• Title/Summary/Keyword: Energy and Consumption

Search Result 6,389, Processing Time 0.036 seconds

Energy Consumption Pattern for Rice Production in Korea (우리나라 벼의 생산과정에서의 에너지사용량 추정)

  • Kim, Y.J.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.1
    • /
    • pp.71-77
    • /
    • 1993
  • This study was conducted in order to figure out the energy consumption pattern in rice production system of Korea, with literature investigation focused on energy requirement in rice production system in worldwide. The investigation reveals that 24,994 MJ/ha was needed to produce 4,500kg of rice production or 5.55 MJ/kg was consumed. The major enegry consumptions are resulted from the application of nitrogen fertilizer, fuel for farm machinery, and farm machinery embodied energy, which showed somewhat different energy consumption pattern than that of the developed country, like, U.S.A. Based on the machinery chosen in this investigation, it was found that 32.7% of the fuel energy, 2,431.8MJ, was consumed in drying operation, 32.2%, 2.402MJ, in tillage and land preparation. 25.8%, 1.923.6MJ in harvest. A linear relationship was found in pre harvest energy input and output of rice production.

  • PDF

Energy Consumption Evaluation for Two-Level Cache with Non-Volatile Memory Targeting Mobile Processors

  • Matsuno, Shota;Togawa, Masashi;Yanagisawa, Masao;Kimura, Shinji;Sugibayashi, Tadahiko;Togawa, Nozomu
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.4
    • /
    • pp.226-239
    • /
    • 2013
  • A number of systems have several on-chip memories with cache memory being one of them. Conventional cache memory consists of SRAM but the ratio of static energy to the total energy of the memory architecture becomes larger as the leakage power of traditional SRAM increases. Spin-Torque Transfer RAM (STT-RAM), which is a variety of Non-Volatile Memory (NVM), has many advantages over SRAM, such as high density, low leakage power, and non-volatility, but it consumes too much writing energy. This study evaluated a wide range of energy consumptions of a two-level cache using NVM partially on a mobile processor. Through a number of experimental evaluations, it was confirmed that the use of NVM partially in the two-level cache effectively reduces energy consumption significantly.

  • PDF

A survey on energy consumption and improvement method for energy conservation - Targeting dwellers in Jecheon city - (사례연구 설문조사에 의한 주택에서의 에너지소비 실태조사와 개선방안 연구 - 제천시 거주 주민을 대상으로 -)

  • Lee, Chul-Goo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • With the architectural energy saving technique such as building insulation, airtightness etc., changing the indoor temperature and shortening the air conditioning time etc. are the good methods to practice energy saving in our lives. This study aims to seek a way to realize energy saving under investigation through a questionnaire survey about energy consumption condition and energy saving perception. 93% of the respondents recognized the need for energy saving, and 67% said more energy saving would possible in homes. Viable energy saving way was questioned by five steps method. More than 50% responded 'possible' or 'seems possible' at most of the items. Whereas less than 50% responded 'possible' or 'seems possible' at the items of 'lessening the cooling time' and 'lessening the shower time'. Ages of 50s who responded 'possible' or 'seems possible' was relatively less compared to 30s and 40s.

A Study on the Characteristic of Energy Consumption in the Super High-rise Mixed-use Housing (초고층 주상복합 아파트의 에너지 소비특성에 관한 연구)

  • Lee, Byunghee;Lee, Jaehyuk;Je, Heaseong;Kang, Dongho
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.63-69
    • /
    • 2010
  • Recently, by the increase of demand on Super High-rise mixed-use housing and it's advanced quality, the interest on it has been raised socially. In accordance with it, the matter of resident's health and energy efficiency has been controversial in terms of living in super high-rise housing. This study started from the idea that it is necessary to have an objective data which that has many residents in narrow space with high density. The purpose of this study are as follows; Firstly, with the quantitative data analysis on energy, it will confirm the objective information on the unclear negative idea of super high-rise mixed-use housing. Secondly, it will establish the fundamental data on the energy of super high-rise mixed-use housing by examining the characteristic of energy consumption of the complex which was built more than 5 years ago. There are 4 methods of this study. Firstly, it follows the steps of theoretical view, and defines concept to study on the characteristic of super high-rise mixed-use housing. Secondly, referring to the previous study, it provides better understanding on th stream of this research and the limit as well to guide the direction in terms of energy consumption. Thirdly, it evaluates the characteristic of monthly consumption by researching the use of electricity energy and heating energy of super high-rise mixed-use housing. The major conclusions of this study are as follows; Firstly, the heating use of apartment complex is same, which is not influenced by the type of the building. Secondly, the electricity use of super high-rise mixed-use housing is from 1,2 to 1.5 as high as the normal apartment.

Development of a New Load Management System Package for Optimal Electricity Consumption Strategy in a Competitive Electricity Market (경쟁적 전력시장에서의 최적 부하소비전략 수립을 위한 새로운 부하관리시스템 패키지 개발)

  • 정구형;이찬주;김진호;김발호;박종배
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.187-197
    • /
    • 2004
  • This paper presents a window-based load management system (LMS) developed as a decision-making tool in the competitive electricity market The developed LMS can help the users to monitor system load patterns, analyze their past energy consumption and schedule for the future energy consumption. The LMS can also provide the effective information on real-time energy/cost monitoring, consumed energy/cost analysis, demand schedule and cost-savings. Therefore. this LMS can be used to plan the optimal demand schedule and consumption strategy.

The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System (냉방시스템의 운전조건에 따른 에너지 소비특성 연구)

  • Park, Gi-Tae;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

A Study on the Applicability of ENERWATER for Evaluation of the Energy Consumption Label of WWTPs in Korea (국내 하수처리시설 에너지 등급 평가를 위한 ENERWATER의 적용 가능성에 관한 연구)

  • Park, Minoh;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.5
    • /
    • pp.231-239
    • /
    • 2022
  • In this study, we applied ENERWATER to evaluate the energy consumption labeling of wastewater treatment plants in Korea using the Korea sewerage statistics data. The results showed that the energy label status was excellent in the SBR process for small and medium-scale wastewater treatment plants and the A2O process for large-scale wastewater treatment plants. The energy labeling of wastewater treatment plants of 50,000 tons capacity was excellent. The statuses of metropolitan cities and Jeollanam-do province were excellent. We analyzed the effects of renewable energy on wastewater treatment plants' energy consumption and found out that digestion gas for large-scale plants and photovoltaic energy for small-scale plants were effective in improving energy labeling. In addition, we compared the energy labels of four wastewater treatment plants in "Z" city and wastewater treatment plant "X" had the best energy label, and the wastewater treatment plants "V" and "Y" had to be selected as priorities for the energy diagnosis and improvement project. In a comprehensive conclusion, the applicability of ENERWATER was confirmed based on sewage statistics data and labeling can be used to set priorities for the energy diagnosis and improvement project.

Routing Protocol for Wireless Sensor Networks Based on Virtual Force Disturbing Mobile Sink Node

  • Yao, Yindi;Xie, Dangyuan;Wang, Chen;Li, Ying;Li, Yangli
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1187-1208
    • /
    • 2022
  • One of the main goals of wireless sensor networks (WSNs) is to utilize the energy of sensor nodes effectively and maximize the network lifetime. Thus, this paper proposed a routing protocol for WSNs based on virtual force disturbing mobile Sink node (VFMSR). According to the number of sensor nodes in the cluster, the average energy and the centroid factor of the cluster, a new cluster head (CH) election fitness function was designed. At the same time, a hexagonal fixed-point moving trajectory model with the best radius was constructed, and the virtual force was introduced to interfere with it, so as to avoid the frequent propagation of sink node position information, and reduce the energy consumption of CH. Combined with the improved ant colony algorithm (ACA), the shortest transmission path to Sink node was constructed to reduce the energy consumption of long-distance data transmission of CHs. The simulation results showed that, compared with LEACH, EIP-LEACH, ANT-LEACH and MECA protocols, VFMSR protocol was superior to the existing routing protocols in terms of network energy consumption and network lifetime, and compared with LEACH protocol, the network lifetime was increased by more than three times.

Mechanical energy consumption of a four-legged walking vehicle (4 각보행로보트의 기계적 에너지 소모량)

  • 홍형주;김진연;윤용산
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.63-68
    • /
    • 1987
  • In this study, a pantograph leg of the four legged walking vehicle is analysed with regard to mechanical energy consumption. Energy efficiency of the vehicle is estimated in terms of specific resistance varying body height, stride length and walking speed. The interaction between specific resistance and the parameters is investigated.

  • PDF

ePRO-OMP: A Tool for Performance/Energy PRofiler and Analyzer for OpenMP Applications (ePRO-OMP: OpenMP 응용 프로그램의 성능 및 에너지 분석 도구)

  • Lee, Young-Ho;Kim, Jihong
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.5
    • /
    • pp.287-293
    • /
    • 2011
  • As chip multiprocessors have been widely adopted in embedded systems, achieving both high performance and low power consumptions of parallel applications becomes challenging. In order to meet these requirements, it is crucial for developers to analyze the performance and energy consumption of parallel applications. In this paper, we propose a tool for profiling and optimizing the performance and energy consumption of OpenMP applications (energy PROfiler and analyzer for OpenMP: ePRO-OMP). The main advantage of ePRO-OMP is that it can analyze both the performance and energy consumption of each parallel region of an OpenMP application, which can help developers find the bottleneck of parallel applications in detail.