• Title/Summary/Keyword: Energy Transfer

Search Result 4,178, Processing Time 0.039 seconds

Key Update Protocols in Hierarchical Sensor Networks (계층적 센서 네트워크에서 안전한 통신을 위한 키 갱신 프로토콜)

  • Lee, Joo-Young;Park, So-Young;Lee, Sang-Ho
    • The KIPS Transactions:PartC
    • /
    • v.13C no.5 s.108
    • /
    • pp.541-548
    • /
    • 2006
  • Sensor network is a network for realizing the ubiquitous computing circumstances, which aggregates data by means of observation or detection deployed at the inaccessible places with the capacities of sensing and communication. To realize this circumstance, data which sensor nodes gathered from sensor networks are delivered to users, in which it is required to encrypt the data for the guarantee of secure communications. Therefore, it is needed to design key management scheme for encoding appropriate to the sensor nodes which feature continual data transfer, limited capacity of computation and storage and battery usage. We propose a key management scheme which is appropriate to sensor networks organizing hierarchical architecture. Because sensor nodes send data to their parent node, we can reduce routing energy. We assume that sensor nodes have different security levels by their levels in hierarchy. Our key management scheme provides different key establishment protocols according to the security levels of the sensor nodes. We reduce the number of sensor nodes which share the same key for encryption so that we reduce the damage by key exposure. Also, we propose key update protocols which take different terms for each level to update established keys efficiently for secure data encoding.

Data Dissemination Protocol based on Home Agent and Access Node for Mobile Sink in Sensor Network (센서 네트워크에서 홈에이젼트와 액세스 노드에 기반한 모바일 싱크를 위한 데이터 전송 기법)

  • Lee, Joa-Hyoung;Jung, In-Bum
    • The KIPS Transactions:PartC
    • /
    • v.15C no.5
    • /
    • pp.383-390
    • /
    • 2008
  • The mobile sink is most suitable to guarantee the real time processing to events in ubiquitous environment. However it brings many challenges to wireless sensor networks. In particular, the question of how to transfer the collected data to the mobile sink is an important topic in the aspect of effective management of wireless sensor nodes. In this paper, a new data dissemination model is proposed. Since this method uses the home agent and the access node concepts, it provides reliable and efficient data delivery to mobile sink with minimum overhead. In this proposed method, the information of the mobile sink which is constantly moving is informed only to the home agent node and the access node, instead of all sensor nodes. Thus, the collected data from sensor nodes are transferred to the fixed home agent and it sends these data to the mobile sink. Since the confliction phenomenon between data packets in wireless networks could be reduced, the success ratio of data arriving in the mobile sink is highly enhanced. In our experiments, the proposed method reduces the number of broadcast packets so that it saves the amount of energy consumed for transmitting and receiving the data packets. This effect contributes to prolong the lifetime of the wireless sensor networks operated by batteries.

A Study for Automotive Lamp Manufacturing System Control Composing Ultra melting Process (초음파 접합 공정을 합성한 자동차용 램프 생산시스템 제어에 관한 연구)

  • Lee, Il-Kwon;Kook, Chang-Ho;Kim, Seung-Chul;Kim, Ki-Jin;Han, Ki-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • The purpose of this paper is to study of the vehicle lamp manufacturing system composing ultrasonic waves connection process. Making lamp assembly plant, it was produced in the separate process as the injection molding, ultrasonic waves bonding, annealing in the constant temperature, lamp assembling and packing. But the improvement method producing the lamp was added with one-step process by one automation technique. As a result, welding with ultrasonic waves process, the method decreased the energy consumption and noise during ultrasonic waves welding. Therefore, this method used the mathematics modeling for checking validity, it selected the stability and suitable controller using transfer function of plant and bode chart. In this study, the $180^{\circ}$ revolution control system to turn injection part upside down was $M_{eq}\;lcos{\theta}(t)$ because of gravity influence. It effected to unstable condition a system. For solving this problem, it aimed the linearization and stabilization of system by elimination $M_{eq}\;lcos{\theta}(t)$ as applying Free-forward control technique.

A Study on the Discrepancies of Gas Measurement and the Solution Measures between Suppliers and Consumers in South Korea (도시(都市)가스 계량(計量) 편차(偏差) 및 해소방안(解消方案)에 관(關)한 소고(小考))

  • Park, Sang-Chul;Bang, Sun-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.26-34
    • /
    • 2010
  • KOGAS, established in 1983 by law to ensure stable gas supply to the public, is responsible for the wholesale distribution to 30 city gas companies that deal with the retail distribution of natural gas in their geographic areas. The gas imported by KOGAS is measured by checking the level difference of LNG shipped in tankers before and after unloading. The analysis of gas composition is essential because the imported gas price is determined by its calorific value. The turbine meter is widely used for measuring the gas sold to city gas companies. Unlike the metering system for power plants, there is no gas chromatograph since the custody transfer of gas to the city gas companies is not billed by calorific value, but by volume basis. The gas quantity that a city gas company has bought from KOGAS is not equal to the quantity that the company sold to its customers. There have been some discrepancies between the wholesale gas meter readouts and retail ones due to some inherent errors of meters and some operational issues of the meters. This paper investigates the controversies regarding the real quantity of gas between distributors and consumers. It will discus and suggest desirable policies, both technically and economically, in order to solve the discrepancies of gas measurement.

A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy (태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구)

  • Yoon, Jun-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.324-331
    • /
    • 2013
  • All evacuated tube collector is being constantly studied since it can reduce the conductive heat loss in absorber by using vacuum technology and has advantage of heat transport capacity and quick thermal response in comparatively small temperature difference. This study investigated the dynamic thermal performance of the solar collector with the control condition of solar irradiance and fluid temperature by using performance experimental apparatus which is combined with solar collector and refrigerator, examined the thermal characteristics in definite temperature range of fluid in constant temperature tank by simultaneously measuring refrigerating performance. As a result of it, I deducted the related equation of collector efficiency and found that mean collector efficiency has increased through quick heat transfer characteristics according to increase of outdoor temperature and irradiance in case of outlet temperature of constant temperature tank $22^{\circ}C$ when set outlet temperature of solar collector $25^{\circ}C$ with outlet temperature of constant temperature tank $18^{\circ}C$ & $22^{\circ}C$. Also COP of refrigerator was acquired value of 6.2~7.1 at outlet temperature of constant temperature tank $18^{\circ}C$.

Study on Sludge Reduction by Sludge Solubilization and Change of Operation Conditions of Sewage Treatment Process (하수슬러지 가용화와 하수처리 운전조건 개선을 통한 하수슬러지 발생저감 연구)

  • Choi, In-Su;Jung, Hoe-Suk;Han, Ihn-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1113-1122
    • /
    • 2009
  • In order to find the way to solve the problem of sewage sludge discharge into the ocean, the sludge solubilization by ultrasonic and the improvement methods of wastewater treatment process were studied. In the membrane bioreactor the sludge retention time was stepwise increased from 5.1 day to 442 days where the biomass average concentration has been increased from $c_B$=3.4 $gTSSL^{-1}$ to $c_B$=14.5 $gTSSL^{-1}$ respectively. At the same time, the biomass yield coefficients were reduced from 0.5-0.7 at SRT=5.1 day to 0.005-0.007 at SRT=442 days which means the reduction of sludge production. Oxygen mass transfer coefficients and ${\alpha}$-factor were investigated with changing stirrer speed to find the relation between the high biomass concentration and aeration efficiency in the propeller loop reactor. As a result of sludge solubilization, the solubilization of sludge by ultrasound was increased with increasing energy input and it led to improved anaerobic digestion rate with more biogas production than that of nonsolubilized sewage sludge.

A Study on Thermal Performance Comparison between Large and Small Sized Plate Heat Exchanger (판형 열교환기 크기에 따른 전열성능 비교에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.528-534
    • /
    • 2020
  • The early development and use of plate heat exchangers (PHE) were in response to stringent statutory requirements from dairy products in the late 19th century, but PHEs were not exploited commercially until the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures and pressures, as well as large heat exchanging capacities. The development of current chevron-type corrugated heat plates has been ongoing since the oil shock in the 1970s to improve energy efficiency. The development trend of PHEs is consistent with the development of larger heat plates with better thermal efficiency, lower pressure drop, and good flow distribution. In this study, the thermal performance of small heat plates (PHE-S) and large heat plates (PHE-L) with the same plate depth and corrugation pitch were analyzed experimentally for each channel (H, M, and L type) to suggest development directions of heat plates. The test results showed that for the convectional heat transfer coefficient, the PHE-S was on average, 16.5% higher in the H type, 25% higher in the M type, and 40% higher in the L type than PHE-L. In the case of the pressure drop, the PHE-S was 19% higher in the H type, 46% higher in the M type, and 61% higher in the L type than PHE-L. These results were attributed to the differences in fluid distribution areas between the PHE-S and PHE-L, among other potential causes.

A comparative study of field measurements of the pressure wave with analytical aerodynamic model for the high speed train in tunnels (고속철도 터널내 압력파 측정과 공기압 해석모델에 대한 기초연구)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Hong, Yoo-Jung;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.319-332
    • /
    • 2015
  • The pressure wave formed by the piston effects of the train proceeds within the tunnel when a train enters the tunnel with a high speed. Depending on the condition of tunnel exit, the compression waves reflect at a open end, change to the expansion waves, transfer to tunnel entrance back. Due to interference in the pressure waves and running train, passengers experience severe pressure fluctuations. And these pressure waves result in energy loss, noise, vibration, as well as in the passengers' ears. In this study, we performed comparison between numerical analysis and field experiments about the characteristics of the pressure waves transport in tunnel that appears when the train enter a tunnel and the variation of pressure penetrating into the train staterooms according to blockage ratio of train. In addition, a comparative study was carried out with the ThermoTun program to examine the applicability of the compressible 1-D model(based on the Method of Characteristics). Furthermore examination for the adequacy of the governing equations analysis based on compressible 1-D numerical model by Baron was examined.

Development of a Fuel Cell System Model for a Small Ship (소형 선박용 연료전지 시스템 모델 개발)

  • Bang, Eun-Shin;Kim, Young-Min;Kim, Myoung-Hwan;Park, Sang-Kyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.569-575
    • /
    • 2020
  • In this study, a fuel cell system model for ship power was developed and verified by comparing the experimental results obtained by supplying pure oxygen. To verify the proposed model, the fuel cell output characteristics when oxygen was supplied were compared with those when air was supplied using an air compressor. In addition, the effect of the change in the thermal properties of the fuel cell system on the output of the stack was examined. Within the experimental range of this study, when pure oxygen was supplied as the cathode supply gas, the calculated and experimental voltages and outputs obtained through modeling were almost the same over the entire load range. When air was supplied instead of oxygen for the cathode supply at a constant load of 560 A, each stack voltage was approximately 14 V, the stack output was approximately 8 kW, and the stack efficiency was approximately 3 %. It was confirmed that the overall system efficiency was reduced by approximately 8 %. Among the thermal properties examined in this study, the heat transfer coefficient of the coolant to the stack was found to have the greatest effect on the output of the stack.

Study on Material Characteristics and Firing Temperature of Jar Coffins from Oryang-dong Kiln Site and Jeongchon Tomb, Naju, Korea (나주 오량동 유적 및 정촌 고분 출토 옹관의 재료적 특성 및 소성온도 연구)

  • Kim, Su Kyoung;Jin, Hong Ju;Jang, Sungyoon
    • Journal of Conservation Science
    • /
    • v.34 no.3
    • /
    • pp.179-193
    • /
    • 2018
  • This study is aimed to investigate the provenance of raw materials and firing temperature of jar coffins excavated from the Oryang-dong kiln site and Jeonchon tomb site, Naju, Korea. Most of jar coffin samples shows same range of magnetic susceptibility and have gray color, while 404 and 405 of Jeongchon site are reddish yellow. In some samples fired at high temperature, the water absorption at the mouth rim and body part of same jar coffin were 3.50% and 7.56% respectively. It means that heat transfer and equilibrium in the kiln was not properly continued and the heat energy transferred to the mouth rim and the body part was different. In the petrographic analysis, As a tempering materials, biotite, weathered quartz and feldspar were added in the jar coffins of Oryang-dong site, and biotite, polycrystalline quartz and feldspar in it of Jeongchon site. Tempering materials were found more in the body than in the mouth rim of same jar coffin of Oryang-dong site. It seemed that some samples were fired at over 1,000 to $1,100^{\circ}C$, which showed vitrified texture in the scanning electron images and the rest of samples were fired at below $900^{\circ}C$. Due to similarity of chemical compositions, it is estimated that jar coffins of Jeongchon tomb were produced and supplied from Oryang-dong kiln site. However, the slight difference of some trace elements distribution of samples is attributed to the selection of clay depending on the location.