• Title/Summary/Keyword: Energy delivery rate

Search Result 95, Processing Time 0.024 seconds

Development of High Intensity Focused Ultrasound (HIFU) Mediated AuNP-liposomal Nanomedicine and Evaluation with PET Imaging

  • Ji Yoon Kim;Un Chul Shin;Ji Yong Park;Ran Ji Yoo;Soeku Bae;Tae Hyeon Choi;Kyuwan Kim;Young Chan Ann;Jin Sil Kim;Yu Jin Shin;Hokyu Lee;Yong Jin Lee;Kyo Chul Lee;Suhng Wook Kim;Yun-Sang Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • Liposomes as drug delivery system have proved useful carrier for various disease, including cancer. In addition, perfluorocarbon cored microbubbles are utilized in conjunction with high-intensity focused-ultrasound (HIFU) to enable simultaneous diagnosis and treatment. However, microbubbles generally exhibit lower drug loading efficiency, so the need for the development of a novel liposome-based drug delivery material that can efficiently load and deliver drugs to targeted areas via HIFU. This study aims to develop a liposome-based drug delivery material by introducing a substance that can burst liposomes using ultrasound energy and confirm the ability to target tumors using PET imaging. Liposomes (Lipo-DOX, Lipo-DOX-Au, Lipo-DOX-Au-RGD) were synthesized with gold nanoparticles using an avidin-biotin bond, and doxorubicin was mounted inside by pH gradient method. The size distribution was measured by DLS, and encapsulation efficiency of doxorubicin was analyzed by UV-vis spectrometer. The target specificity and cytotoxicity of liposomes were assessed in vitro by glioblastoma U87mg cells to HIFU treatment and analyzed using CCK-8 assay, and fluorescence microscopy at 6-hour intervals for up to 24 hours. For the in vivo study, U87mg model mouse were injected intravenously with 1.48 MBq of 64Cu-labeled Lipo-DOX-Au and Lipo-DOX-Au-RGD, and PET images were taken at 0, 2, 4, 8, and 24 hours. As a result, the size of liposomes was 108.3 ± 5.0 nm at Lipo-DOX-Au and 94.1 ± 12.2 nm at Lipo-DOX-Au-RGD, and it was observed that doxorubicin was mounted inside the liposome up to 52%. After 6 hours of HIFU treatment, the viability of U87mg cells treated with Lipo-DOX-Au decreased by around 20% compared to Lipo-DOX, and Lipo-DOX-Au-RGD had a higher uptake rate than Lipo-DOX. In vivo study using PET images, it was confirmed that 64Cu-Lipo-DOX-Au-RGD was taken up into the tumor immediately after injection and maintained for up to 4 hours. In this study, drugs released from liposomes-gold nanoparticles via ultrasound and RGD targeting were confirmed by non-invasive imaging. In cell-level experiments, HIFU treatment of gold nanoparticle-coupled liposomes significantly decreased tumor survival, while RGD-liposomes exhibited high tumor targeting and rapid release in vivo imaging. It is expected that the combination of these models with ultrasound is served as an effective drug delivery material with therapeutic outcomes.

Preparation and Characterization of L-Arginine Containing Poloxamer Hydrogels for Solubilization and Sustained Release of Amphotericin B (Amphotericin B의 가용화 및 방출지속화를 위한 아르기닌 함유 폴록사머 하이드로젤의 제조 및 특성분석)

  • Shin, Baek-Ki;Baek, Eun-Jung;Kim, Ye-Tae;Jeong, Ji-Woong;Nho, Young-Chang;Lim, Youn-Mook;Park, Jong-Seok;Huh, Kang-Moo;Park, Jeong-Sook
    • Polymer(Korea)
    • /
    • v.34 no.5
    • /
    • pp.459-463
    • /
    • 2010
  • Amphotericin B (AmB) is anti-fungal agent for the treatment of systemic fungal infections, but its poor solubility has limited clinical applications. In this study, a new gel formulation made up of L-arginine as solubilizer, thermosensitive Poloxamer 407 (P 407), and adhesive carbopol was designed for effective solubilization and delivery of AmB. The aqueous solubility of AmB was enhanced up to 2.6 mg/mL by addition of L-arginine. Aqueous P 407 solutions of more than 20% w/v showed thermo-induced sol-gel-sol phase transition. The phase transition behavior was affected by the presence of AmB and L-arginine, and the phase transition range was broadened by addition of carbopol. In vitro drug release was improved by the solubilizing effect of L-arginine, and the presence of mucoadhesive carbopol prolonged the release rate as a function of concentration.

Nutrition Status of the Rural Elderly Living in Kyungnam-Focusing on Health-Related Habits , Dietary Behaviors of Nutrient Intakes- (경남 일부 지역 노임의 영양실태조사-생활습관, 식행동 및 영양소 섭취 실태를 중심으로-)

  • 박미경;이경혜;윤현숙
    • Korean Journal of Community Nutrition
    • /
    • v.6 no.3
    • /
    • pp.527-541
    • /
    • 2001
  • This study was conducted to provide basic information on the nutritional status and health status of the rural elderly. The food intake, food habits and others health related factors were surveryed by interview method. The subjects was 200 people(71 male, 129 female) aged over 65 year in the Han-an area. The obtained results as follows; Their average age is 73.5$\pm$5.6. Mean height and weight of elderly men were 163 cm and 58.1 kg. respectively and 148.7 cm and 50.0 kg for women. The regularity appetite and frequency of eating snacks and eating out were higher in men than in women. The favorite snacks for men were alcohol fruit coffee and for women was fruit, candy, cookies and coffee. The daily alcohol drinking and smoking ration were 50.0%, 60.6% for men, respectively and 14.0%, 24.8 % for women. The nutritional intake ratio to RDA of men was significantly higher than women. Especially, the intakes of energy, Ca, Vit.A, Vit B$_1$, Vit B$_2$ niacin were extremely low in women. The frequency of alcohol intake was related to nutrient intake of women . There was a negative correlation between age. smoking rate and the nutritional intake. The pocket money, weight height appetite, and frequency of snacks showed a positive relation to nutritional intake. In conclusion the study shows that gender did influence food intake in the elderly, Food intake of women was extremely in deficit, because the most elderly rural women live alone. For successful aging. a program for rural elderly is needed on the govermment level, i.e actions to provide minimum economic life, food delivery and psychological/ physical health care through regional pubilc health centers.

  • PDF

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

A Hybrid Link Quality Assessment for IEEE802.15.4 based Large-scale Multi-hop Wireless Sensor Networks (IEEE802.15.4 기반 대규모 멀티 홉 무선센서네트워크를 위한 하이브리드 링크 품질 평가 방법)

  • Lee, Sang-Shin;Kim, Joong-Hwan;Kim, Sang-Cheol
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.4
    • /
    • pp.35-42
    • /
    • 2011
  • Link quality assessment is a crucial part of sensor network formation to stably operate large-scale wireless sensor networks (WSNs). A stability of path consisting of several nodes strongly depends on all link quality between pair of consecutive nodes. Thus it is very important to assess the link quality on the stage of building a routing path. In this paper, we present a link quality assessment method, Hybrid Link Quality Metric (HQLM), which uses both of LQI and RSSI from RF chip of sensor nodes to minimize set-up time and energy consumption for network formation. The HQLM not only reduces the time and energy consumption, but also provides complementary cooperation of LQI and RSSI. In order to evaluate the validity and efficiency of the proposed method, we measure PDR (Packet Delivery Rate) by exchanging multiple messages and then, compare PDR to the result of HQLM for evaluation. From the research being carried out, we can conclude that the HQLM performs better than either LQI- or RSSI-based metric in terms of recall, precision, and matching on link quality.

Comparison of Pectin Hydrogel Collection Methods in Microfluidic Device (미세유체 장치에서 수거 방법에 따른 펙틴 하이드로겔 입자의 특성 비교)

  • Kim, Chaeyeon;Park, Ki-Su;Kang, Sung-Min;Kim, Jongmin;Song, YoungShin;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.740-745
    • /
    • 2015
  • This study investigated the effect of different collection methods on physical properties of pectin hydrogels in microfluidic synthetic approach. The pectin hydrogels were simply produced by the incorporation of calcium ions dissolved in continuous mineral oil. Then, different collection methods, pipetting, tubing, and settling, for harvesting pectin hydrogels were applied. The settling method showed most uniform and monodispersed hydrogels. In the case of settling, a coefficient of variation was 3.46 which was lower than pipetting method (18.60) and tubing method (14.76). Under the settling method, we could control the size of hydrogels, ranging from $30{\mu}m$ to $180{\mu}m$, by simple manipulation of the viscosity of pectin and volumetric flow rate of dispersed and continuous phase. Finally, according to the characteristics of simple encapsulation of biological materials, we envision that the pectin hydrogels can be applied to drug delivery, food, and biocompatible materials.

A Resource Adaptive Data Dissemination Protocol for Wireless Sensor Networks (무선 센서 네트워크를 위한 자원 적응형 데이터 확산프로토콜)

  • Kim, Hyun-Tae;Choi, Nak-Sun;Jung, Kyu-Su;Jeon, Yeong-Bae;Ra, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.2091-2098
    • /
    • 2006
  • In this paper, it proposes a protocol of resource adaptive data dissemination for sensor nodes in a wireless sensor network. In general, each sensor node used in a wireless sensor network delivers the required information to the final destination by conducting cooperative works such as sensing, processing, and communicating each other using the battery power of a independent sensor node. So, a protocol used for transferring the acquired information to users through the wireless sensor network can minimize the power consumption of energy resource given to a sensor node. Especially, it is very important to minimize the total amount of power consumption with a method for handling the problems on implosion. data delivery overlapping, and excessive message transfer caused by message broadcasting. In this paper, for the maintaining of the shortest path between sensor nodes, maximizing of the life time of a sensor node and minimizing of communication cost, it presents a method for selecting the representative transfer node for an event arising area based on the negotiation scheme and maintaining optimal transfer path using hop and energy information. Finally, for the performance evaluation, we compare the proposed protocol to existing directed diffusion and SPIN protocol. And, with the simulation results, we show that the proposed protocol enhances the performance on the power consumption rate when the number of overall sensor nodes in a sensor network or neighbor sensor nodes in an event area are increased and on the number of messages disseminated from a sensor node.

Development of New Device to Improve Sucess Rate of Maze Procedure with Radiofrequency Energy (고주파에너지를 이용한 미로술식의 성적향상을 위한 새로운 기구의 개발)

  • 박남희;유양기;이재원
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.467-473
    • /
    • 2004
  • Background: The sinus conversion rate after the maze procedure in chronic atrial fibrillation using radiofrequency energy is lower than with either conventional 'cut and saw' technique or cryothermia. The creation of incomplete transmural lesions due to poor tissue-catheter contact is thought to be the main cause. To address this problem, the current study was aimed to evaluate the effectiveness of a specially constructed compression device designed to enhance tissue catheter contact during unipolar radiofrequency catheter ablation. Material and Method: Circum-ferential right auricular epicardial lesions were created with a linear radiofrequency catheter in 10 anesthetized pigs. A device specially designed to increase contact by compression of the catheter to the atrial wall was used in 5 pigs (study group). This device was not used in the control group (5 pigs). Conduction block across the right auricular lesion was assessed by pacing, and the transmurality of the lesions were confirmed by microscopic examination. Result: Conduction block was observed in a total of 8 pigs; 5 in study group and 3 in control group. Transmural injury was confirmed microscopically by the accumulation of acute inflammatory cells and loss of elastic fibers in the endocardium. In two pigs with failed conduction block, microscopic examination of the endocardium appeared normal. Conclusion: Failed radiofrequency ablation is strongly related to non-transmural energy delivery. The specially constructed compression device in the current study was successful in creating firm tissue-catheter contact and thereby generating transmural lesions during unipolar radiofrequency ablation.

A Sludge Collector Selection Model by Life Cycle Cost Analysis (LCC분석에 의한 슬러지수집기 선정 모델)

  • Lee, Seung-Hoon;Woo, Yu-Mi;Lee, Sung-Rak;Koo, Kyo-Jin;Hyun, Chang-Taek;Hong, Tae-Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.175-184
    • /
    • 2006
  • This study focused on developing Life Cycle Cost(LCC) analysis model for selecting sludge collectors in wastewater treatment system and applying the model to a case study. Cost items are examined through literature review and historical data of a facility. Analysis period, discount rate, energy cost escalation ratio are assumed to reasonable level. Monetary evaluation is performed using historical data and estimations from vendors. Sensitive analysis is executed using Monte Carlo Simulation for assumed factors. Interviews with operators, vendors, constructors, managers are conducted to define factors which indicates ease of maintenance, ease of delivery, technical performance, efficiency, environmental friendship. Factors are representing technical and social factors. Results from LCC analysis and qualitative analysis are evaluate together with Weighted Matrix Evaluation Methods for optimum alternative of sludge collectors.