• 제목/요약/키워드: Energy flux density

검색결과 261건 처리시간 0.026초

권선계자형 동기전동기의 d축 쇄교자속에 의한 계자전류리플 보상 기법 개발 (Development of Field Current ripple Compensating Method by d-axis Flux-linkage in WRSM)

  • 황대연;구본관
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1165-1173
    • /
    • 2018
  • Recently, owing to environmental problems and instability of rare earth resources market, non-rare earth electric motors are attracting attention. As a non-rare earth motor type, a wound rotor synchronous motor(WRSM) has high power density and wide driving range further it can reduce loss by field current control during field weakening control at high speed. However, since the d-axis flux of the WRSM is coupled with the rotor circuit, the fluctuation in the d-axis flux linkage affects the rotor circuit, which causes ripple of the field current and torque. In this paper, we propose the field current ripple compensation method by injecting the feedforward voltage. the proposed compensating method was demonstrated by simulation and experiments.

주간에 두 타워로부터 관측된 에디 공분산 자료의 확률 오차의 추정 (Estimation of the Random Error of Eddy Covariance Data from Two Towers during Daytime)

  • 임희정;이영희;조창범;김규랑;김백조
    • 대기
    • /
    • 제26권3호
    • /
    • pp.483-492
    • /
    • 2016
  • We have examined the random error of eddy covariance (EC) measurements on the basis of two-tower approach during daytime. Two EC towers were placed on the grassland with different vegetation density near Gumi-weir. We calculated the random error using three different methods. The first method (M1) is two-tower method suggested by Hollinger and Richardson (2005) where random error is based on differences between simultaneous flux measurements from two towers in very similar environmental conditions. The second one (M2) is suggested by Kessomkiat et al. (2013), which is extended procedure to estimate random error of EC data for two towers in more heterogeneous environmental conditions. They removed systematic flux difference due to the energy balance deficit and evaporative fraction difference between two sites before determining the random error of fluxes using M1 method. Here, we introduce the third method (M3) where we additionally removed systematic flux difference due to available energy difference between two sites. Compared to M1 and M2 methods, application of M3 method results in more symmetric random error distribution. The magnitude of estimated random error is smallest when using M3 method because application of M3 method results in the least systematic flux difference between two sites among three methods. An empirical formula of random error is developed as a function of flux magnitude, wind speed and measurement height for use in single tower sites near Nakdong River. This study suggests that correcting available energy difference between two sites is also required for calculating the random error of EC data from two towers at heterogeneous site where vegetation density is low.

A New Method for Coronal Force-Free Field Computation That Exactly Implements the Boundary Normal Current Density Condition

  • 이시백;전홍달;이중기;최광선
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.71.3-71.3
    • /
    • 2019
  • Previously we developed a method of coronal force-free field construction using vector potentials. In this method, the boundary normal component of the vector potential should be adjusted at every iteration step to implement the boundary normal current density, which is provided by observations. The method was a variational method in the sense that the excessive kinetic energy is removed from the system at every iteration step. The boundary condition imposing the normal current density, however, is not compatible with the variational procedure seeking for the minimum energy state, which is employed by most force-free field solvers currently being used. To resolve this problem, we have developed a totally new method of force-free field construction. Our new method uses a unique magnetic field description using two scalar functions. Our procedure is non-variational and can impose the boundary normal current density exactly. We have tested the new force-free solver for standard Low & Lou fields and Titov-Demoulin flux ropes. Our code excels others in both examples, especially in Titov-Demoulin flux ropes, for which most codes available now yield poor results. Application to a real active region will also be presented.

  • PDF

고속직류전동기의 특성 연구 (A Study on the Characteristic of a High Speed DC Motor)

  • 김현철;공영경;황영문;송종현;황재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.56-58
    • /
    • 1993
  • This report describes the high speed DC motor (8,000 rpm) that we have designed, manufactured and tested. DC motor is the best drive system in electric-mechanical energy conversion. The design concept for high speed and high energy density to DC motor is to maximize Ampere-conductor in armature and to maximize flux density in armature teeth, armature core, pole, yoke using flux path.

  • PDF

INVESTIGATING THE PULSAR WIND NEBULA 3C 58 USING EMISSION MODELS

  • Kim, Seungjong;Park, Jaegeun;An, Hongjun
    • 천문학회지
    • /
    • 제52권5호
    • /
    • pp.173-180
    • /
    • 2019
  • We present IR flux density measurements, models of the broadband SED, and results of SED modeling for the Pulsar Wind Nebula (PWN) 3C 58. We find that the Herschel flux density seems to be slightly lower than suggested by interpolation of previous measurements in nearby wavebands, implying that there may be multiple electron populations in 3C 58. We model the SED using a simple stationary one-zone and a more realistic time-evolving multi-zone scenario. The latter includes variations of flow properties in the PWN (injected energy, magnetic field, and bulk speed), radiative energy losses, adiabatic expansion, and diffusion, similar to previous PWN models. From the modeling, we find that a PWN age of 2900-5400 yrs is preferred and that there may be excess emission at ${\sim}10^{11}Hz$. The latter may imply multiple populations of electrons in the PWN.

Dual-frequency Capacitively Coupled Plasma-enhanced Chemical Vapor Deposition System for Solar Cell Manufacturing

  • 권형철;원임희;신현국;;이재구
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.310-311
    • /
    • 2011
  • Dual-frequency (DF) capacitively coupled plasmas (CCP) are used to separately control the mean ion energy and flux at the electrodes [1]. This separate control in capacitively coupled radio frequency discharges is one of the most important issues for various applications of plasma processing. For instance, in the Plasma Enhanced Chemical Vapor Deposition processes such as used for solar cell manufacturing, this separate control is most relevant. It principally allows to increase the ion flux for high deposition rates, while the mean ion energy is kept constant at low values to prevent highly energetic ion bombardment of the substrate to avoid unwanted damage of the surface structure. DF CCP can be analyzed in a fashion similar to single-frequency (SF) driven with effective parameters [2]. It means that DF CCP can be converted into SF CCP with effective parameters such as effective frequency and effective current density. In this study, comparison of DF CCP and its converted effective SF CCP is carried out through particle-in-cell/Monte Carlo (PIC-MCC) simulations. The PIC-MCC simulation shows that DF CCP and its converted effective SF CCP have almost the same plasma characteristics. In DF CCP, the negative resistance arises from the competition of the effective current and the effective frequency [2]. As the high-frequency current increases, the square of the effective frequency increases more than the effective current does. As a result, the effective voltage decreases with the effective current and it leads to an increase of the ion flux and a decrease of the mean ion energy. Because of that, the negative resistance regime can be called the preferable regime for solar cell manufacturing. In this preferable regime, comparison of DF (13.56+100 or 200 MHz) CCP and SF (60 MHz) CCP with the same effective current density is carried out. At the lower effective current density (or at the lower plasma density), the mean ion energy of SF CCP is lower than that of DF CCP. At the higher effective current density (or at the higher plasma density), however, the mean ion energy is lower than that of SF CCP. In this case, using DF CCP is better than SF CCP for solar cell manufacturing processes.

  • PDF

Estimation of the neutron production of KSTAR based on empirical scaling law of the fast ion stored energy and ion density under NBI power and machine size upgrade

  • Kwak, Jong-Gu;Hong, S.C.
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2334-2337
    • /
    • 2022
  • Deuterium-tritium reaction is the most promising one in term of the highest nuclear fusion cross-section for the reactor. So it is one of urgent issues to develop materials and components that are simultaneously resistant to high heat flux and high energy neutron flux in realization of the fusion energy. 2.45 MeV neutron production was reported in D-D reaction in KSTAR and regarded as beam-target is the dominant process. The feasibility study of KSTAR to wide area neutron source facility is done in term of D-D and D-T reactions from the empirical scaling law from the mixed fast and thermal stored energy and its projection to cases of heating power upgrade and DT reaction is done.

Effect of Sheath Structure on Operating Stability in an Anode Layer Thruster

  • Yasui, Shinsuke;Yamamoto, Naoji;Komurasaki, Kimiya;Arakawa, Yoshihiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.245-250
    • /
    • 2004
  • The discharge current oscillation has been measured for various hollow anode widths and its axial positions using a 1㎾-class anode layer hall thruster. As a result, there were thresholds of magnetic flux density for stable discharge. The plasma structure inside the hollow anode was numerically analyzed using the fully kinetic 2D3V Particle-in-Cell (PIC) and Direct Simulation Monte Carlo (DSMC) methods. The results reproduced both stable and unstable operation modes. In the stable operation case, which corresponds to the case with low magnetic flux, the plasma penetrated into the hollow anode deeper than the case with higher magnetic flux density case. This suggests that comparably large substantial anode area should contribute to stable operation.

  • PDF

균일한 열유속을 갖는 가열된 평판에 부착된 발포알루미늄에 대한 원형 충돌제트의 열유동 특성 (Heat Flow of Round Jet Impinging Aluminum Foam Mounted on the Heated Plate with Constant Heat Flux)

  • 한영희;이계복;이충구
    • 에너지공학
    • /
    • 제18권2호
    • /
    • pp.108-113
    • /
    • 2009
  • 균일한 열유속을 갖는 가열된 평판에 부착된 발포 알루미늄에 대한 충돌제트의 열유동 특성에 대한 실험적 연구가 수행되었다. 열전달 특성에 대한 기공도, 다공성 물질의 두께, Reynolds 수의 영향이 고찰되었다. 실험결과 가열평판에 부착된 발포 알루미늄에 의해 열전달의 증가를 얻을 수 있었고 다공성 물질의 삽입에 의한 열전달 증가는 열전달 표면적의 증가와 압력 손실에 의한 운동량 감소에 의해 영향을 받는 것을 확인하였다.

접지층에서 대기난류의 역할과 에너지 평형 (Role of Atmospheric Turbulences and Energy Balances in the Atmospheric Surface Layer)

  • 권병혁;김근희;김광호;강동환
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.105-113
    • /
    • 2009
  • 연안습지 생태계에서 열에너지 교환 과정은 매우 중요하다. 지표 열에너지 평형을 이루는 요소인 순복사플럭스, 현열 플럭스, 잠열 플럭스 그리고 토양열 플럭스를 전라남도 고흥에 위치한 수평적으로 균질하다고 판단되는 지역인 고흥만 간척지에서 관측하고 분석하였다. 열의 수송을 평가하기 위해서 5회의 집중관측 기간에 대기 난류를 측정하였고, 특히 갈대로 덮여있는 간척지에서 지표층 열에너지 수지를 분석하기 위해서는 물과 매우 미세한 입자로 구성된 토양 그리고 계절에 따라 색깔과 밀도가 변하는 식생캐노피를 고려하였다. 순복사 플럭스, 현열 플럭스, 잠열 플럭스, 토양열 플럭스를 기존의 에너지 수지방정식에 적용하여 식생과 토양과 같은 지표면 특성에 따른 열 플럭스의 특징을 조사하여 습지의 기온조절 효과에 대해 알아보았다. 에너지 수지비로 식생 성장기에는 주로 잠열 플럭스에 의해 열이 대기로 전달되는 것을 알 수 있었다. 또한 식생층은 열을 저장하여 기온의 일교차를 줄이는 역할을 한다. 여름철에 집중관측지의 기온이 주변 지역의 기온보다 보다 낮고 겨울철에는 다소높게 나타난 결과는 식생층을 포함하는 연안습지가 열환경을 조절함을 보여주었다.

  • PDF