• 제목/요약/키워드: Energy Window

검색결과 693건 처리시간 0.024초

일사차단용 설비를 이용한 냉방 에너지 절약 방안 (Cooling Energy Saving System using Solar Heat Protection Dvices)

  • 정기범;최상곤
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교 (Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings)

  • 이상춘;최영준;김현기;최율
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.

전기변색 외피시스템 적용 업무공간의 채광 성능 분석 (Daylighting Performance of Office Space Applied with Electrochromic Façade System)

  • 김재향;한승훈
    • 토지주택연구
    • /
    • 제13권1호
    • /
    • pp.131-140
    • /
    • 2022
  • 스마트 윈도우는 건물의 에너지 절감을 실현할 수 있는 신소재 건축 자재이며, 상황에 따라 가시광선 투과율(Visible Light Transmittance), 일사획득계수(Solar Heat Gain Coefficient, g-value)를 자유롭게 조절할 수 있는 특징을 가진다. Electrochromic(EC), Suspended Particle Device(SPD), Polymer Dispersed Liquid Crystal(PDLC) 등이 스마트 윈도우에 해당되며 현재 실용화 단계에 있다. 최근 스마트 윈도우의 VLT 및 g-value 조절 기능을 통해 건축물의 에너지를 절감하는 방법에 대한 연구가 활발하게 진행되고 있으며, 일부 유의미한 결과가 도출되고 있다. 하지만, 건축물의 에너지 절감에 대해서 연구의 영역이 제한되어 있고, 실내 환경에 대한 연구는 다소 부족한 실정이다. 에너지 절감에만 초점을 맞춘 실내 공간은 충분한 쾌적성이 확보되지 않기 때문에 실내 환경에 대한 고려가 요구된다. 따라서 이 연구에서는 사무공간을 기준으로 채광성능(Daylight Performance) 분석이 수행되었다. 세계 각 국의 친환경 건축인증제도인 LEED, BREEAM, CASBEE, G-SEED의 기준을 통해 스마트 윈도우의 VLT 조절에 따른 채광성능 검토가 이루어졌으며, 쾌적한 실내 채광환경을 유지할 수 있는 스마트 윈도우의 VLT 범위에 대한 고찰이 이루어졌다. 분석을 위해 사용된 스마트 윈도우는 VLT 조절 범위가 가장 넓은 EC가 사용되었다. 분석 결과 한국의 친환경 건축인증제도인 G-SEED의 평균주광률을 충족하기 위한 스마트 윈도우의 최소 VLT는 25% 이상으로 나타났으며, 스마트 윈도우의 VLT 조절은 균제도에 유의한 영향을 미치지 않는 것으로 나타났다. 또한, LEED의 실내 최소조도의 기준을 적용할 시 적용되어야 하는 계절 및 향에 대한 스마트 윈도우의 VLT 조절 범위 값이 도출되었다.

국내외 공동주택용 창호의 기준 및 성능 조사 (The investigation into the standards and performances of domestic and foreign windows for an apartment house)

  • 송수빈;김영탁;염성곤;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.330-335
    • /
    • 2008
  • This research aims to investigate the standards and the performances of domestic and foreign windows for and apartment house and to present fundamental data for selecting the optimum window at the step of designing an apartment house. To compare the performances of domestic and foreign windows it is selected 5 major window companies in and 3 major window companies in Japan, and investigated window structure, material, type of opening and closing, window glass and the performances of windows for an apartment house-closing and opening force, repeated closing and opening, thermal resistance, sound transmission loss, air tightness, water tightness, wind resistance. The result of a comparative analysis show that the average thermal resistance of Korean window is higher than Japan's but the average sound transmission loss and water tightness of Korean window is lower than Japan's and the rest of the performances is similar.

  • PDF

태양전지를 이용한 국내 Window Type 광전기화학 수소생산의 경제성 평가 (Economic Evaluation of Domestic Window Type Photoelectrochemical Hydrogen Production Utilizing Solar Cells)

  • 김봉진;김종욱
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.595-603
    • /
    • 2010
  • This paper deals with an economic evaluation of domestic window type photoelectrochemical hydrogen production utilizing solar cells. We make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the initial capital cost, the solar to hydrogen conversion efficiency, and the system duration time. The hydrogen production price of the window type photoelectrochemical system was estimated as 1,168,972 won/$kgH_2$. It is expected that hydrogen production cost can be reduced to 47,601 won/$kgH_2$ if the solar to hydrogen conversion efficiency is increased to 14%, the system duration time is increased to 20,000 hours, and the initial capital cost is decreased to 25% of the current level. We also evaluate the hydrogen production cost of the water electrolysis using the electricity produced by solar cells. The corresponding hydrogen production cost was estimated as 37,838 won/$kgH_2$. The photoelectrochemical hydrogen production is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen conversion efficiency and the system duration time as well as to reduce prices of the system facilities.

창호의 차양 조절에 따른 실내 글레어 평가 (Evaluating Interior Glare Base on Shading Adjustments)

  • 임상훈
    • 한국생활환경학회지
    • /
    • 제20권2호
    • /
    • pp.233-237
    • /
    • 2013
  • Daylighting affects the luminous environment and provides comfortable environment to the occupants. However, excessive daylighting might have negative influences on the visual comfort. Skylight, light intensity and distribution, and insolation could cause glare effects on the occupants. This study analyzed the effect of fenestration on the interior glare effects, and verified luminous environment adjustability through mock up test of conventional fenestration and 'Convergence Window System' by analyzation of luminance, luminance contrast, and glare effect. Consequently, room installed Convergence Window System was improved luminance contrast and PGSV Level.

단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가 (The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance)

  • 조수;김석현;엄재용
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

어휘 그룹화를 이용한 음성인식시스템의 성능향상에 관한 연구 (A Study on the Efficient Speech Recognition System using Database Grouping)

  • 우상욱;권승호;한수양;이동규;이두수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2455-2458
    • /
    • 2003
  • In this paper, the Classification of Energy Labeling has been Proposed. Energy Parameters of input signal which is extracted from each phoneme is labelled. And groups of labelling according to detected energies of input signals are detected. Next, DTW processes in a selected group of labeling. This leads to DTW processing faster than a previous algorithm. In this Method, because an accurate detection of parameters is necessary on the assumption in steps of a detection of speeching duration and a detection of energy parameters, variable windows which are decided by pitch period is used. Extract algorithms don't search for exact frame energy, because 256 frame window-sizes is fixed. For this reason, a new energy extraction method has been proposed. A pitch period is detected firstly; next window scale is decided between 200 frames and 300 frames. The proposed method make it possible to cancel an influence of windows.

  • PDF