• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 867, Processing Time 0.028 seconds

Evaluation of Anaerobic Fermentation and Nitrate Removal Efficiency of Sewage Sludge Pre-treated with Electrolysis (전기분해 전처리 슬러지의 혐기성 소화 및 질산염 제거효율 평가)

  • Kim, Jaehyung;Jeon, Hyeyeon;Pak, Daewonk
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • This study was performed with electrolysis treatment method for improving anaerobic digestion gas production efficiency in a sewage sludge, thereby confirmed in anaerobic digestion production and denitrification effect. As a result, solubilization was increased by increasing treatment time of electrolysis and current density, also showed to be 9.02% with 10 mA/cm2 of current density in 4 mm electrode distance. Based on the results of BMP test used the above experiment, methane production was 0.49 L CH4/g VS, and increased by 88.4% compared with control groups. As for the results of denitrification using the sewage sludge treated with the same conditions, denitrification rate appeared $19.2mg\;NO_3{^{-}}N/g\;MLVSS{\cdot}hr$, and through the sewage sludge treated with electrolysis, it can be applied to anaerobic digestion and denitrification process by increasing biodegradation.

Development and Experimental Evaluation of the Wireless Illumination Controller with Demand Response for the Smart Grid (스마트 그리드를 위한 무선 기반의 수요 반응 기능을 가지는 조명 제어용 장치 개발 및 실험적 평가)

  • Choi, In-Ho;Lee, Joung-Han;Hong, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1215-1224
    • /
    • 2011
  • Recently, a lot of research for the smart grid technology have been carried out to achieve energy efficiency for the electronic products. In order to practically apply this study, smart instruments which are capable of the AMI (Advanced Metering Infrastructure) and DR (Demand Response) function are necessary. However, it is difficult to apply the function of the smart grid to the electronic product that cannot support the smart grid. Accordingly, the efficient use of electric energy is impossible. In order to solve this problem, the electronic product has to be changed into the exclusive electronic product supporting smart grid technology or the smart controller has to be attached the outside of the device. In this study, we developed the smart controller for connecting the electric appliances to the smart grid system. It can be attached to the illumination and the smart grid-based lamp control system at home. We additionally designed the message frame and the protocol to operate the smart controller with the AMI based EMS (Energy Management Server). We developed an experimental system to practically verify functions of the smart controller which is attached to the lighting device. From the system, we showed that the electric source of the illumination can be controlled according to the load change and saved energy effectively. We also confirmed the structural benefit and the energy-efficient effect through the verification of the smart controller.

The Performance Evaluation of Plate Type STR Reactor with Variation of S/C Ratio and Fuel Supply (연료 공급 및 S/C비에 따른 평판형 STR 반응기 성능 평가)

  • Kim, Hun-Ju;Heo, Su-Bin;Park, Jae-Min;Yoon, Bong-Seok;Lee, Do-Hyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.191-198
    • /
    • 2011
  • According to the propagation of fuel cell system, the importance of that system efficiency is being magnified. Thus, the efficiency improvement of reformer which is the important factor of fuel cell system will be required. This study has been experimentally performed to evaluated the performance of plate type STR reactor. At first, we changed fuel flow rate (2, 3 and 4 l/min) in burner, and then we measured a proportion of hydrogen in produced gas through the STR reactor by G.C for evaluating the performance of plate type STR reactor in various fuel supply conditions. And we changed S/C ratio (2 and 4) and measured a proportion of hydrogen in produced gas through the STR reactor. As a results, condition at fuel flow rate 2 and 3 l/min could not be supplied amount of heat for STR sufficiently. Condition at fuel flow rate 4 l/min could supplied a heat excessively. And condition at S/C ratio 2, reaction occurred insufficiency. But condition at S/C ratio 4 was excess. From above, we found the optimum conditions that were fuel rate 3.5 l/min and S/C ratio 3.

An Energy-Efficient MAC Protocol for Werable Device WBAN Environment through Asymmetric Method and QoS (Wearable 장치를 사용하는 WBAN 환경에서 장치 간 비대칭적 에너지 효율과 QoS를 위한 MAC 제안)

  • Lee, Jae-Ho;Eom, Doo-Seop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6A
    • /
    • pp.395-404
    • /
    • 2012
  • In general, WBAN environment which use wearable devices on the human body show the different characteristics from other personal area networks. It is usually composed of sensors contacting the body and user terminal collecting the data from the sensors. The sensors are under the significant constraint of the energy resources, but the user terminal is different because it can be recharged and relatively have large energy resources. Under this characteristics, we design a new MAC protocol considering this requirements. The proposed MAC protocol can increase the energy efficiency of sensors and loads the unavoidable energy consumption to the user terminal for high energy efficiency of sensors. Additionally, the proposed MAC protocol provides the low delivery delay of the emergency information for the differentiated QoS because the emergency data requires more rapid transmission than the periodic sensed data. For this requirement, we employ the IFS (Inter Frame Space). For the efficient and objective evaluation of the proposed MAC protocol, IEEE 802.15.6 MAC is used to compare with it and we show that the advantage of the proposed MAC meet our expectation.

Development of a Pool Cleaning Robot and its Cleaning Performance Evaluation (수영장 청소 로봇 개발 및 청소성능지표)

  • Kim, Jinhyuk;Kim, Jinhyun
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.243-251
    • /
    • 2012
  • In this paper, developing of a pool cleaning robot is addressed. First, we analyze commercial pool cleaning robot mechanisms, and the merits and demerits of wireless version of a pool cleaning robot is introduced. And then the water-jet moving mechanism for a pool cleaning robot is proposed to improve energy efficiency and mechanical design advantage, which is one of the strong candidates for wireless pool cleaning robots. Next, the method of cleaning performance evaluation of pool cleaning robots is firstly defined with five key factors, and it was verified by experimental results. If the cleaning performance can be quantitatively defined, we can design optimally a pool cleaning robot, which results in the cost down.

Soundness Evaluation of 120W LED Lighting using Passive Infrared Thermal Imaging Method (수동적 적외선 열화상 기법을 적용한 120W급 LED조명등 건전성 평가)

  • Jung, Yoon-Soo;Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.140-146
    • /
    • 2017
  • As energy conservation and environmental issues are emerging as a hot topic around the world, consumers are demanding high-efficiency, eco-friendly products. In this study, the author proposed 120W LED lighting system that replace metal halide lamp (MHL) which is currently used in the industry. Furthermore, it would be possible to provide a perfect opportunity for Korea to rise as a global leader in the LED lighting industry through soundness evaluation of the LED lighting system that is applied.

Analysis on Wave Absorbing Performance of a Pile Breakwater (파일 방파제의 소파성능 해석)

  • Cho, Il-Hyoung;Koh, Hyeok-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Based on the eigenfunction expansion method, the wave-absorbing performance of a square or circular pile breakwater was investigated. Flow separation resulting from sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of an exact energy loss coefficient is critical to enhancing the reliability of the mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code, and the energy loss coefficient can be obtained from the pressure difference between upstream and downstream. It was found that energy loss coefficient of circular pile is 20% that of a square pile. To validate the fitting equation for the energy loss coefficient, comparison between the analytical results and the experimental results (Kakuno and Liu, 1993) was made for square and circular piles with good agreement. The array of square piles also provides better wave-absorbing efficiency than the circular piles, and the optimal porosity value is near P=0.1.

The Performance Evaluation Study of PV-Solarwall Unit Module Solar Thermal-Electric Energy (태양에너지를 이용한 열-전기 동시생산을 위한 PV-Solarwall 단위모듈 성능평가 연구)

  • Kim, Yong-Hwan;Cho, Yil-Sik;Lee, Euy-Joon;Hyun, Myung-Taek;Kang, Eun-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.69-75
    • /
    • 2005
  • The PV-Solarwall system has been introduced as a promising alternative to harness solar energy for both heating applications and electricity generation simultaneously. The system comprises a PV solar panel(for electricity generation). In addition, the solarwall incorporates a fan strategically located behind the PV panel to bring the warm and fresh air from the solarwall into the room. Because of its location and convective cooling principle, the fan also serves to reduce the operating temperature of the PV panel thereby increasing its efficiency. So this PV-Solarwall system holds much promise for saving heating and electricity costs compared with a PV system without solarwall. In particular, by controlling the tilt angle of the entire PV-Solarwall system between $0^{\circ}$(horizontal) and $90^{\circ}$(vertical), the performance of the system can be further evaluated. It is expected that the range of tilt angle PV-Solarwall between $40^{\circ}$ and $50^{\circ}$ will improve the output of the system.

An Evaluation for Predicting the Far Wake of Tidal Turbines

  • Yang, C.J.;Hoang, A.D.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.155-156
    • /
    • 2012
  • In the modern age, as man's demand of energy is continuously grew, tidal becomes one of the sustainable energy sources that have been investigating thoroughly recently. Tidal turbine has proved high potential as a future power-generating device. To effectively capture tidal energy on site, a group of tidal turbines should be used and positioned in some formation with proper size and space so that energy can be absorbed from multiple point. Thus, the turbines together with the flow filed becomes a huge domain, a tidal farm. So, it becomes more convenient if a whole turbine farm is simulated by means of actuator discs since the time and cost for analysis can be reduced. This paper aims to evaluate the operating performance (power efficiency and energy restoration rate), mutual influence (for different longitudinal and lateral spaces), the influence of velocity profiles, turbulence intensity and the far wake characteristic of tidal turbines operating in farm formation. The results of this study help contributing to the present development of tidal turbine as the future potential energy conversion machinery.

  • PDF

Feasibility Study on Retrofitting Lighting and Heat Source Equipments in Office Buildings (사무소건물 조명기기와 열원기기의 고효율기기로의 교체에 관한 경제성 검토)

  • Lee, Chul-goo;Kim, Jong-dae;Im, Tae-soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.2
    • /
    • pp.13-18
    • /
    • 2016
  • Energy saving has been main concern, thus government supporting policies which are based on Fundamentals of Low-carbon Green Growth Act', 'Green Building Support Act, have been prepared in Korea. The objective of this study is to estimate energy conservation effectiveness and economic advantage assuming that lighting equipments and heat source equipments would be retrofitted. Office building, which has total floor area of $30,000m^2$, was a subject of this study. From the estimations, electric rate will be decreased by 62,886,000 won per year due to lighting equipments retrofit, and gas rate will be decreased 11,141,000 won or 17,332,000 won per year due to heat source equipments retrofit (in case of COP 1.2 or 1.5). Payback period of each case that are calculated by energy saving cost and retrofit cost are estimated 27.9 year, 38.6 year and 29.2 year, thus economic supporting policies is necessary for effective energy saving in buildings. Meanwhile payback period of heat source equipment for new building is estimated 6.1 year and 8.3 year.