• Title/Summary/Keyword: Energy and Consumption

Search Result 6,389, Processing Time 0.039 seconds

Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories - (BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 -)

  • Jun, Jae-Hong;Park, hye-Jin;Lee, Kweon-Hyung;Choo, Seoung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

Quantifying Energy Consumption to the Level of Service Pressure in Water Distribution Network

  • Marlim, Malvin S.;Choi, Jeongwook;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.458-458
    • /
    • 2022
  • It is essential to reduce global carbon emissions, mainly from energy use. The water supply and distribution sector is a vital part of human society and is one of the primary energy consumers. The procurement and distribution of water require electricity to operate the pump to deliver water to users with sufficient pressure. As the water users are spatially distributed over a wide area, the energy required to deliver water to each user differs depending on the corresponding supplying element (reservoir, tank, pipe, pump, and valve). This difference in energy required for each user also comes with a difference in pressure availability which affects the level of service for individual users and the whole network. Typically, there is a disproportion where users close to the source experience excessively high pressure with low energy consumption. In contrast, remote users need more energy to get the minimum pressure. This study proposes the Energy Return Index (ERI) to quantify the pressure return from particular energy consumption to supply water to each node. The disproportionality can be quantified and identified in the network using the proposed ERI. The index can be applied to optimize the network elements such as pump operation and tank location/size to reach a balanced energy consumption with the appropriate level of service.

  • PDF

How do Energy Consumption, Economic Growth and Logistics Development Interrelate?

  • HE, Yugang
    • Journal of Distribution Science
    • /
    • v.18 no.1
    • /
    • pp.71-83
    • /
    • 2020
  • Purpose: Because the energy consumption, economic growth and logistics development are still the heated topics which have attracted many scholars' interests. Therefore, this paper attempts to analyze the effect of logistics development on the economic growth, explore the effect of the economic growth on energy consumption and to discuss the effect of the logistics development on energy intensity. Research design, data and methodology: Using the panel data over the period 2000-2017 of 156 countries and employing the country & year fixed effect model, system generalized method moments and random effect model, the empirical analyses of this propositions are performed. Results: The empirical findings present that the logistics development is positively related to the economic growth. The energy consumption in the t-1 period and economic growth are positively related to the current energy consumption. The logistics development is negatively related to the energy intensity. Meanwhile, the empirical findings also indicate that there is a great difference about these effects among the four sub-samples (low income 18 countries, low middle income 49 countries, upper middle income 44 countries, high income 49 countries). Conclusions: Based on the evidences in this paper provided, we can find that these variables can affect each other.

Associated Factors on Energy Drink Consumption among Korean High School Students (고등학생의 고카페인 에너지 음료 섭취에 대한 관련 요인)

  • Ra, Jin Suk;Yun, Hee Kyung;Kim, Hye Sun;Ryu, Jeong Lim
    • Journal of the Korean Society of School Health
    • /
    • v.30 no.1
    • /
    • pp.48-58
    • /
    • 2017
  • Purpose: The purpose of this study was to identify the factors associated with energy drink consumption in Korean high school students. Methods: This cross sectional study used the secondary data from the 2015 Adolescent Health Behavior Online Survey. A total of 33,744 high school students were included in the study. Energy drink consumption was measured by asking how often they consumed energy drink during the previous week. Associated factors were categorized into socio-demographic characteristics, psychological characteristics, and health related behavioral characteristics. Complex samples logistic regression was used to analyze the influence of associated factors on energy drink consumption. Results: For socio-demographic characteristics, adolescent boys were likely to consume more energy drink than adolescent girls (Adjusted Odds Ratio [AOR]: 1.351, 95% Confidence Interval [CI]: 1.209~1.510). For psychological characteristics, depressed adolescents were likely to consume more energy drink than their counterparts (AOR: 1.697, 95% CI: 1.537~1.874). For health related behavioral characteristics, cigarette smoking (AOR: 1.336, 95% CI: 1.168~1.528), alcohol drinking (AOR: 1.126, 95% CI: 1.012~1.254), soda drink consumption (AOR: 1.800, 95% CI: 1.565~2.071), sweet drink consumption (AOR: 1.715, 95% CI: 1.431~2.054), and insufficient sleep time a day (AOR: 1.307, 95% CI: 1.197~1.427) were associated with energy drink consumption. Conclusions: In conclusion, energy drink consumption in Korean high school students were associated with such factors as psychological factors (depression) and health related behavioral characteristics (smoking, alcohol, sleep, soda and sweet drink). Thus, intervention programs in schools and communities should focus on these psychological and health related behavioral characteristics.

A Clustering Method Considering the Threshold of Energy Consumption Model in Wireless Sensor Networks (무선 센서 네트워크에서 에너지 소모 모델의 임계값을 고려한 클러스터링 기법)

  • Kim, Jin-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3950-3957
    • /
    • 2010
  • Wireless sensor network is composed of sensor node with limited sources, and to maintain and repair is vexatious once made up. Accordingly it is important matter to maximize the network lifetime by minimizing the energy consumption in wireless sensor network, and utilizing the limited sources efficiently. In this paper, I propose a technique arranging the cluster number with efficiency in clustering method to optimize the energy consumption. The energy usage needed for wireless transmission varies in distance(threshold). This technique reduces the energy consumption considering the threshold when arranging the cluster number. I verify that the clustering method organized through the valid processes outperform the LEACH(Low-Energy Adaptive Clustering Hierarchy) in total energy consumption.

An Energy Consumption Model for Time Hopping IR-UWB Wireless Sensor Networks

  • Hoque, M.E.;Khan, M.A.;Parvez, A.Al;An, Xizhi;Kwak, Kyung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6B
    • /
    • pp.316-324
    • /
    • 2007
  • In this paper we proposed an energy consumption model for IR-UWB wireless sensor networks. The model takes the advantages of PHY-MAC cross layer design, and we used slotted and un-slotted sleeping protocols to compare the energy consumption. We addressed different system design issues that are responsible to energy consumption and proposed an optimum model for the system design. We expect the slotted sleeping will consume less energy for bursty load than that of the un-slotted one. But if we consider latency, the un-slotted sleeping model performs better than the slotted sleeping case.

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

Comparison Analysis of Building's Heating Energy Consumption in the Apartment Complex - Focused on Apartment in Daejeon - (공동주택 단지 내 동별 난방에너지소요량 비교 분석 - 대전지역 아파트단지를 중심으로 -)

  • Jang, Young-Hye;Kim, Jeong-Gook;Kim, Jonghun;Jeong, Hakgeun;Hong, Won-Hwa;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.37-42
    • /
    • 2015
  • Purpose: Apartment is a typical residential type in Korea. In the past, apartment types were very monotonous. But today, the types of complex are changed because personal needs have been diversified and personalized. In order to meet those needs, construction companies are constructing various types of apartments. The more apartment types are diverse, the more the energy problems are taken place. So, the purpose of this study is to solve the problem of energy gap in the same complex through improving the thermal transmittance of wall. Method: Heating energy consumption of Building Energy Efficiency Rating System and heating energy usage of apartment show a similar trend on the graph. In order to identify the best position of heating energy consumption difference reduction, we change the building's U-value of front, back, side walls. Result: In the A complex, maximum and minimum heating energy consumption building's shapes are flat. the best efficiency is side U-value change and the worst is front change. In the E complex, maximum heating energy consumption building's shape is tower and minimum building shape is flat. Consequently, the front and back wall performance change was little effect to reduce energy gap, while the change of side wall's U-value show the great reduction between building's energy consumptions.

Cluster-Based Node Management Algorithm for Energy Consumption Monitoring in Wireless Mobile Ad Hoc Networks (무선 모바일 애드혹 네트워크상에서 에너지 소모 감시를 위한 클러스터 기반의 노드 관리 알고리즘)

  • Lee, Chong-Deuk
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.309-315
    • /
    • 2016
  • The node mobility in the wireless mobile network environment increases the energy consumption. This paper proposes a CNMA (cluster-based node management algorithm) to reduce the energy consumption caused by node mobility, and to prolong the life cycle for cluster member nodes. The proposed CNMA traces the mobility for nodes between cluster header and member, and it analyses the energy capacity as monitoring periodically their relationship. So, it makes a division and merges by analysing the state transition for nodes. This paper is to reduce the energy consumption due to the node mobility. The simulation results show that the proposed CNMA can efficiently control the energy consumption caused by mobility, and it can improve the energy cycle.

Study on Energy Consumption of Air-source, Ground-source and Dual-source Heat Pump during Intermediate Season (공기, 지열 및 복합 열원 열펌프의 중간기 에너지 소비량에 관한 연구)

  • Cho, Yeong Uk;Woo, Tea Ho;Chung, Kwang-Seop;Kim, Youngil
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • This study is to compare energy consumption of air-source, ground-source and dual-source heat pump systems during intermediate season using dynamic simulation. Ground-source heat pump has higher COP than that of air-source but requires additional power consumption of auxiliary equipment such as circulation pump. During intermediate season when the outdoor air temperature is favorable, total COP of air-source heat pump may be greater than that of ground-source when circulation pump power consumption is included. Dual-source heat pump which selects the more favorable heat source is compared with air-source only and ground-source only heat pumps for total power consumption. Results show that power consumption of dual-source heat pump is lower than that of ground-source only by 0.73%.