• Title/Summary/Keyword: Energy balance flow

Search Result 185, Processing Time 0.022 seconds

Design and Development of Thermoacoustic Rdfrierator : I. Acoustic Analysis of Resonator and Prediction of Energy Conversion (열음향 냉동기의 설계 및 개발 : I. 내부공간의 음향해석 및 에너지 변환 예측)

  • Park, Chul-Min;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.44-52
    • /
    • 1996
  • Acoustical characteristics of internal pipe structures and a loudspeaker of the thermoacoustic refrigerator are analyzed by using the transfer matrix method. The resonator system is dismantled into verious basic acoustic elements, and then linearized transfer matrices are serially combined with the dynamical system of linearized loudspeaker model, that the total system of thermoacoustic refrigerator can be analyzed in terms of frequency characteristics and acoustic field shape. Additionally, by using equations for energy flow through the capillary stack, the temperature distribution over the stack is numerically estimated. After expressing the acoustic work flow, thermoacoustic flow, and energy loss per unit length in a single capillary duct by using the transverse functional variations, overall energy flow rate and energy balance are obtained for the whole capillary stack. The final expression for energy flow through the stack is numerically evaluated by varying physical parameters obtained from the sound field analysis. After confirming good agreements between predicted and experimental results for the interior sound field of a refrigerator model, the thermoacoustic characteristics of Hofler's apparatus is analyzed by the proposed method and it is observed that the results agree well with Hofler's experimental results.

  • PDF

Computer Simulation of an Automotive Air-Conditioning in a Transient Mode

  • Oh, Sang-Han;Won, Sung-Pil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.220-228
    • /
    • 2002
  • The cool-down performance after soaking is very important in an automotive air-conditioning system and is considered as a key design variable. Therefore, transient characteristics of each system component are essential to the preliminary design as well as steady-state performance. The objective of this study is to develop a computer simulation model and ostinato theoretically the transient performance of an automotive air-conditioning system. To do that, the mathematical modelling of each component, such as compressor, condenser, receiver/drier, expansion valve, and evaporator, is presented first of all. The basic balance equations about mass and energy are used in modelling. For detailed calculation, condenser and evaporator are divided into many sub-sections. Each sub-section is an elemental volume for modelling. In models of expansion valve and compressor, dynamic behaviors are not considered in this analysis, but the quasisteady state ones are just considered, such as the relation between mass flow rate and pressure drop in expansion device, polytropic process in compressor, etc. Also it is assumed that there are no heat loss and no pressure drop in discharge, liquid, and suction lines. The developed simulation model is validated by comparing with the laboratory test data of an automotive air-conditioning system. The overall time-tracing properties of each component agreed well with those of test data in this case.

A Study on the Groundwater Flow in Fractured-Porous Media by Flow Resistance Theory (단열-다공암반에서 유동저항 이론을 이용한 지하수 유동 평가에 관한 연구)

  • Han Ji-Woong;Hwang Yong-Soo;Kang Chul-Hyung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.231-238
    • /
    • 2005
  • On the basis of flow resistance theory the conceptual model and related mathematical descriptions is proposed for resistance modeling of groundwater flow in CPM(continuum Porous medium), DFN(discrete fracture network) and fractured-porous medium. The proposed model is developed on the basis of finite volume method assuming steady-state, constant density groundwater flow. The basic approach of the method is to evaluate inter-block flow resistance values for a staggered grid arrangement, i.e. fluxes are stored at cell walls and scalars at cell centers. The balance of forces, i.e. the Darcy law, is utilized for each control volume centered around the point where the velocity component is stored. The transmissivity (or permeability) at the interface is assumed to be the harmonic average of neighboring blocks. Flow resistance theory was utilized to relate the fluxes between the grid blocks with residual pressures. The flow within porous medium is described by three dimensional equations and that within an individual fracture is described by a two dimensional equivalent of the flow equations for a porous medium. Newly proposed models would contribute to develop flow simulation techniques with various matrix characteristics.

  • PDF

Optimal Condition of Specific Impulse for a Liquid Rocket Engine with Film Cooling (막냉각이 적용된 액체로켓엔진의 비추력 최적조건)

  • Cho, Won-Kook;Park, Soon-Young;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.135-140
    • /
    • 2007
  • An analysis has been conducted of the optimal condition to maximize the specific impulse for a liquid rocket engine with film cooling. The present engine performance has been compared with the published conceptual design to be verified satisfactorily accurate. The optimal combination of film coolant flow rate and the regenerative cooling capacity has been found for maximum specific impulse. The optimal fuel pump pressure increases and the optimal film coolant flow decreases for a larger thrust engine. Higher turbine inlet temperature increases both the fuel pump pressure and the film coolant flow rate as the optimal condition. The coking temperature has the same qualitative effect as the turbine inlet temperature.

  • PDF

Development and Demonstration of 150W Fuel Cell Propulsion System for Unmanned Aerial Vehicle (UAV) (무인항공기용 150W급 연료전지 동력원 개발 및 실증)

  • Yang, Cheol-Nam;Kim, Yang-Do
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.300-309
    • /
    • 2012
  • Long endurance is a key issue in the application of unmanned aerial vehicles. This study presents feasibility test results when fuel cell system as an alternative to the conventional engine is applied for the power of the UAV after the 150W fuel cell system is developed and packaged to the 1/4 scale super cub airplane. Fuel cell system is operated by dead-end method in the anode part and periodically purged to remove the water droplet in flow field during the operation. Oxygen in the air is supplied to the stack by the two air blowers. And fuel cell stack is water cooled by cooling circuit to dissipate the heat generated during the fuel cell operation. Weight balance is considered to integrate the stack and balance of plant (BOP) in package layout. In flight performance test, we demonstrated 4 times standalone take-off and landing. In the laboratory test simulating the flight condition to quantify the energy flow, the system is analyzed in detail. Sankey diagram shows that electric efficiency of the fuel cell system is 39.2%, heat loss 50.1%, parasitic loss 8.96%, and unreacted purged gas 1.67%, respectively compared to the total hydrogen input energy. Feasibility test results show that fuel cell system is high efficient and appropriate for the power of UAV.

A Study on Performance of Thermoelectric Air-Cooling System in Parallel Flow (평행유동에서 공랭식 열전모듈 냉각시스템의 성능에 관한 연구)

  • Karng, Sarng-Woo;Shin, Jae-Hoon;Han, Hun-Sik;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.421-429
    • /
    • 2011
  • Experimental and theoretical studies on cooling performance of two-channel thermoelectric air-cooling system in parallel flow are conducted. The effects of operating temperature to physical properties of thermoelectric module (TEM) are experimentally examined and used in the analysis of an air-cooling system considering thermal network and energy balance. The theoretical predicted temperature variation and cooling capacity are in good agreement with measured data, thereby validating analytic model. The heat absorbed rate increases with increasing the voltage input and decreasing thermal resistance of the system. The power consumption of TEM is linearly proportional to mean temperature differences due to variations of the physical properties on operation temperature of TEM. Furthermore thermal resistance of hot side has greater effects on cooling performance than that of cold side.

Numerical Investigation of Energy Separation Process in a Ranque-Hilsch Vortex Tube (Ranque-Hilsch 보텍스 튜브의 에너지 분리 과정에 대한 수치적 고찰)

  • Son, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.42-48
    • /
    • 2008
  • A numerical simulation has been conducted to investigate the physics of the Ranque-Hilsch vortex tube. Even though currently available turbulent models cannot predict such complex flow accurately, it was expected that the simulation would enlighten underlying physics qualitatively. The balance of energy on a fluid particle moving along some typical streamlines through shear work and heat transfer was investigated to explain the physics of energy separation process. It was found that the heat transfer cancels major part of the energy separation done by shear work. It was also found that the most of energy separation occur near inlet and hot outlet.

Cleaner Production System in Dyeing & Finishing Its Approaching Mehods (염색가공분야에서 청정생산활동 접금방법)

  • Lee, Hae-Jung;Nam, Chang-Woo;Park, Young-Hwan
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.87-100
    • /
    • 2003
  • The aim of study was to suggest a methodology for applying cleaner production technology in dyeing & finishing process of textile materials. To accomplish cleaner production, we performed consulting activity in dyeing factory, which composed of following different procedures. First, we organized consulting team with specialists for dyeing, energy and chemicals, and visited dyeing companies for the purpose of doing basic investigation such as analysis of process, chemicals & effluents, condition of equipment and process flow of products. Environmental aspect of raw materials (dyestuff, chemicals) was assessed by TOC, COD, BOD, and effluent of that was assessed by TOC, COD, BOD, TDS and pH. Second, We find out the problems in dyeing&finishing process from the view point of dyeing process, energy, raw materials and process management by utilizing MB (material balance), LCA(Life Cycle Assessment), EB(Energy Balance). Third, we generated the solutions to achieve optimal process condition by brain storming method, and then implemented the solutions to each process. Finally, we determined their effectiveness after considering the results of repeating trials for the solutions. Cleaner production could be achieved by keeping optimal process conditions, equipment modification, improved production management, and on-site reuse or recycling.

  • PDF

An Improved Mechanistic Model to Predict Critical Heat Flux in Subcooled and Low Quality Convective Boiling

  • Kwon, Young-Min;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.236-255
    • /
    • 1999
  • An improved mechanistic model was developed to predict a convective boiling critical heat flux (CHF) in the vertical round tubes with uniform heat fluxes. The CHF formula for subcooled and low quality boiling was derived from the local conservation equations of mass, energy and momentum, together with appropriate constitutive relations. The model is characterized by the momentum balance equation to determine the limiting transverse interchange of mass flux crossing the interface of wall bubbly layer and core by taking account of the convective shear effect due to the frictional drag on the wall-attached bubbles. Comparison between the present model predictions and experimental CHF data from several sources shows good agreement over a wide range of How conditions. The present model shows comparable prediction accuracy with the CHF look-up table of Groeneveld et al. Also the model correctly accounts for the effects of flow variables as well as geometry parameters.

  • PDF

Theoretical Analysis of Steady State Low Current Arcs in Dual Flow Nozzles

  • Song, K.D.;Shin, Y.J.;Lee, H.S.;Kim, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.952-957
    • /
    • 1992
  • When the circuit-breaker switches off, an electric arc is established between the contacts. It is very important to understand the arc characteristics for the design of a circuit breaker. This article describes the theoretical analysis of the arc characteristics by means of energy integral method when convection dominated low current arcs are produced in the dual-airflow nozzle of a model interrupter. In order to investigate the arc radius, the average electric field strength and the arc voltage, the arc column is divided into two regions, and then the energy conservation equation is applied to the arc in each region together with the axial cold flow mass flux function, steady-state mass balance equation and Ohm's law. The results show good agreements with those of other researchers.

  • PDF