• Title/Summary/Keyword: Energy flux density

Search Result 261, Processing Time 0.031 seconds

Performance Analysis of Thermosphon Using Phase Change Material (상변화 물질을 이용한 열사이폰의 성능 분석)

  • Paek, Yee;Cho, Ki-Hyon;Lee, Joo-Seong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.219-228
    • /
    • 2000
  • In order to evaluate the applicability of thermosyphon as an equipment of heat transfer to the case where natural of low temperature and low density is necessary and to propose the possibility of using natural energy being clean and inexhaustible, a thermosypon using methanol as working fluid was constructed and its transfer characteristics were analysed. The wall temperature of the thermosyphon was maintained relatively uniform after rapid increase until after being heated about ten minutes regardless of the level of input powers to the evaporating section. Inner pressure of the thermosyphon increased rapidly until after ten minutes, and then increased slowly depending on the level of input power. But heat transfer coefficient of the condensible section decreased in inverse proportion to input powers of 250~300W, showing $1008.3{\sim}829.8W/m^2{\cdot}^{\circ}C$. For the input powers of the thermosyphon within the range of 100~250W, heat transferred and heat flux increased relatively linearly showing, in the case of input powers of 250~300W, heat transfer efficiency considerable increased, showing 63.8%.

  • PDF

Study on the variation of surface characteristics of organic films as a function of bias power by O2 plasma (O2 플라즈마 바이어스 파워에 따른 유기 박막의 표면 특성 변화 연구)

  • Ham, Yong-Hyun;Baek, Kyu-Ha;Do, Lee-Mi;Sin, Hong-Sik;Park, Suk-Hyung;Kwon, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.57-57
    • /
    • 2009
  • In this work, we carried out the variation of surface characteristics of organic polymer films by O2 plasma. The plasma diagnostics were performed by DLP(Double Langmuir Probe) and OES(Optical Emission Spectroscopy) measurements. Moreover, variation of surface characteristics were measured by AFM(Atomic Force Microscope), XPS(X-ray Photoelectron Spectroscopy), and contact angle goniometer. It was found that the etch rate of organic films was controlled by O radicals flux and dc bias voltage. And O radical density and dc bias voltage increased with increasing bias power. So, it was changed surface energy as a function of surface roughness and O/C ratio in organic films.

  • PDF

Development Progress of a 300 kW-class HTS DC Induction Furnace (300 kW 급 대용량 초전도 직류 유도가열로 개발)

  • Choi, Jongho;Go, Byeong-Soo;Park, Hee-Chul;Park, Minwon;Yu, In-Keun;Kim, Seokho;Sim, Kideok;Jo, Sangho;Jo, Jinsik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1112-1113
    • /
    • 2015
  • In the end of 2014, Changwon National University and TECHSTEEL Co., Ltd. had initiated a project on the development of a 300 kW-class HTS DC Induction Furnace(HTS DC IF) for preheating non-ferrous metal billets funded by the Korea Institute of Energy Technology Evaluation and Planning for 3 years. This is the one of the most realistic commercial machines applying the coated conductors. In this paper, the development progress of a 300 kW-class HTS DC IF was introduced. The major characteristics of the furnace including its capacity, structure and operation scheme were presented. For ensuring the successful design, a pre-validation study was performed through the electromagnetic, heat transfer and solid mechanical analysis using a multi-physics FEM tool. The aluminum billet was heated up to $540^{\circ}C$ under 1 T of the magnetic flux density at the center of the billet, and the simulation results were described in detail.

  • PDF

Effect of the Temperature and Pressure on Pressure Retarded Osmosis Performance (온도와 압력 변화가 압력지연삼투 공정 성능에 미치는 영향)

  • Sim, Jin-woo;Nam, Sook-Hyun;Koo, Jae-Wuk;Kim, Eun-Ju;Yoon, Young Han;Hwang, Tae-Mun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.321-325
    • /
    • 2016
  • The Pressure Retarded Osmosis (PRO) is the next generation desalination technique and is considered as a eco-friendly energy. This was conducted to evaluate the effect of the temperature and pressure on the PRO performance. The flux of the permeation was measured under different operating conditions and estimated the power density. An improvement of PRO performance is depend on increasing solution temperature and optimum pressure. The effect of increasing feed solution temperature has stronger impact on the PRO performance comparing to the draw solution temperature. The reason of the results was due to the change of osmotic power, viscosity, water permeability and structure parameter(s).

A STUDY OF LYNDS 1251 DARK CLOUD: II. INFRARED PROPERTIES

  • LEE YOUNGUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.107-117
    • /
    • 1996
  • We have studied the star forming activities and dust properties of Lynds 1251, a dark cloud located at relatively high galactic latitude. Eleven IRAS point sources identified toward Lynds 1251 are discussed. Estimate of stellar masses, and far-infrared lumnosities of the young stars associated with two prominent IRAS point sources imply that these are T-Tauri stars with masses smaller than $0.3 M_\bigodot$. The low dust temperature of 27 K and low ratio of FIR emission to hydrogen column density are probably due to the lack of internal heating sources. Presumably two low mass young stars do not have enough energy to heat up the dust and gas associated. The dust heating is dominated by the interstellar heating source, and the weaker interstellar radiation field can explain the exceptionally low dust temperatures found in Lynds 1251. The estimated dust mass of Lynds 1251 is just $\~1M_\bigodot$, or about 1/1000 of gas mass, which implies that there must be a substantial amount of colder dust. The infrared flux at $100{\mu}m$ is matching well with $^{13}CO$ peak temperature, while the $^{12}CO$ integrated intensity is matching with the boundary of dust emission. Overall, the dust properties of Lynds 1251 is similar to those of normal dark clouds even though it does have star forming activities.

  • PDF

Removal characteristics of organic matter during pretreatment for membrane-based food processing wastewater reclamation

  • Jang, Haenam;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.205-210
    • /
    • 2018
  • In this study, we investigated coagulants such as polyaluminum chloride (PACl) and ferric chloride ($FeCl_3$) and the combination of a coagulant and powdered activated carbon (PAC) for the removal of dissolved organic matter (DOM) from fish processing effluent to reduce membrane fouling in microfiltration. The efficiency of each pretreatment was investigated through analyses of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$). Membrane flux and silt density index (SDI) analyses were performed to evaluate membrane fouling; molecular weight distributions (MWD) and fluorescence excitation-emission matrix (FEEM) spectroscopy were analyzed to assess DOM characteristics. The results demonstrated that $FeCl_3$ exhibited higher DOC and $UVA_{254}$ removals than PACl for food processing effluent and a combination of $FeCl_3$ and PAC provided comparatively better results than simple $FeCl_3$ coagulation for the removal of DOM from fish processing effluent. This study suggests that membrane fouling could be minimized by proper pretreatment of food processing effluent using a combination of coagulation ($FeCl_3$) and adsorption (PAC). Analyses of MWD and FEEM revealed that the combination of $FeCl_3$ and PAC was more efficient at removing hydrophobic and small-sized DOM.

Rheological and Magnetic Properties of Plastic Ferrite Magnets (플라스틱 페라이트 자석의 레올로지와 자기특성)

  • 이석희;최준환;문탁진;정원용
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.3
    • /
    • pp.150-155
    • /
    • 1998
  • The purpose of this study is to investigate the variations of rheological and magnetic properties with powder loading in plastic anisotropic ferrite magnets. The measured relative viscosities with powder loading were compared with the calculated ones. The variation of relative viscosities with powder loading was in good agreement with that of particle alignment. Remanent flux density and maximum energy product increased linearly with the increase of powder loading, and then showed maximum values. The decrease of magnetic properties at high powder loading was caused by rapid decrease of particle alignment due to the drastic increase of mixture viscosity. The powder loading for maximum magnetic properties is dependent on magnetic field during injection molding and melt viscosity of binder, so the binder with low melt viscosity is necessary to fabricate the magnet with high properties.

  • PDF

Exhaust Plasma Characteristics of Direct-Current Arcjet Thrusters

  • Tahara, Hirokazu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.327-334
    • /
    • 2004
  • Spectroscopic and electrostatic probe measurements were made to examine plasma characteristics with or without a metal plate for a 10-㎾-class direct-current arcjet Heat fluxes into the plate from the plasma were also evaluated with a Nickel slug and thermocouple arrangement. Ammonia and mixtures of nitrogen and hydrogen were used. The NH$_3$ and $N_2$+3H$_2$ plasmas in the nozzle and in the downstream plume without a plate were in thermodynamical nonequilibrium states. As a result, the H-atom electronic excitation temperature and the $N_2$ molecule-rotational excitation temperature intensively decreased downstream in the nozzle although the NH molecule-rotational excitation temperature did not show an axial decrease. Each temperature was kept in a small range in the plume without a plate except for the NH rotational temperature for NH$_3$ gas. On the other hand, as approaching the plate, the thermodynamical nonequilibrium plasma came to be a temperature-equilibrium one because the plasma flow tended to stagnate in front of the plate. The electron temperature had a small radial variation near the plate. Both the electron number density and the heat flux decreased radially outward, and an increase in H$_2$ mole fraction raised them at a constant radial position. In cases with NH$_3$ and $N_2$+3H$_2$ a large number of NH radical with a radially wide distribution was considered to cause a large amount of energy loss, i.e., frozen flow loss, for arcjet thrusters.

  • PDF

An Experimental Study on the Characteristics of the High Temperature Superconductor as an Application of the Repulsive Type Magnetic Bearing (반발식 자기 베어링의 응용으로서 고온 초전도체의 특성에 관한 실험적 연구)

  • 유제환;임윤철
    • Tribology and Lubricants
    • /
    • v.13 no.2
    • /
    • pp.52-59
    • /
    • 1997
  • An experimental study is presented for the characteristics of the high temperature superconductor as an application of the repulsive type magnetic bearing. A ring shaped YBCO type superconductor and Neodium permanent magnets are employed for the experiment. For the case of field cooling, superconductor shows strong repulsive force, which is due to the Meissner effect, as the gap between the superconductor and the magnet gets closer. The repulsive force variation with respect to the gap change shows hysterisis characteristics. The area of the loop of the hysterisis curve represents the dissipation of energy, which reveals that the magnetic bearing with superconductor has large damping. The effect of the initial gap and the magnetic flux density on the repulsive force is analyzed experimentally and the static stiffness variation is calculated from the measured repulsive force variation. The relative sliding velocity between the superconductor and the magnet has little effect on the repulsive force which is quite different from the usual sliding element bearing. As the initial gap for the field cooling becomes larger, the maximum repulsive force at the minimum gap increases and approaches to the value for the case of zero field cooling.

Critical Characteristics Estimation of a Large-Scale HTS Wind Turbine Generator Using a Performance Evaluation System

  • Kim, Taewon;Woo, Sang-Kyun;Kim, Changhyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.229-233
    • /
    • 2019
  • Large-scale High Temperature Superconducting (HTS) wind power generators suffer from high electromagnetic force and high torque due to their high current density and low rotational speed. Therefore, the torque and Lorentz force of HTS wind power generators should be carefully investigated. In this paper, we proposed a Performance Evaluation System (PES) to physically test the structural stability of HTS coils with high torque before fabricating the generator. The PES is composed of the part of a pole-pair of the HTS generator for estimating the characteristic of the HTS coil. The 10 MW HTS generator and PES were analyzed using a 3D finite element method software. The performance of the HTS coil was evaluated by comparing the magnetic field distributions, the output power, and torque values of the 10 MW HTS generator and the PES. The magnetic flux densities, output power, and torque values of the HTS coils in the PES were the same as a pole-pair of the 10 MW HTS generator. Therefore, the PES-based evaluation method proposed in this paper can be used to estimate the critical characteristics of the HTS generator under high magnetic field and high torque before manufacturing the HTS wind turbines. These results will be used effectively to research and manufacture large-scale HTS wind turbine generators.