• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 872, Processing Time 0.029 seconds

An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House (단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가)

  • Baek, Namchoon;Han, Seunghyun;Lee, Wang Je;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.

A Study on Sequential-Frequency Sonication for Improving Anaerobic Digestion (혐기성 소화 효율 향상을 위한 초음파 주파수의 순차적 적용에 대한 연구)

  • Whang, Gye-Dae;Park, Sung-Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.893-906
    • /
    • 2011
  • The effect of ultrasound pretreatment on sludge degragability was investigated at different condotions: ultrasonic frequency(28, 40, 50kHz), intensity(10, 25, 50W), sonication time(10, 20, 30, 60min). Total suspended solid(TSS) and soluble chemical oxygen demand(SCOD) concentration were measured for the evaluation of pretreatment efficiency. The pretreated sludge was used as the feedstock for anaerobic digestion process. Biogas production and volatile suspended solid(VSS) removal were determined for evaluating the process performance. 1. TSS concentration of the sludge decreased at a constant rate as sonication operation was applied. The degradation rate of TSS increased when ultrasound frequency was decreased from 50kHz to 28kHz and intensity was increased from 10W to 50W. Efficiency of TSS degradation per input energy increased as ultrasonic frequency and intensity were decreased. At the frequency of 28 and 40kHz, SCOD concentration rapidly increased during the initial 30min of sonication time, and then it gradually increased. At 50kHz, SCOD concentration constantly increased for 60min of the sonication time. The SCOD production rate increased with increasing intensity under all ultrasound frequencies. 2. The optimum condition of ultrasound treatment was 28kHz, 50W and 60min for maximizing the biogas production, methane fraction, VSS removal. The highest values in biogas production, methane fraction in biogas, VSS removal were 370ml, 70%, 2.45g, respectively. Methane production rate per input energy increased at ultrasonic frequency and intensity decreased. 3. When raw sludge was pretreated at the condition of ultrasonic frequency of 28 and 40kHz in series, sequential-frequency sonication, intensity of 50W and 60min, biogas production, methane fraction, VSS removal were about the same that of 28kHz single-frequency sonication. When sequential-frequency sonication of 28 and 50kHz was applied in series, biogas production, methane fraction, VSS removal were 356 ~ 423ml, 69 ~ 71%, 2.41 ~ 2.78g, respectively. The pretreatment efficiency of 28-50kHz sequential-frequency sonication which sonication time of 28kHz and 50kHz was 40min and 20min was higher than that of 28kHz single-frequency sonication.

Authentication and Key Management Techniques for Secure Communication in IP Camera (IoT 환경에서 IP카메라의 효율적 운용을 위한 키 관리 및 보안 설계 프로토콜)

  • Min, So-Yeon;Lee, Jae-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.602-608
    • /
    • 2020
  • Development of Internet technology and the spread of various smart devices provide a convenient computing environment for people, which is becoming common thanks to the Internet of Things (IoT). However, attacks by hackers have caused various problems, such as leaking personal information or violating privacy. In the IoT environment, various smart devices are connected, and network attacks that are used in the PC environment are occurring frequently in the IoT. In fact, security incidents such as conducting DDoS attacks by hacking IP cameras, leaking personal information, and monitoring unspecified numbers of personal files without consent are occurring. Although attacks in the existing Internet environment are PC-oriented, we can now confirm that smart devices such as IP cameras and tablets can be targets of network attacks. Through performance evaluation, the proposed protocol shows 11% more energy efficiency on servers than RSA, eight times greater energy efficiency on clients than Kerberos, and increased efficiency as the number of devices increases. In addition, it is possible to respond to a variety of security threats that might occur against the network. It is expected that efficient operations will be possible if the proposed protocol is applied to the IoT environment.

Re-evaluation of the optimum dietary protein level for maximum growth of juvenile barred knifejaw Oplegnathus fasciatus reared in cages

  • Kim, Kang-Woong;Moniruzzaman, Mohammad;Kim, Kyoung-Duck;Han, Hyon Sob;Yun, Hyeonho;Lee, Seunghan;Bai, Sungchul C.
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.5
    • /
    • pp.24.1-24.6
    • /
    • 2016
  • We determined the optimum dietary protein level in juvenile barred knifejaw Oplegnathus fasciatus in cages. Five semi-purified isocaloric diets were formulated with white fish meal and casein-based diets to contain 35, 40, 45, 50, and 60 % crude protein (CP). Fish with an initial body weight of $7.1{\pm}0.06g$ ($mean{\pm}SD$) were randomly distributed into 15 net cages (each size: $60cm{\times}40cm{\times}90cm$, $W{\times}L{\times}H$) as groups of 20 fish in triplicates. The fish were fed at apparent satiation level twice a day. After 8 weeks of feeding, the weight gain (WG) of fish fed 45, 50, and 60 % CP diets were significantly higher than those of fish fed 35 and 40 % CP diets. However, there were no significant differences in WG among fish fed 45, 50, and 60 % CP diets. Generally, feed efficiency (FE) and specific growth rate (SGR) showed a similar trend as WG. However, the protein efficiency ratio (PER) was inversely related to dietary protein levels. Energy retention efficiency increased with the increase of dietary protein levels by protein sparing from non-protein energy sources. Blood hematocrit content was not affected by dietary protein levels. However, a significantly lower amount of hemoglobin was found in fish fed 35 % CP than in fish fed 40, 45, 50, and 60 % CP diets. Fish fed 60 % CP showed the lowest survival rate than the fish fed 35, 40, 45, and 50 % CP diets. Broken-line analysis of WG showed the optimum dietary protein level was 45.2 % with 18.8 kJ/g diet for juvenile barred knifejaw. This study has potential implication for the successful cage culture of barred knifejaw.

Comparative evaluation of supplemental zilpaterol hydrochloride sources on growth performance, dietary energetics and carcass characteristics of finishing lambs

  • Rivera-Villegas, A.;Estrada-Angulo, A.;Castro-Perez, B.I.;Urias-Estrada, J.D.;Rios-Rincon, F.G.;Rodriguez-Cordero, D.;Barreras, A.;Plascencia, A.;Gonzalez-Vizcarra, V.M.;Sosa-Gordillo, J.F.;Zinn, R.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.2
    • /
    • pp.209-216
    • /
    • 2019
  • Objective: We compare the effects of three different approved sources of supplemental zilpaterol on growth-performance responses and carcass characteristics of finishing lambs. Methods: Twenty four Pelibuey${\times}$Katahdin lambs ($46.75{\pm}2.43kg$) were used in a 33-day feeding trial. Lambs were fed a dry rolled corn-based finishing diet. Treatments consisted of the non-supplemental basal diet (Control) versus the basal diet supplemented with 125 mg zilpaterol/kg of diet (as fed basis) from three commercial sources marketed in Mexico: Zilmax (ZIL), Grofactor, and Zipamix. Results: Compared to controls, zilpaterol (ZH) supplementation did not affect dry matter intake (DMI), but increased carcass adjusted daily weight gain (ADG, 36.7%), gain efficiency (34.2%), and dietary net energy (26.0%), and decreased (23.4%) the ratio of observed:expected DMI. Compared to controls, supplemental ZH increased hot carcass weight (6.4%), dressing percentage (3.2%), m. longissimus thoracis (LM) area (15.6%), and shoulder muscle:fat ratio (28.7%), but decreased kidney-pelvic-heart fat, and fat thickness. Supplemental ZH increased 10.9% and 14.3% whole cut weight of loin and leg, respectively, and the proportion (as percentage of cold carcass weight) of leg (4.3%). These increases were reflected in greater forequarter and hindquarter weights. Lambs fed ZH increased (4.6%) empty body weight (EBW) and reduced (14.7%) liver/spleen weight (as g/kg EBW). Likewise, ZH supplementation tended (p = 0.08) to lower (8.9%) visceral fat. Growth performance, energetic efficiency, hot carcass weight, dressing percentage, LM area and whole cuts were not different across supplemental ZH sources. However, compared with non-supplemented controls, only ZIL appreciably decreased carcass fat distribution, including fat thickness, percentage kidney pelvic and heart fat, shoulder fat, and visceral fat. Conclusion: Supplemental ZH increases ADG, gain efficiency, carcass dressing percentage, and LM area. The magnitude of these responses was similar among ZH sources. Nevertheless, compared with non-supplemented controls, only ZIL appreciably decreases carcass fat. The basis for this is uncertain, but indicative that some practical differences in zilpaterol bio-equivalency may exist across commercial sources tested.

A Study on Connection of Fuel Processor and NG blower for Small Commercial Fuel Cell System (건물용 연료전지 시스템용 연료처리장치와 연료승압 블로워 연계 특성에 관한 연구)

  • Kim, Jaedong;Jang, Sejin;Kim, Bonggyu;Kim, Jinwook;Han, Sienho;Park, Dalryung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.36-44
    • /
    • 2017
  • The small commercial fuel cell is a new energy system that produces electricity and heat through electrochemical reaction between air and hydrogen. In Korea, hundreds of domestic small commercial fuel cell systems have been installed and operated every years and many parts in fuel cell systems depend on overseas products. KOGAS(Korea Gas Corporation) has developed the fuel processor which is an important part of fuel cell system and has evaluated the long-term durability. And KOGAS has evaluated domestic and overseas NG blower and fuel processor connected to NG blower. The fuel processor developed by KOGAS have maintained an efficiency of 76% and constant performance over 3,000 hours. The NG blower developed in Korea showed similar characteristics as overseas NG blower in the evaluation of power consumption according to rear pressure and outside temperature. The fuel processor module, fuel processor connected to BOP showed excellent performance.

Development and Performance Evaluation of a Filtration Equipment to Reuse PFC Waste Solution Generated on PFC Decontamination (PFC 제염 시 발생된 PFC 폐액의 재사용을 위한 여과장치 개발 및 성능평가)

  • Kim Gye-Nam;Jeong Cheol-Jin;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.161-170
    • /
    • 2006
  • PFC(Perfluorocarbon) decontamination process is one of best methods to remove hot particulate adhered on the inner surface of hot cell and surface of equipment in hot cell. It was necessary to develop a filtration equipment to reuse the PFC waste solution generated on PFC decontamination due to the high cost of PFC solution and for minimization of the volume of second waste solution. The filtration equipment was developed to remove hot particulate in PFC waste solution. It was made suitable size and weight in consideration of hot cell gate and crane. And it has wheels for easy movement. Flux of the filtration equipment decreased with particulate concentration increase. It consists of pre-filter($1.4{\mu}m$) and final-filter($0.2{\mu}m$) for protection of the flux decrease along filtration time. It treatment capacity of waste solution is 0.2 L/min.

  • PDF

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter (동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구)

  • Ryu, Ri;Seo, Jang-hoo;Kim, Yong-seong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness (에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Lee, Kee-Sun;Kim, Kil-Hee;Jung, Hee-Chang;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.45-54
    • /
    • 2015
  • This study carried out an experiment to identify subject's work effectiveness and energy saving effect using LED light. Towards this end, this study configured nine various lighting environments in order to control PWM (Pulse Width Modulation) and illuminance (lux), which are the characteristics of LED light. The PWM ratio of LED light was set as R:G:B=1:1:1, R:G:B=4:1:5, and R:G:B=8:7:7, respectively, and illuminance (lux) was set as 400 lx, 700 lx, and 1000 lx, respectively. In addition, the indoor environment was set temperature $20-24^{\circ}C$, humidity 50%-60%, and the amount of clothing 1. This study analyzed work effectiveness and energy consumption in nine lighting environments, each. Error correction was performed for work effectiveness analysis, and cumulative power consumption was measured in each lighting environment for energy consumption analysis. According to experiment results through the lighting environments suggested in this study, accuracy and spent time effectiveness were good in 700lux and higher than 400lux. For spent time, the best effectiveness was revealed in the suggested PWM ratio, R:G:B=8:7:7. The lowest power consumption on each illuminance (lux) was revealed in the order of R:G:B=8:7:7, RGB=1:1:1, and R:G:B=4:1:5. Therefore, pulse-width modulation effect is proposed in this paper was found to affect the efficiency and energy saving.

Design and performance evaluation of fish-luring system using the air-cooled LED lamp for jigging and angling boat (채낚기 어선용 공랭식 LED 집어시스템의 설계 및 성능평가)

  • Bae, Bong-Seong;Park, Byoung-Jae;Jeong, Eui-Cheol;Yang, Yong-Su;Park, Hae-Hoon;Chun, Young-Yull;Chang, Dae-Soo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.2
    • /
    • pp.85-95
    • /
    • 2009
  • The fishing lamp is a fishing gear that gathers fish at night. But the cost of oil, which is used to light fishing lamp, has been risen significantly up to 30-40% of total fishing costs. Therefore it is very urgent to develop an energy economical fishing lamp in order to solve the business difficulties of fisheries. Under this background, this research aims at developing a fishing lamp for squid jigging and hairtail angling fishery using the LED, which has excellent energy efficiency and durability. The LED fishing lamp developed can be controlled to fix a fit direction of fish shoal deep because a fishing lamp can be adjustable up and down directions. One unit of fishing lamp has about an 80Watt capacity and the frame of fishing lamp is made of aluminium to emit generated heat of LED to outside. The LED lamp developed was highly durable, only 5.7% of emitting efficiency decreased for 18 months. The illuminance of a unit LED lamp was 2,070lux at 1m and 21lux at 10 m distance, and the intensity of LED lamp system emitted 2,580lux and 400lux at the respective distances. After development of this fishing lamp, 100 units are installed on operating fishing vessels. Experimental results show that energy consumption of squid jigging and hairtail angling was reduced by 40% and 87%, respectively. In conclusion, our methods showed elevated fishing power, compared with traditional fishing method: 37.7% for squid jigging and 24.5% for hairtail angling.