를 설계하였다. 24시간 운영되는 숙박시설에 대하여 테스트한 결과 역률은 95%이상을 유지하였고, 과보상은 발생하지 않았음을 확인할 수 있었다.

조파역내 오염물 이동특성 평가 실험 (Experiments for the Characteristic Evaluation of Pollutant Transport in Tidal Influenced Region)

  • 박건형;김기철;정성희;서경석
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.391-395
    • /
    • 2010
  • The characteristics for pollutant transport in tidal influenced area was investigated using tidal wave hydraulic scale model. Hydraulic scale model was composed of the tidal generator, attenuation area and channel. Also, wave height, current meter and conductivity meter were used with the measured instruments in hydraulic scale model. NaCl with a tracer was used to evaluate the advection phenomena under the different velocity profiles. The arrival time of the maximum concentration in the condition of the relatively fast velocity was measured about 30 seconds faster than ones in the conditions of low velocity. The measured concentrations of the tracer were shown in the detection points of the flow direction consecutively.

스마트 미터를 위한 표준 (Standards for Smart Meters)

  • 이경준;이진영;최진호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2017
  • 스마트 그리드에서 전력 정보의 수집 및 분석은 필수적이다. 수집된 전력 정보는 발전 및 배전 등 전력을 효율적으로 이용하는데 사용될 수 있다. 전력 정보 수집을 위해서는 유무선 망을 통한 스마트 미터의 통신이 중요한 역할을 한다. 현재, 세계 여러 나라들은 수많은 스마트 미터의 전력 정보 수집을 위해서 스마트 미터 통신을 위한 국제 표준 혹은 각 국가의 고유한 표준을 정립하고 있는 중이다. 따라서, 이 논문은 스마트 미터 관련 논문 및 자료들을 조사하여 스마트 미터 통신을 위한 국제 및 여러 국가별 표준에 대해 요약한다.

고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구 (A Study on the High-Accuracy Power Meter and Reliability Verification Plan)

  • 이상훈;이창화
    • 한국멀티미디어학회논문지
    • /
    • 제20권7호
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.