• Title/Summary/Keyword: Energy Value

Search Result 6,223, Processing Time 0.033 seconds

The Method of Quantitative Analysis Based on Big Data Analysis for Explanatory Variables Containing Uncertainty of Energy Consumption in Residential Buildings - Focused on Apartment in Seoul Korea (주거용 건물의 에너지 실사용량의 불확실성을 내포한 설명변수 인자에 대한 빅데이터 분석 기반의 정량화 방법 - 서울지역의 공동주택을 중심으로)

  • Choi, Jun-Woo;Ahn, Seung-Ho;Park, Byung-Hee;Ko, Jung-Lim;Shin, Jee-Woong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: The energy consumption of apartment units is affected by the lifestyle of the residents rather than system technology. In this study the numerical analysis of assumed energy consumption correlation factors with arbitrary value due to uncertainty. It is intended to be used as a simulation correction value which can be utilized as a predicted value of actual energy usage. The correction value of the simulation is set in the developed form of the existing process that derives the actual usage amount. The simulation results used in the existing evaluation system are used to maintain the useful value as the current system evaluation scale and predict the actual capacity. Method: The method of the study is to statistically analyze the data frames of all complexes capable of collecting the annual energy usage and to reconstruct the population by adding the variables that are expected to be correlated. Repeat the data frame configuration with variables that are assumed to be highly correlated with energy use levels. Determine whether there is correlation or not. The intensity of the external characteristics of the building equipment related to the energy consumption is presented as the quantitative value. Result: The correlation between electricity consumption and trading price since 2010 is analyzed as (Correlation coefficient 0.82). These results are higher than (Correlation coefficient 0.79), which is the correlation between residential area and trading price. This paper signifies the starting point of the methodology that broadens the field of view of verification of simulation feasibility limited to the prediction technique focused on the simulation tool and the element technology scope.The diversified phenomenon reproduction method develops the existing energy simulation method.It can be completed with a simulation methodology that can infer actual energy consumption.

An Algorithm for Energy Efficient Cooperative Communication in Wireless Sensor Networks

  • Kumar, K. Senthil;Amutha, R.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.7
    • /
    • pp.3080-3099
    • /
    • 2016
  • In this paper, we propose an algorithm for energy efficient cooperative communication in wireless sensor network (WSN). The algorithm computes the appropriate transmission distance corresponding to optimal broadcast bit error probability, while taking the circuit energy consumption and the number of cooperating nodes into consideration. The algorithm guarantees minimum energy consumption by choosing higher value of bit error probability for cooperative phase and lower value of bit error probability for broadcast phase while maintaining the required end-to-end reliability. The simulation results show that the proposed algorithm provides significant energy saving gain when compared with traditional fixed distance schemes and is suitable for applications demanding energy efficiency with high quality of reception.

Technological Innovation System for Energy Transition in Small Island Developing States: Adaptive Capacity, Market Formation and Policy Direction in the Maldives

  • Mohamed, Shumais
    • Asian Journal of Innovation and Policy
    • /
    • v.11 no.3
    • /
    • pp.293-319
    • /
    • 2022
  • By analyzing the adaptive capacity, market formation and policy direction as functional areas of Technological Innovation System (TIS), the article evaluates the progress of renewable energy transition in the Maldives, with the inclusion of ideas from Mauritius and Cabo Verde. On the policy direction in the Maldives, technology roadmaps produced with assistance from International Renewable Energy Agency (IRENA) and Asian Development Bank (ADB) are evaluated. Although there are inducing factors such as the Solar Risk Management Initiative, the progress of energy transition is hindered by the lack of technical capacity and local value chain. The findings indicate the importance of facilitating and establishing industry and knowledge networks, incorporating innovation policies, greater involvement of the local private sector along with international investors, and taking water-energy nexus to achieve complementary targets. The study adds value to knowledge by offering a simplified TIS framework, with a current insight of the energy transition in Small Island Developing States with a focus on the Maldives.

An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source (공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구)

  • SOON YOUNG JEONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

Effects of Dietary Metabolizable Energy and Lysine on CarcassCharacteristics and Meat Quality in Arbor Acres Broilers

  • Tang, M.Y.;Ma, Q.G.;Chen, X.D.;Ji, C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.12
    • /
    • pp.1865-1873
    • /
    • 2007
  • An experiment was performed to evaluate the effects of dietary metabolizable energy (ME) and lysine on carcass characteristics and meat quality in Arbor Acres (AA) broilers from 1 to 56 days of age. A total of 2,970 1-d-old male broiler chicks were randomly allocated to nine dietary treatments (three ME levels in combination with three lysine levels), and dietary ME and lysine concentrations were formulated by varying corn, soybean meal, tallow, and L-lysine sulfate concentrations. Live body weight (BW), carcass weight (CW), dressing percent, breast muscle weight (BMW), yield of breast muscle, muscle color (CIE L*, a*, and b*), pH values 45 min and 24 h postmortem ($pH_{45}$, and $pH_{24}$), meat shear force value (SFV), and water loss rate (WLR) were evaluated. Results showed that live body weight and dressing percent increased (p<0.05) as dietary energy increased. Higher dietary lysine content improved breast muscle weight. Neither carcass weight nor yield of breast muscle was affected by dietary energy or lysine content. Higher ME increased the b* value (p = 0.067) and $pH_{24}$ value (p<0.05), whereas it decreased SFV (p<0.05) and WLR (p = 0.06). Only water loss rate was influenced (p<0.01) by dietary lysine, which was higher in broilers from the high lysine diet as compared to those from medium or low lysine diets. The $pH_{45}$ value and L* value of breast muscle were not affected by ME or lysine. Significant interaction of dietary ME and lysine was found on a* value of breast muscle. These results indicated that dietary ME and lysine had important effects on breast muscle growth and meat quality, however their effects were different. Different concentrations of dietary ME and lysine might be considered to improve meat quality.

A Study of the Relationship between Absorbed Energy and DR Pixel Values Using SPEC-78

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyun;Ho, Dong-Su;Choe, Bo-young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.69-69
    • /
    • 2003
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed energy. The visible light photons are converted into an electric signal in the amorphous silicon photodiode. In order to produce good quality images, we need to understand the detailed behavior of DR detectors in radiation. We, therefore, investigated the relationship between DR outputs and X -ray in terms of absorbed energy, using the SPEC-78, X-ray energy spectrum model. We calculated the total filtration of X-ray equipment measuring air exposure and this value was used in the calculation of absorbed energy. The relationship between DR output and the absorbed energy of the X-ray was obtained by matching the absorbed energy with pixel values of real images under various conditions. It was found that the relationship between these two values was almost linear. The results were verified using phantoms made of water and aluminium. The pixel value of the phantom image was estimated and compared with previous results under various conditions. The estimated pixel value coincided with the results, although the effect of scattered photons introduced some errors.

  • PDF

Evaluation of Neutralization and FAME Conversion of Low-grade Waste Oil as Biodiesel Feedstock (저급 폐유지의 바이오디젤 원료 활용을 위한 중화탈산 및 FAME 전환 가능성 평가)

  • Joon-pyo Lee;Jin-suk Lee;Ji-yeon Park;Min-cheol Kim;Jae-wan Cho;Deog-keun Kim
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.2-10
    • /
    • 2023
  • The current mandatory domestic biodiesel blending ratio is 3.5%, which is planned to be gradually increased to achieve carbon neutrality by 2050. The aim of this study was to improve domestic self-sufficiency in biodiesel raw oil by conducting a technical review on the possibility of utilizing waste oils, such as soup oil, chicken oil, and leather oil, as biodiesel feedstocks. These waste oils have an acid value that is too high to be converted directly into biodiesel. Therefore, a pretreatment to reduce the acid value is necessary. The neutralization process was examined as a potential technology for reducing the acid value. The oil recovery rate of the soup oil after neutralization was significantly low at 37.6 wt%. The oil recovery rates of leather oil and chicken oil were 66.49 wt% and 79.08 wt%, respectively. Based on biodiesel conversion experiment using waste oil with a reduced acid value, the conversions were analyzed as 89 wt%, 91.1 wt%, and 90.5 wt% for soup oil, leather oil, and chicken oil, respectively. Thus, it is technically possible to use soup oil, leather oil, and chicken oil as raw materials for producing biodiesel.

A Study of Correlation between SPT N-value and Exerted Electrical Energy Required for Ground Drilling I : Basic Study (Laboratory Soil Box Test) (지반굴착에 소요되는 전기에너지와 표준관입시험 N값과의 상관관계 연구 I : 기초연구(실내토조실험))

  • Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.45-53
    • /
    • 2012
  • Ground drilling is a common method to conduct site investigation, soil improvement, and pile installation. In the point of construction ground drilling requires electrical energy to drill a hole in ground in which the energy exerts into the motor located on the head of auger and generates rotational power. In this paper it is verified that the exerted electrical energy is closely related to the strength characteristics of ground. Measurement sensors, recording system, and drilling system were developed to obtain exerted motor current and drilling depth and laboratory soil box tests were carried out. The measured motor current and boring depth were applied to predict SPT N-value and the prediction results were compared to SPT N-value of laboratory tests. The test results show that the exerted electrical energy to bore ground be a good index to estimate SPT N-value.

Net energy and its establishment of prediction equations for wheat bran in growing pigs

  • Zhiqian, Lyu;Yifan, Chen;Fenglai, Wang;Ling, Liu;Shuai, Zhang;Changhua, Lai
    • Animal Bioscience
    • /
    • v.36 no.1
    • /
    • pp.108-118
    • /
    • 2023
  • Objective: The objective of this experiment was to determine the net energy (NE) value of 6 wheat bran and 1 wheat shorts by indirect calorimetry and establish the NE prediction equations of wheat bran fed to growing barrows. Methods: Forty-eight growing barrows (28.5±2.4 kg body weight) were allotted in a completely randomized design to 8 dietary treatments that included a corn-soybean meal basal diet, 6 wheat bran diets and 1 wheat shorts diet. The inclusion level of wheat bran or wheat shorts in diets is 30%. Results: The addition of wheat bran reduced the apparent total tract digestibility (ATTD) of nutrients (p<0.05). The ATTD of gross energy, crude protein (CP) and dry matter (DM) in the wheat shorts were greater than that in the wheat bran. Addition of wheat bran or wheat shorts had no effect on total heat production and fasting heat production. The NE of wheat bran was negatively correlated with neutral detergent fiber (r = -0.84; p<0.05) and acid detergent fiber (r = -0.83; p<0.05), while it was positively correlated with CP (r = 0.92; p<0.01). The NE values of wheat bran ranged from 6.79 to 8.15 MJ/kg DM, and the NE value of wheat shorts was 12.47 MJ/kg DM. The ratio of NE to metabolizable energy for wheat bran fed to growing pigs was from 66.0% to 71.7%, whereas the value for wheat shorts was 83.7%. Conclusion: The NE values of wheat bran ranged from 6.79 to 8.15 MJ/kg DM, and the NE value of wheat shorts was 12.47 MJ/kg DM. The NE value of wheat bran can be well predicted based on energy content and proximate analysis.

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.