• Title/Summary/Keyword: Energy Source Type

Search Result 739, Processing Time 0.036 seconds

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Development and characteristic study of high brightness ion source using inductively coupled plasma for focused ion beam (유도결합 플라즈마를 이용한 집속이온빔용 고휘도 이온원의 개발 및 특성연구)

  • Kim, Yoon-Jae;Park, Dong-Hee;Hwang, Yong-Seok
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.494-499
    • /
    • 2004
  • A ion source using inductively coupled plasma has been tested in order to test its feasibility as a high brightness ion source for focused ion beam. When operating the ion source with filter magentas in front of plasma electrode for a negative ion source, lower remittances are expected. Extracted beam remittances are measured with an Allison-type scanning device for various plasma parameters and extraction conditions. The normalized omittance has been measured to be around 0.2$\pi$mmmrad with beam currents of up to 0.55 ㎃. In particular, noting that multicusp magnets have a role in decreasing the remittance as well as increasing plasma discharge efficiency, transverse magnetic field has been confirmed to be a useful tool fur decreasing remittance via electron energy control.

  • PDF

A New Approach on the Correction for Compton Escape Component in X-Ray Unfolding Algorithm

  • Kim, Soon-Young;Kim, Jong-Kyung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.925-930
    • /
    • 1995
  • A new approach on the correction for Compton escape component in X-ray unfolding algorithm was investigated to obtain more accurate X-ray source spectrum. The X-ray detector used in this study was a planar type HPGe detector(EG&G ORTEC, GLP-32340/13-P-LP) whose energy response has been blown and ISO narrow beam series were employed as source spectrum. At lower energy Part of measured X-ray spectrum including the correction for Compton escape component more accurate unfolded spectrum was obtained by letting down the starting energy level of the collection in existing spectrum correction procedure to consider multiple scattering effects. It is, from this study, concluded that accurate correction for Compton escape component is needed in X-ray unfolding procedure since Compton scattering becomes more important as incident X-ray energies increase.

  • PDF

Drive Circuit for Switched Reluctance Motor with Flyback Transformer (Flyback Transformer를 갖는 Switched Reluctance Motor의 구동회로)

  • Lim, J.Y.;Cho, K.Y.;Baik, I.C.;Shin, D.J.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.833-836
    • /
    • 1993
  • A flyback type power converter circuit for switched reluctance motor drives is presented. In this converter circuit, the energy extracted from an off going phase is stored in an additional capacitor. The energy stored is used to either be returned to the source frequently or energize the conducting phase during the conduction interval through the transformer. The additional switch to pass the energy stored in the capacitor to the source or the conducting phase is switched under a relatively low voltage condition. Its switching frequency is relatively high so that the size of the transformer can be reduced. The design guideline for the capacitor and the transformer is described. The effectiveness of the presented converter circuit is compared to other circuits through the analysis and experiment.

  • PDF

Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump (직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Woo, Joung-Son;Baik, Young-Jin;Jang, Jea-Chul;Kim, Ji-Young;Ra, Ho-Sang
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

Development of the Energy Harvesting Device using Piezoelectric Generator (압전 발전기를 이용한 에너지 수확 장치 개발)

  • Jun, Ho-Ik;Jeoung, Sung-Su;Chong, Hyon-Ho;Park, Choong-Hyo;Park, Min-Ho;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.439-439
    • /
    • 2009
  • Nowadays, source of MEMS, USN, Hybrid parts pay attention to energy harvesting. On this paper, energy harvesting was studied using piezoelectric effect. And, piezoelectric generator was designed and fabricated. Generators were designed by FEM simulation program and generators were made by attaching cymbal type metal plates on upper and bottom sides of a disc type piezoelectric ceramic. Output AC power was rectified to DC power by full bridge circuit and converted to regular voltage power by DC-DC converter. The final output power was charged to Ni-Cd battery. Using fabricated generators, output voltages dependant on thickness of ceramic, displacement of vibration, frequency of vibration were measured.

  • PDF

Square Pulse-Power Generation Using Capacitor Energy Source (캐패시터를 이용한 구형파 펄스전압발생 전원장치)

  • Rim, Geun-Hie;Choi, Young-Wook;Lee, Hong-Sik;Cho, Chu-Hyun;E.P., Pavlov
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1936-1938
    • /
    • 1997
  • Depending on the energy storage-element they are categorized into two types. One is called voltage-fed type when capacitors are used as energy storage elements. The other goes by the name of current-fed which s utilizes inductors as energy storage elements. This paper deals with the basic concept of pulse-power generation in the view points of load matching for the voltage-fed type.

  • PDF

A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector (Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yu, Chang-Kyun;Yoon, Eung-Sang;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.

Performance Analysis of Tri-gate FinFET for Different Fin Shape and Source/Drain Structures (Tri-gate FinFET의 fin 및 소스/드레인 구조 변화에 따른 소자 성능 분석)

  • Choe, SeongSik;Kwon, Kee-Won;Kim, SoYoung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.71-81
    • /
    • 2014
  • In this paper, the performance variations of tri-gate FinFET are analyzed for different fin shapes and source/drain epitaxy types using a 3D device simulator(Sentaurus). If the fin shape changes from a rectangular shape to a triangular shape, the threshold voltage increases due to a non-uniform potential distribution, the off-current decreases by 72.23%, and the gate capacitance decreases by 16.01%. In order to analyze the device performance change from the structural change of the source/drain epitaxy, we compared the grown on the fin (grown-on-fin) structure and grown after the fin etch (etched-fin) structure. 3-stage ring oscillator was simulated using Sentaurus mixed-mode, and the energy-delay products are derived for the different fin and source/drain shapes. The FinFET device with triangular-shaped fin with etched-fin source/drain type shows the minimum the ring oscillator delay and energy-delay product.

BLOW UP OF SOLUTIONS FOR A PETROVSKY TYPE EQUATION WITH LOGARITHMIC NONLINEARITY

  • Jorge, Ferreira;Nazli, Irkil;Erhan, Piskin;Carlos, Raposo;Mohammad, Shahrouzi
    • Bulletin of the Korean Mathematical Society
    • /
    • v.59 no.6
    • /
    • pp.1495-1510
    • /
    • 2022
  • This paper aims to investigate the initial boundary value problem of the nonlinear viscoelastic Petrovsky type equation with nonlinear damping and logarithmic source term. We derive the blow-up results by the combination of the perturbation energy method, concavity method, and differential-integral inequality technique.