• 제목/요약/키워드: Energy Source

검색결과 5,770건 처리시간 0.03초

공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가 (Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings)

  • 김준석;김종수;전용석
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

공동주택 적용 지열 및 우수열원을 이용한 히트펌프의 실험적 연구 (A Experimental Study on the Ground Source and Rain Water Heat Source Heat Pump System in Apartment)

  • 고건혁;김지영;강은철;이의준;현명택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.833-837
    • /
    • 2008
  • GSHP(Ground Source Heat Pump) has been extensively disseminated due to the recent increasing demand over new and renewable energy. In this study, the operating performance of rain water and ground source heat pump system (RW-GSHP) was compared with GSHP during the heating test. Leaving load temperature(LLT) was $50^{\circ}C$, $53^{\circ}C$, $56^{\circ}C$, respectively and rain water tank temperature(RWT) was $13^{\circ}C$, $15^{\circ}C$, $17^{\circ}C$ in this heating test. The experiment was focused on comparison of the system operating performance depending on leaving load temperature (LLT) and rain water tank temperature (RWT). The results showed that rain water and ground source heat pump system (RW-GSHP) was higher heating performance and COPh than those of GSHP.

  • PDF

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

원예시설의 에너지 부하패턴을 고려한 축열식 지열시스템 설계법에 관한 연구 (Design method of heat storage type ground source heat pump system considering energy load pattern of greenhouse)

  • 유민경;남유진;이광호
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.57-63
    • /
    • 2015
  • Purpose: Ground source heat pump system has been attracted in the horticulture industry for the reduction of energy costs and the increasing of farm income. Even though it has higher initial costs, if it uses in combination with heat storage, it is able to reduce the initial costs and operate efficiently. In order to have significant effect of heat storage type ground source heat pump system, it is required to design the capacity considering various conditions such as energy load pattern and operating schedule. Method: In this study, we have designed heat storage type ground source heat pump system in 5 cases by the operating schedule, and examined the system to find the most economic and having superb performance regarding the system COP(Coefficient of Performance) and energy consumption, using dynamic energy simulation, TRNSYS 17. Result: Conventional ground source heat pump system has lower energy consumption than heat storage type, but following the result of LCC(Life Cycle Cost) analysis, the heat storage type was more economic due to the initial costs. In addition, it has the most efficient performance and energy costs in the case of the smallest heat storage time.

R410A 대체냉매 적용 지열히트펌프 개발 (The development of a ground source heat pump using R410A)

  • 김지동;정봉철;정일권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.99-102
    • /
    • 2008
  • The growth of domestic energy demand is rapidly increased for the industrialization and the improvement of the living standards. It is also recognised that the importance of the use of environmentally friendly energy and high efficient equipment. Ground Source heat pumps(GSHP) using earth as heat source or sink are outstanding environmentally friendly energy systems which have high thermal efficiency when compared to conventional heating and cooling system. So government employs a policy and increase investment for expanding renewable energy market volume. Especially is established a system for obligatory usage of renewable energy to achieve 5% renewable energy diffusion rate by 2011. And the market demand for the ground source heat pump is rapidly growing due to its strong advantages. However domestic situation usually have been depended on the import of ground source heat pumps. In this paper, the results of development of a ground source heat pump using refrigerant R410A are reported.

  • PDF

미활용에너지의 경제적 효과 및 보급지원방안 연구 (Study on Economic analysis and Dessemination Policy of Unused Energy)

  • 안형준;백성권;허은녕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2008
  • Temperature difference energy is a good energy source replacing the fossil fuels. In the study, we classified the temperature difference energy as 4 types by the source & using method. For the understanding economic property of temperature difference energy, we tried simle economic analysis. As the result, Pay back period of 4 case of the temperature difference energy are from 1.23 to 12.65 years. Major factors influenced economic effect are operation time and energy user distance from the temperature difference energy source. If we can select optimal capacity and look for more effient energy users, Temperature difference energy play a important role of replacing fossil energy. So, for dess emination of temperature difference energy, we suggest that temperature difference energy must be included in renewable energy. Applying the effective methods among various promotion program of renewable energy policy, utilization of temperature difference energy could be activated.

  • PDF

공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구 (An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구 (A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods)

  • 차동안;권오경;박차식
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

Lost gamma source detection algorithm based on convolutional neural network

  • Fathi, Atefeh;Masoudi, S. Farhad
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3764-3771
    • /
    • 2021
  • Based on the convolutional neural network (CNN), a novel technique is investigated for lost gamma source detection in a room. The CNN is trained with the result of a GEANT4 simulation containing a gamma source inside a meshed room. The dataset for the training process is the deposited energy in the meshes of different n-step paths. The neural network is optimized with parameters such as the number of input data and path length. Based on the proposed method, the place of the gamma source can be recognized with reasonable accuracy without human intervention. The results show that only by 5 measurements of the energy deposited in a 5-step path, (5 sequential points 50 cm apart within 1600 meshes), the gamma source location can be estimated with 94% accuracy. Also, the method is tested for the room geometry containing the interior walls. The results show 90% accuracy with the energy deposition measurement in the meshes of a 5-step path.