• Title/Summary/Keyword: Energy Source Type

Search Result 739, Processing Time 0.03 seconds

Analysis of Hot Gas Flew Considering Arc-Flow Interaction (아크플라즈마와 유동간의 상호작용을 고려한 열가스 유동 해석)

  • Kim, Hong-Gyu;Park, Gyeong-Yeop;Bae, Chae-Yun;Jo, Gyeong-Yeon;Jeong, Hyeon-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.3
    • /
    • pp.107-115
    • /
    • 2002
  • This parer presents the analysis of hot gas flow in puffer-type circuit breakers using FVFLIC method. For the analysis of arc-flow interaction, the flow field is analyzed from the equations of conservation for mass, momentum and energy with the assumption of local thermodynamic equilibrium state. The arc is represented as the energy source term composed of ohmic heating and radiation term in the energy conservation equation. Ohmic heating is computed by the electric field analysis only within the conducting plasma region. An approximate radiation transport model is employed for the evaluation of emission and absorption of the radiation. The analysis method was applied to the real circuit breaker model and simulation results such as pressure rise and arc voltage were compared with the experimental ones.

Motion analysis of a VLCO for wave power generation (파력발전용 가변수주진동장치의 운동해석)

  • Lee, Seung-Chul;Goo, Ja-Sam
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.36-41
    • /
    • 2014
  • The structure of a variable liquid column oscillator(a VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. The VLCO is a system absorbing high kinetic energy of accelerated motions of the multiple floating bodies in the effect of air springs occurred by installation of inner air chambers. Thus, VLCO can improve the efficiency of energy than wave energy converters of the activating object type made in Pelamis Company. In this research, the experiment was performed in two models of same draft. The one is that weights were filled, and the other is that water was filled. The numerical results were estimated by assuming that do not exist internal flow, and the results were compared with the results of experiments.

The Control Algorithm of Power-conditioner for Stand-alone PV System (독립형 PV시스템용 전력변환기 제어 알고리즘)

  • 정영석;강기환;김홍성;정명웅;유권종;송진수
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.10a
    • /
    • pp.209-215
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell and battery. Therefore SPVS with charge and discharge controller which can operate solar cell at maximum power point is designed and analyzed by simulation in this paper.

  • PDF

Evaluation of the Reliability of Distribution Power Systems Considering Composite Customer Interruption Cost

  • Choi Sang-Bong;Nam Kee-Young;Kim Dae-Kyeong;Jeong Seong-Hwan;Lee Jae-Duk;Ryoo Hee-Suk
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.286-292
    • /
    • 2005
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that consider the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

The analysis for appropriate value of the input capacitor in dispersed generation PV inverter (PV 분산전원용 인버터의 입력 커패시터 용량 결정을 위한 해석)

  • Lee, Kyung-Soo;Jung, Young-Seck;So, Jung-Hun;Yu, Gwon-Jong;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1362-1364
    • /
    • 2003
  • Most of PV(Photovoltaic) inverters are utilizing voltage source type. Normally in this type, an input capacitor is connected at the input of a inverter to keep dc voltage constant. However, it does not seem to be well known how to determine the appropriate value of the capacitor. By developing non-linear transient analysis, the author suggest an approach to give a guideline. An Implicit trapezoidal formula was used to do this calculation.

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • Pak, Ee-Tong;Jeong, Un-Chul
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.39-47
    • /
    • 1996
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. And arrangement of heating pad play an important role in thermal flow and thermal storage efficiency. In this experiments, number of heating pad is ranged from three, five and nine, and when there is no change on number of heating pad, arrangements are two types of concentration-type and dispersion-type. Strong entrainment take place in the case of concentration-type of heating pad, and rapid temperature rise(${\Delta}{\doteqdot}1.6{\sim}3.2^{\circ}C$) in the tank is obtainable on the concentration-type than dispersion-type. In the constant number of heating pad, the concentration-type has the higher efficiency with about $5{\sim}6%$ than the dispersion-type Therefore, concentration-type of heating pad is an efficient design in constant number of heating pad.

  • PDF

Motion Analysis of A Wind-Wave Energy TLP Platform Considering Second-order Wave Forces

  • Hongbhin Kim;Eun-hong Min;Sanghwan Heo;WeonCheol Koo
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.390-402
    • /
    • 2022
  • Offshore wind energy has become a major energy source, and various studies are underway to increase the economic feasibility of floating offshore wind turbines (FOWT). In this study, the characteristics of wave-induced motion of a combined wind-wave energy platform were analyzed to reduce the variability of energy extraction. A user subroutine was developed, and numerical analysis was performed in connection with the ANSYS-AQWA hydrodynamic program in the time domain. A platform combining the TLP-type FOWT and the Wavestar-type wave energy converter (WEC) was proposed. Each motion response of the platform on the second-order wave load, the effect of WEC attachment and Power take-off (PTO) force were analyzed. The mooring line tension according to the installation location was also analyzed. The vertical motion of a single FOWT was increased approximately three times due to the second-order sum-frequency wave load. The PTO force of the WEC played as a vertical motion damper for the combined platform. The tension of the mooring lines in front of the incident wave direction was dominantly affected by the pitch of the platform, and the mooring lines located at the side of the platform were mainly affected by the heave of the platform.

Parametric Studies for Measurements of Dynamic Properties of Soils Using Inhole type CPTu (인홀형 탄성파콘 시험 결과에 미치는 변수 연구)

  • Jang, In-Sung;Kwon, O-Soon;Kim, Byoung-Il;Lee, Seung-Hyun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.6
    • /
    • pp.523-531
    • /
    • 2008
  • In hole type CPTu equipment which combines the concepts of inhole test method and piezocone test method was newly developed in order to evaluate the dynamic properties of marine soils. It is possible to perform inhole type CPTu without any additional source device because the source and receiver are contained inside the cone rod, which is different from the conventional seismic cone system. In this study, laboratory tests using kaolinite as soft soil and numerical simulations using finite element method were carried out to investigate the effects of several parameters including test methods and soil conditions on the test results from inhole type CPTu and to find out the optimum test method. It was found that it is necessary to maintain the length of swing arm as well as the distance between source and receiver consistently to obtain the rigorous test results. The laboratory test and numerical results also reveal that contrary to the input wave frequency, the water content of soil layer and the disturbance due to the installation of swing arm apparently affect the shear wave velocity.

Simple Contending-type MAC Scheme for Wireless Passive Sensor Networks: Throughput Analysis and Optimization

  • Park, Jin Kyung;Seo, Heewon;Choi, Cheon Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.299-304
    • /
    • 2017
  • A wireless passive sensor network is a network consisting of sink nodes, sensor nodes, and radio frequency (RF) sources, where an RF source transfers energy to sensor nodes by radiating RF waves, and a sensor node transmits data by consuming the received energy. Against theoretical expectations, a wireless passive sensor network suffers from many practical difficulties: scarcity of energy, non-simultaneity of energy reception and data transmission, and inefficiency in allocating time resources. Perceiving such difficulties, we propose a simple contending-type medium access control (MAC) scheme for many sensor nodes to deliver packets to a sink node. Then, we derive an approximate expression for the network-wide throughput attained by the proposed MAC scheme. Also, we present an approximate expression for the optimal partition, which maximizes the saturated network-wide throughput. Numerical examples confirm that each of the approximate expressions yields a highly precise value for network-wide throughput and finds an exactly optimal partition.

A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building (주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Shin, Seung-Ho;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2007
  • This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are $2.7^{\circ}C\;and\;2.5^{\circ}C$ in the summer, $1.5^{\circ}C\;and\;0.5^{\circ}C$ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.