• Title/Summary/Keyword: Energy margin sensitivity

Search Result 25, Processing Time 0.038 seconds

Generation Rescheduling Priority using Transient Energy Margin Sensitivity (과도에너지 마진의 감도를 이용한 발전력 재배분의 Priority)

  • Kim, Kyu-Ho;Kim, Soo-Nam;Rhee, Sang-Bong;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1086-1090
    • /
    • 2011
  • This paper presents a method to evaluate generation rescheduling priority using transient energy margin sensitivity for power system operation. A change in any of the functional parameters obviously causes a change in the energy margin. Especially the energy margin sensitivity is evaluated for change with respect to generation. For a given contingency, the energy margin is computed and the respective sensitivities are also computed. It is possible to rank the sensitivities and thereby determine the generators which will affect the energy margin most and hence affect the stability (instability) of the system. The sign of the sensitivity indicates the direction of change in generation for a given change in energy margin.

Application of Newton's Approach for Transient Stability Improvement by Using Generation Rescheduling (발전력 재배분을 이용하여 과도안정도를 향상하기 위한 Newton's Approach 응용)

  • Kim, Kyu-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.68-75
    • /
    • 2013
  • This paper presents a scheme to improve transient stability using Newton's Approach for generation rescheduling. For a given contingency, the energy margin and sensitivities are computed. The bigger energy margin sensitivity of generator is, the more the generation of the generator effects to the transient stability. According to energy margin sensitivity, the control variables of generation rescheduling are selected. The fuel cost function is used as objective function to reallocate power generation. The results are compared to the results of time simulation to show its the effectiveness.

Generation Rescheduling Based on Energy Margin Sensitivity for Transient Stability Enhancement

  • Kim, Kyu-Ho;Rhee, Sang-Bong;Hwang, Kab-Ju;Song, Kyung-Bin;Lee, Kwang Y.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.20-28
    • /
    • 2016
  • This paper presents a generation rescheduling method for the enhancement of transient stability in power systems. The priority and the candidate generators for rescheduling are calculated by using the energy margin sensitivity. The generation rescheduling formulates the Lagrangian function with the fuel cost and emission such as NOx and SOx from power plants. The generation rescheduling searches for the solution that minimizes the Lagrangian function by using the Newton’s approach. While the Pareto optimum in the fuel cost and emission minimization has a drawback of finding a number of non-dominated solutions, the proposed approach can explore the non-inferior solutions of the multiobjective optimization problem more efficiently. The method proposed is applied to a 4-machine 6-bus system to demonstrate its effectiveness.

Optimal Power Flow based on Priority of Generation Rescheduling (발전력재배분의 priority를 이용한 최적전력조류)

  • Kim, Kyu-Ho;Kim, Soo-Nam;Rhee, Sang-Bong;Lee, Sang-Keun;Song, Kyung-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.412-413
    • /
    • 2011
  • This paper presents a new generation rescheduling approach for preventive control of power systems, which can optimally reallocate power generations for unstable contingencies. The transient stability constraints used in the optimal rescheduling model are described by energy margin sensitivity. Especially the energy margin sensitivity is evaluated for change with respect to generation. For a given contingency, the energy margin is computed and the respective sensitivities are also computed.

  • PDF

A Study on the RF performance analysis for Multi-band Ultra Wide Band Systems (멀티밴드 UWB 시스템의 무선성능 분석에 관한 연구)

  • Choi, Seok;Kim, Gil-Gyeom;Kwack, Jun-Ho;Kim, Hak-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12A
    • /
    • pp.951-957
    • /
    • 2003
  • The analysis of RF performance requirement conditions on communication system is critical indicator to predict the performance of system. UWB(Ultra Wide Band) system which the standard is not established yet is difficult to derive the precise system performance requirement condition. Also, there are differences between conventional UWB system and multi-band system about RF performance requirement condition. In this thesis, the differences are analyzed and performance requirement conditions of multi-band UWB system are described on the basis of the differences. Throughput, maximum transmit power, and sensitivity of multi-band UWB system is varied with respect to the number of Sub-Bands. In addition, because of Multi-path effect, if PRF(Pulse Repetition Frequency) is changed, the Multi-path link margin is happened to compensate for Multi-path Energy Loss which is contributed by increasing of the Link Margin. According to Multi-path Margin, the variation of the resistance with respect to sensitivity and interference signal is observed and analyzed through the simulation.

The Sensitivity Analysis for LRV Opening Pressure in CANDU (중수로 원전에서 액체방출밸브의 개방압력에 대한 민감도평가)

  • Kim, S.M.;Kho, D.W.;You, S.C.;Kim, J.H.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.40-44
    • /
    • 2015
  • Sensitivity on the reactor safety was evaluated for the safety margin and time delay applied to the opening pressure of liquid relief valve(LRV) of the primary heat transport system(PHTS) in the pressurized heavy water reactor(PHWR) type nuclear power plant. Since the LRV is the pressure boundary for the PHTS in the safety analysis, the operating of LRV has a significant effect on the safety analysis results. Therefore it is required during the regulatory review of Wolsong Unit 1 safety analysis to find the safety effect of the application of safety margin and time delay to the LRV opening pressure for the safety analysis of PHTS pressurizing events.

A SENSITIVITY STUDY ON NEUTRONIC PROPERTIES OF DUPIC FUEL

  • Park, Hangbok;Roh, Gyu-Hog
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.124-129
    • /
    • 1998
  • A sensitivity study has been done to determine the composition of DUPIC fuel from the viewpoint of neutronics fuel design. The spent PWR fuel compositions were generated and fissile contents adjusted by blending fresh uranium after mixing two spent PWR fuel assemblies. The $^{239}$ Pu and $^{235}$ U enrichments of DUPIC fuel were adjusted by controlling the amount of fresh uranium feed and the ratio of slightly enriched and depleted uranium in the fled uranium. Based on the material balance calculation, it is recommended that DUPIC fuel composition be such that spent PWR fuel utilization is more than 90%.. A sensitivity study on the temperature reactivity coefficient of DUPIC fuel has shown that it is desirable to increase the $^{239}$ Pu and $^{235}$ U contents to reduce both the fuel and coolant temperature coefficients. On the other hand, refueling simulations of the DUPIC core have shown that the channel power peaking factor, which is a measure of the reactor trip margin, increases with the total fissile content. Considering these neutronic characteristics of the DUPIC fuel, il is recommended to have enrichments of 0.45 and 1.00 wt% for $^{239}$ Pu and $^{235}$ U, respectively.

  • PDF

Sensitivity Analysis of Core Neutronic Parameters in Electron Accelerator-driven Subcritical Advanced Liquid Metal Reactor

  • Ebrahimkhani, Marziye;Hassanzadeh, Mostafa;Feghhi, Sayed Amier Hossian;Masti, Darush
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • Calculation of the core neutronic parameters is one of the key components in all nuclear reactors. In this research, the energy spectrum and spatial distribution of the neutron flux in a uranium target have been calculated. In addition, sensitivity of the core neutronic parameters in accelerator-driven subcritical advanced liquid metal reactors, such as electron beam energy ($E_e$) and source multiplication coefficient ($k_s$), has been investigated. A Monte Carlo code (MCNPX_2.6) has been used to calculate neutronic parameters such as effective multiplication coefficient ($k_{eff}$), net neutron multiplication (M), neutron yield ($Y_{n/e}$), energy constant gain ($G_0$), energy gain (G), importance of neutron source (${\varphi}^*$), axial and radial distributions of neutron flux, and power peaking factor ($P_{max}/P_{ave}$) in two axial and radial directions of the reactor core for four fuel loading patterns. According to the results, safety margin and accelerator current ($I_e$) have been decreased in the highest case of $k_s$, but G and ${\varphi}^*$ have increased by 88.9% and 21.6%, respectively. In addition, for LP1 loading pattern, with increasing $E_e$ from 100 MeV up to 1 GeV, $Y_{n/e}$ and G improved by 91.09% and 10.21%, and $I_e$ and $P_{acc}$ decreased by 91.05% and 10.57%, respectively. The results indicate that placement of the Np-Pu assemblies on the periphery allows for a consistent $k_{eff}$ because the Np-Pu assemblies experience less burn-up.

A Study for Evaluating of Voltage Stability Margin Considering Shunt Capacitor (조상설비를 고려한 전압안정성 여유전력의 평가에 관한 연구)

  • 김세영
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 1998
  • This paper presents a fast calculation method for evaluating of voltage stability margin (MW) using the line flow equation in polar form. Here, Line flow equations $(P_{ij},\;Q_{ij}$ are comprised of state variable, $V_i,\;{\Delta}_i,\;V_j$ and ${Delta}_j$, and line parameter, r and x. using the feature of polar coordinate, these becomes one equation with two variables, $V_j,;V_j$. Moreover, if bus j is slack or generator bus, which is specified voltage magnitude in load flow calculation, it becomes one equation with one variable $V_ i $ that is, may be formulated with the second-order equation for $V^2_i$. Therefore, multiple load flow solutions may be obtained with simple computation. The obtained load flow multiple solutions are used for evaluating of voltage stability through sensitivity analysis or its closeness. Also, the method is proposed to calculate for voltage stability margin considering shunt capacitor, which is important element for evaluating of voltage stability. The proposed method was validated to sample systems.

  • PDF

Development of Statistical Package for Uncertainty and Sensitivity Analysis(SPUSA) and Application to High Level Waste Repostitory System (불확실도와 민감도 분석용 통계 패키지(SPUSA)개발 및 고준위 방사성 폐기물 처분 계통에의 응용)

  • Kim, Tae-Woon;Cho, Won-Jin;Chang, Soon-Heung;Le, Byung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.249-265
    • /
    • 1987
  • For the probabilistic risk assessment of the high level radioactive waste repository, some methods have been proposed up to now. Since the system has highly uncertain input parameters, the evaluated risk for some input parameter values has high uncertainty. In this paper, methods of uncertainty and sensitivity analysis are devised to analyse systematically these factors and applied to a probabilistic risk assessment model of the high level waste repository, The statistical package SPUSA developed through this study can be used for any other fields, e.g., statistical thermal margin analysis, source term uncertainty analysis, etc.

  • PDF