• 제목/요약/키워드: Energy Transducer

검색결과 192건 처리시간 0.028초

퍼지제어기를 이용한 에어콘 구동용 태양광 발전시스템의 최대전력점추종 방법 (The Maximum Power Point Tracking of Photovoltaic System for Air Conditioning System using Fuzzy Controller.)

  • 강병복;차인수;유권종;정명웅;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.600-602
    • /
    • 1996
  • The purpose of this paper is to develop a new maximum power point tracking(MPPT) using fuzzy set theory for air conditioning system. Fuzzy algorithm based on linguistic rules describing the operator's control strategy is applied to control step-up chopper for MPPT. Fuzzy algorithm is applied to control boost MPPT converter by temperature compensation effect with 8 bit single chip 8051 microcontroller. In this paper, temperature compensation(Becom Transducer : pf-T type) range is $-40^{\circ}C{\sim}+100^{\circ}C$.

  • PDF

Design method for the 2DOF electromagnetic vibrational energy harvester

  • Park, Shi-Baek;Jang, Seon-Jun
    • Smart Structures and Systems
    • /
    • 제25권4호
    • /
    • pp.393-399
    • /
    • 2020
  • In this paper, the design method and experimental validation for the two-degree-of-freedom (2DOF) electromagnetic energy harvester are presented. The harvester consists of the rigid body suspended by four tension springs and electromagnetic transducers. Once the two resonant frequencies and the mass properties are specified, both the constant and the positions for the springs can be determined in the closed form. The designed harvester can locate two resonant peaks close to each other and forms the extended frequency bandwidth for power harvesting. Halbach magnet array is also introduced to enhance the output power. In the experiment, two resonant frequencies are measured at 34.9 and 37.6 Hz and the frequency bandwidth improves to 5 Hz at the voltage level of 207.9 mV. The normalized peak power of 4.587 mW/G2 is obtained at the optimal load resistor of 367 Ω.

Cymbal Type 트랜스듀서를 이용한 압전 발전 장치 (Piezoelectric Generator Using Cymbal Type Transducer)

  • 전호익;정성수;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.169-170
    • /
    • 2008
  • On this paper, piezoelectric generators using piezoelectric ceramics were designed and fabricated. Generators were made by attaching cymbal type metal plates on upper and bottom sides of a disc type piezoelectric ceramic. Generator converts wasting mechanical energy to electrical energy. Output voltage was increased when thickness of ceramic and displacement of vibration were increased. Temperature of the ceramic was increased when it generates, but the temperature rising was saturated at certain temperature.

  • PDF

유속 측정용 초음파 트랜스듀서의 탄성파 에너지 투과율 (Energy Transmission of Elastic Waves in Ultrasonic Transducers for Flow Velocimetry)

  • 박춘광;김대종;김진오;김동현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.733-735
    • /
    • 2014
  • The paper deals with the energy transmission ratio of the elastic waves obliquely transmitting through a plate and a pipe. The incidence angle corresponding to the maximum transmission was determined theoretically and considered in the design of ultrasonic transducers for flow velocimetry. Experimentally-obtained transmission ratios were compared with and confirmed the theoretically-calculated results.

  • PDF

초음파 트랜스듀서의 탄성파 에너지 투과율 (Energy Transmission of Elastic Waves in Ultrasonic Transducers)

  • 박춘광;김대종;김진오
    • 한국소음진동공학회논문집
    • /
    • 제25권2호
    • /
    • pp.124-132
    • /
    • 2015
  • The paper deals with the energy transmission of the elastic waves obliquely transmitting and refracting through a plate and a pipe. By calculating the transmitting ratio depending on the incidence angle, the angle corresponding to the maximum transmission was determined theoretically and considered in the design of ultrasonic transducers for flow velocimetry. Experiments were carried out by using prototypes of the transducers. Experimentally-obtained transmission ratios were compared with and confirmed the theoretically-calculated results.

초음파의 에너지속도와 위상속도의 주행시간 동시성과 이방성 재료의 탄성계수 결정 (Equivalence of the times of flight by ultrasonic energy and phase velocities and determination of the elastic constants of anisotropic materials)

  • 정현조
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.95-103
    • /
    • 1994
  • The purpose of this paper is to provide the experimenters who use the oblique incidence ultrasonic method for anisotropic elastic constants measurement eith some useful relations. In particular, the equivalence of the times of flight by the energy ad phase velocities, which is key to the oblique incidence method, is proved explicitly. This equivalence greatly simplifies the analysis of immersion measurement results. In oredr to correctly measure the transit time of an immersed sample using the oblique incidence, the receiving transducer should be shifted laterally, and an expression in given for this shift. A method for determining all nine elastic constants of an orthotropic material is briefly described and the measurement results are listed for SiC particulate reinforced A1 matrix composites.

  • PDF

평판 구조물의 영상화를 위한 위상 배열 시스템 개발 및 응용 (Development and Application of Phased Array System for Defect Imaging in Plate-like Structures)

  • 이주경;권영의;이흥선;승홍민;김기연;이준규;김회웅;이호철;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.123-130
    • /
    • 2014
  • An ultrasonic magnetostrictive transducer-based phased-array system for imaging defects in plate structures is newly proposed. In that most ultrasonic phased array systems rely on piezoelectric transducers or electromagnetic acoustic transducers, this system has its own unique feature of employing magnetostrictive transducers. Interest in using a phased array system using magnetostrictive transducers has been recently reported for pipe inspection but no such system has been developed for plate inspection. In this investigation, we aim to propose a phased array system using OL-MPTs (Omnidirectional Lamb wave Magnetostrictive Patch Transducers) for plate inspection. The developed system consists of a multi-channel function generator, power amplifiers, preamplifiers and a data acquisition unit. In the process of its development, each of the units must be checked and in doing so, we suggest types of ultrasonic wave experiments that should be carried out. Finally, the phased system using a transducer array composed of eight OL-MPTs is newly configured and is applied for actual crack detection experiments.

와류 현상을 이용하는 호흡기류센서 (Respiratory air Flow Transducer Based on air Turbulence)

  • 김경아;이인광;박준오;이수옥;신은영;김윤기;김경천;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.393-400
    • /
    • 2009
  • The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the devices for cardiopulmonary resuscitation(CPR) procedure. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object existed on the flow stream, but still the flow rate could be evaluated. Computer simulation demonstrated stable turbulence formation big enough to measure. Experiment was followed on the proto-type transducer, the results of which were within ${\pm}5%$ error compared to the simulation data. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999(P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

채낚기 집어등 어선 주변에 유집된 살오징어, Todarodes pacificus의 분포 패턴 (Distribution patterns of the Japanese common squid, Todarodes pacificus attracted around the luring lamp on the jigging boat)

  • 배재현;이경훈;조현정
    • 수산해양기술연구
    • /
    • 제52권3호
    • /
    • pp.276-280
    • /
    • 2016
  • This study investigated luring distributions by water layer of common squid which were targeted by angling fishing vessels equipped with LED and metal-halide lamps using a scientific echosounder with a 120 kHz frequency in order to develop energy-effective underwater fish aggregation devices. In the analysis, angles of a transducer were changed from $0^{\circ}$ to $45^{\circ}$ and were rotated every $10^{\circ}$ horizontally. It was shown that common squid were densely distributed from the surface to 40 m and they were also distributed in directions of $10^{\circ}{\sim}+30^{\circ}$, $-30^{\circ}{\sim}-60^{\circ}$, and $-120^{\circ}{\sim}-130^{\circ}$with the head of vessel as the center. Comparative results of angles of transducer on acoustical densities of common squid distributing in 21~40 m water depth showed an average $101.8m^2/nm^2$ in vertical direction of $0^{\circ}$, $12.3m^2/nm^2$ in angle of $30^{\circ}$, and $42.4m^2/nm^2$ in angle of $45^{\circ}$, respectively. It implied that more considerations on acoustic scattering strength by incidence angle direction of the transducer and swimming oriental angle direction of common squid would be required.

Dynamic Magnetostriction Characteristics of an Fe-Based Nanocrystalline FeCuNbSiB Alloy

  • Chen, Lei;Li, Ping;Wen, Yumei
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.211-215
    • /
    • 2011
  • The dynamic magnetostriction characteristics of an Fe-based nanocrystalline FeCuNbSiB alloy are investigated as a function of the dc bias magnetic field. The experimental results show that the piezomagnetic coefficient of FeCuNbSiB is about 2.1 times higher than that of Terfenol-D at the low dc magnetic bias $H_{dc}$ = 46 Oe. Moreover, FeCuNbSiB has a large resonant dynamic strain coefficient at quite low Hdc due to a high mechanical quality factor, which is 3-5 times greater than that of Terfenol-D at the same low $H_{dc}$. Based on such magnetostriction characteristics, we fabricate a new type of transducer with FeCuNbSiB/PZT-8/FeCuNbSiB. Its maximum resonant magnetoelectric voltage coefficient achieves ~10 V/Oe. The ME output power reaches 331.8 ${\mu}W$ at an optimum load resistance of 7 $k{\Omega}$ under 0.4 Oe ac magnetic field, which is 50 times higher than that of the previous ultrasonic-horn-substrate composite transducer and it decreases the size by nearly 86%. The performance indicate that the FeCuNbSiB/PZT-8/FeCuNbSiB transducer is promising for application in highly efficient magnetoelectric energy conversion.