• Title/Summary/Keyword: Energy Value

Search Result 6,223, Processing Time 0.035 seconds

Measuring the matter energy density and Hubble parameter from Large Scale Structure

  • Lee, Seokcheon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.57.1-57.1
    • /
    • 2013
  • We investigate the method to measure both the present value of the matter energy density contrast and the Hubble parameter directly from the measurement of the linear growth rate which is obtained from the large scale structure of the Universe. From this method, one can obtain the value of the nuisance cosmological parameter $\Omo$ (the present value of the matter energy density contrast) within 3% error if the growth rate measurement can be reached $z >3.5$. One can also investigate the evolution of the Hubble parameter without any prior on the value of $H_0$ (the current value of the Hubble parameter). Especially, estimating the Hubble parameter are insensitive to the errors on the measurement of the normalized growth rate $f \sigma_8$. However, this method requires the high $z$ ($z >3.5$) measurement of the growth rate in order to get the less than 5% errors on the measurements of $H(z)$ at $z \leq 1.2$ with the redshift bin $\Delta z = 0.2$. Thus, this will be suitable for the next generation large scale structure galaxy surveys like WFMOS and LSST.

  • PDF

Can Renewable Energy Replace Nuclear Power in Korea? An Economic Valuation Analysis

  • Park, Soo-Ho;Jung, Woo-Jin;Kim, Tae-Hwan;Lee, Sang-Yong Tom
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.559-571
    • /
    • 2016
  • This paper studies the feasibility of renewable energy as a substitute for nuclear and energy by considering Korean customers' willingness to pay (WTP). For this analysis, we use the contingent valuation method to estimate the WTP of renewable energy, and then estimate its value using ordered logistic regression. To replace nuclear power and fossil energy with renewable energy in Korea, an average household is willing to pay an additional 102,388 Korean Won (KRW) per month (approx. US $85). Therefore, the yearly economic value of renewable energy in Korea is about 19.3 trillion KRW (approx. US $16.1 billion). Considering that power generation with only renewable energy would cost an additional 35 trillion KRW per year, it is economically infeasible for renewable energy to be the sole method of low-carbon energy generation in Korea.

Roughage Energy and Degradability Estimation with Aspergillus oryzae Inclusion Using Daisy In vitro Fermentation

  • Chen, C.R.;Yu, B.;Chiou, P.W.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2004
  • The aim of this study was to predict the energy value and dynamic degradation of roughage in Taiwan using the $Daisy^{(R)}$. in vitro fermentation method to provide information on one of the very important nutrients for ration formulation. The second objective was to study the effects of Aspergillus oryzae (AFE) inclusion on nutrient utilization. Three ruminal fistulated dry dairy cows were used for rumen fluid and fifteen conventional forages used in dairy cattle were collected around this island. The degradability of these feedstuffs with and without AFE ($Amaferm^{(R)}$.) treatment was measured using the $Daisy^{(R)}$. in vitro method. The roughage energy values, including TDN and NEL, were calculated according to Robinson (2000). Results from the 30 h in vitro neutral detergent fiber (NDF) degradability and predicted energy evaluations showed that alfalfa (among the forages) contained the highest degradability and energy values, Bermuda straw having the lowest. Peanut vines and corn silage contained higher energy values and the lowest value found in Pangola and Napier grasses among the locally produced forages. Pangola and Napier grasses had lower values than most imported forages except Bermuda straw. Among the by-products, wheat middling contained the highest NDF degradability, while rice bran contained the richest energy value due to its high oil content. From the dynamic dry matter (DM), organic matter (OM), acid detergent fiber (ADF) and neutral detergent fiber (NDF) degradation, corn silage contained the highest effective degradation among the local forages; wheat middling (among the by-products) degraded the fastest in DM, OM, ADF and NDF and showed the highest effective degradability. AFE inclusion was inconsistent among the forages. Alfalfa hay showed significantly increased 30 h NDF degradability and energy values, Pangola hay, Napier grass and brewer's grains showed decreased degradability and energy values. AFE inclusion increased the DM, OM and NDF degradation rate in most forage, but only increased the DM degradation rate in sorghum distiller's grains, the OM degradation rate in bean curd pomace and the NDF and ADF degradation rates in soy pomace (among the by-products).

Temperature Dependence of the Rate Constants of the VV Energy Exchange for N$_2$(v=1)+O$_2$(v=0)$\rightarrow$N$_2$(v=0)+O$_2$(v=1)

  • Ree, Jong-Baik;Chung, Keun-Ho;Kim, Hae-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.241-245
    • /
    • 1986
  • The vibration-vibration energy exchange of $N_2(v=1)+O_2(v=0){\to}N_2(v=0)+O_2(v=1)$ has been investigated, in particular, at low temperatures. The energy exchange rate constants are calculated by use of the solution of the time-dependent Schrodinger equation with the interaction potential of the colliding molecule as a perturbation term. The predicted rate constants are significantly agree with a experimental values in the range of 295∼$90^{\circ}K$. The consideration of the VV-VT coupling decreases the predicted pure VV energy exchange value by a factor of ∼2. When the collision frequency correction is introduced, the VV-VT rate constant is consistent with the observed value in the liquid phase. The consideration of the population of the rotational energy level increases the VV-VT value significantly.

Comparison Analysis of Building's Heating Energy Consumption in the Apartment Complex - Focused on Apartment in Daejeon - (공동주택 단지 내 동별 난방에너지소요량 비교 분석 - 대전지역 아파트단지를 중심으로 -)

  • Jang, Young-Hye;Kim, Jeong-Gook;Kim, Jonghun;Jeong, Hakgeun;Hong, Won-Hwa;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.37-42
    • /
    • 2015
  • Purpose: Apartment is a typical residential type in Korea. In the past, apartment types were very monotonous. But today, the types of complex are changed because personal needs have been diversified and personalized. In order to meet those needs, construction companies are constructing various types of apartments. The more apartment types are diverse, the more the energy problems are taken place. So, the purpose of this study is to solve the problem of energy gap in the same complex through improving the thermal transmittance of wall. Method: Heating energy consumption of Building Energy Efficiency Rating System and heating energy usage of apartment show a similar trend on the graph. In order to identify the best position of heating energy consumption difference reduction, we change the building's U-value of front, back, side walls. Result: In the A complex, maximum and minimum heating energy consumption building's shapes are flat. the best efficiency is side U-value change and the worst is front change. In the E complex, maximum heating energy consumption building's shape is tower and minimum building shape is flat. Consequently, the front and back wall performance change was little effect to reduce energy gap, while the change of side wall's U-value show the great reduction between building's energy consumptions.

The Hammer Energy Delivered to the Drilling Rod in the SPT 1 (표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 1)

  • 조성민;정종홍;김동수;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.469-476
    • /
    • 2001
  • The Ν-value in the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the doughnut hammer with the hydraulic lift system and the automatic trip hammer system were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA) . The rod energy ratio, ΕR$\_$r/ was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ΕR$\_$r/ also varies according to the energy instrumentation system and the analysis methods.

  • PDF

The Hammer Energy Delivered to the Drilling Rod in the SPT 2 (표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 2)

  • 조성민;정종흥;이우진;김동수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.71-78
    • /
    • 2002
  • The N-value from the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the various type of equipment were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA). The rod energy ratio, ERr was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ERr also varies according to the energy instrumentation system and the analysis methods.

  • PDF

Study on Utilizing Resources in Ecopolis - Evaluation of Energy floors of Sewage for Enhanced energy system of residence - (생태도시에서의 자원활용에 관한 연구 - 주택 에너지 시스템 개선을 위한 하수 에너지흐름 분석 -)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.911-919
    • /
    • 2003
  • When the city water was heated for the optimum use of unused energy, the energy flows and losses were calculated and evaluated to improve the value of heated water systems at dwelling side. To obtain this purpose, it was simulated on heat flows under two conditions like with heat pumps or not and calculated the energy sayings. Furthermore, recycling water system was suggested for enhancing the value of heated water system. From this results, the energy flows without heat pumps showed that it was 3-4 percents of heat losses from pipes, 62 percents of energy savings from hot water uses and 34 percents of unutilized heat. When the heated water system adopt the recycling water system at dwelling side, it was improved 12 percents of total energy sayings.

ANALYSIS OF THE LiF:Mg,Cu,Si TL AND THE LiF:Mg,Cu,P TL GLOW CURVES BY USING GENERAL APPROXIMATION PLUS MODEL

  • Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul;Oh, Mi-Ae;Chung, Ki-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.155-164
    • /
    • 2009
  • In this paper, we used computerized glow curve deconvolution (CGCD) software with several models for the simulation of a TL glow curve which was used for analysis. By using the general approximation plus model, parameters values of the glow curve were analyzed and compared with the other models parameters (general approximation, mixed order kinetics, general order kinetics). The LiF:Mg,Cu,Si and the LiF:Mg,Cu,P material were used for the glow curve analysis. And we based on figure of merits (FOM) which was the goodness of the fitting that was monitored through the value between analysis model and TLD materials. The ideal value of FOM is 0 which represents a perfect fit. The main glow peak makes the most effect of radiation dose assessment of TLD materials. The main peak of the LiF:Mg,Cu,Si materials has a intensity rate 80.76% of the whole TL glow intensity, and that of LiF:Mg,Cu,P materials has a intensity rate 68.07% of the whole TL glow intensity. The activation energy of LiF:Mg,Cu,Si was analyzed as 2.39 eV by result of the general approximation plus(GAP) model. In the case of mixed order kinetics (MOK), the activation energy was analyzed as 2.29 eV. The activation energy was analyzed as 2.38 eV by the general order kinetics (GOK) model. In the case of LiF:Mg,Cu,P TLD, the activation energy was analyzed as 2.39 eV by result of the GAP model. In the case of MOK, the activation energy was analyzed as 2.55 eV. The activation energy was analyzed as 2.51 eV by the GOK model. The R value means different ratio of retrapping-recombination. The R value of LiF:Mg,Cu,Si TLD main peak analyzed as $1.12\times10^{-6}$ and $\alpha$ value analyzed as $1.0\times10^{-3}$. The R of LiF:Mg,Cu,P TLD analyzed as $7.91\times10^{-4}$, the $\alpha$ value means different ratio of initial thermally trapped electron density-initial trapped electron density (include thermally disconnected trap electrons density). The $\alpha$ value was analyzed as $9.17\times10^{-1}$ which was the difference from LiF:Mg,Cu,Si TLD. The deep trap electron density of LiF:Mg,Cu,Si was higher than the deep trap electron density of LiF:Mg,Cu,P.

The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance (단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가)

  • Cho, Soo;Kim, Seok-Hyun;Eom, Jae-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.