• 제목/요약/키워드: Energy Potential Function

검색결과 363건 처리시간 0.053초

원전 안전필수 계측제어시스템의 주기적 자동고장검출기능에 따른 고장허용 평가모델 (The Fault Tolerant Evaluation Model due to the Periodic Automatic Fault Detection Function of the Safety-critical I&C Systems in the Nuclear Power Plants)

  • 허섭;김동훈;최종균;김창회;이동영
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.994-1002
    • /
    • 2013
  • This study suggests a generalized availability and safety evaluation model to evaluate the influences to the system's fault tolerant capabilities depending on automatic fault detection function such as the automatic periodic testings. The conventional evaluation model of automatic fault detection function deals only with the self diagnostics, and supposes that the fault detection coverage of self diagnostics is always constant. But all of the fault detection methods could be degraded. For example, the periodic surveillance test has the potential human errors or test equipment errors, the self diagnostics has the potential degradation of built-in logics, and the automatic periodic testing has the potential degradation of automatic test facilities. The suggested evaluation models have incorporated the loss or erroneous behaviors of the automatic fault detection methods. The availability and the safety of each module of the safety grade platform have been evaluated as they were applied the automatic periodic test methodology and the fault tolerant evaluation models. The availability and safety of the safety grade platform were improved when applied the automatic periodic testing. Especially the fault tolerant capability of the processor module with a weak self-diagnostics and the process parameter input modules were dramatically improved compared to the conventional cases. In addition, as a result of the safety evaluation of the digital reactor protection system, the system safety of the digital parts was improved about 4 times compared to the conventional cases.

에너지함수를 이용한 실계통에의 과도 안정도 평가 적용 (Transient Stability assessment in the real power system using Energy Function.)

  • 권태원;이경재;이병하;함완균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.153-156
    • /
    • 1992
  • Transient stability analysis of Korea Electric power Corporation(KEPCO) system is conducted by time simulation method, and the method is robust and reliable. But, time simulation consumes enormous computing resources and engineering time, and it does not provide a measure of the degree of stability of the system. Therefore, this method does not apply to every changed condition appropriately and quickly in planning and operating. And Transient Energy Function (TEF) method whis can assess quickly and quantatively the degree of stability of the system and which judges the stability and the instability to analyse transient dynamic charater of the system by mutual changing kinetic energy and potential energy, is developed. TEF method analyses the first Swing transient stability of the system by using the thought that if after disturbance happening, the increase of all the rotator kinetic energy changes into the potential energy after diturbance clearing, the system is stable, otherwise the system is unstable. This paper represents the availabiIity of the TEF method by comparing with time simulation method on the two cases.

  • PDF

부유기 OWC 챔버의 파중 운동해석 (A Study on the Floating OWC Chamber Motion in Waves)

  • 홍도천
    • 한국해양공학회지
    • /
    • 제16권3호
    • /
    • pp.19-27
    • /
    • 2002
  • The motion of a floating OWC chamber in waves is studied taking account of fluctuating air pressure in the air chamber. An atmospheric pressure drop occurs across the upper opening of the chamber which causes not only hydrodynamic but also pneumatic added mass and damping forces to the floating chamber. A velocity potential in the water due to the free surface oscillating pressure patch is added to the conventional radiation-diffraction potential problem. the potential problem inside the chamber is formulated by making use of the Green integral equation associated with the Rankine Green function wile the outer problem with the Kelvin Green function. The two integral equations are solved simultaneously by making use of a matching boundary condition at the lower opening of the chamber to the outer water region. The chamber motion in the frequency domain is calculated for various values of parameters related to the atmospheric pressure drop. The present methods can also be sued for the analysis of air-cushion vehicle motion as well as for the design of a floating OWC wave energy absorber.

부유식 OWC 챔버의 파중 운동해석 (A Study on the Floating OWC Chamber Motion in Waves)

  • 홍도천;홍사영
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.191-197
    • /
    • 2002
  • The motion of a floating OWC chamber in waves is studied taking account of fluctuating.air pressure in the air chamber. An atmospheric pressure drop occurs across the upper opening of the chamber which causes not only hydrodynamic but also pneumatic added mass and damping forces to the floating chamber. A velocity potential in the water due to the free surface oscillating pressure patch is added to the conventional radiation-diffraction potential problem. The potential problem inside the chamber is formulated by making use of the Green integral equation associated with the Rankine Green function while the outer problem with the Kelvin Green function. The two integral equations are solved simultaneously by making use of a matching boundary condition at the lower opening of the chamber to the outer water region. The chamber motion in the frequency domain is calculated for various values of parameters related to the atmospheric pressure drop. The present methods can also be used for the analysis of air-cushion vehicle motion as well as for the design oj a floating owe wave energy absorber.

  • PDF

The Determination of Interconversion Barrers of Oxygen-Containing Cyclohexene Analogues

  • 주재범;이수노;이국행
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권1호
    • /
    • pp.7-11
    • /
    • 1996
  • The interconversion barriers between two twisted conformers of four oxygen-containing cyclohexene analogues have been investigated utilizing a periodic hindered pseudorotational model, molecular mechanics (MM3) calculations, and previously reported far-infrared spectra. The six-fold pseudorotational potential energy function satisfactorily fits the observed bending transitions. The interconversion barrier heights calculated from the pseudorotational model show excellent agreement with those determined from two-dimensional potential energy surfaces for the ring-bending and ring-twisting vibrations. The barriers to interconversion range from 3350 $cm^{-1}$ (9.6 kcal/mol) to 3890 $cm^{-1}$ (11.1 kcal/mol) for four oxygen-containing cyclohexene analogues.

Activation Energy for the Decapsulation of Small Molecules from A-Type Zeolites

  • 김정섭;황계정;홍석봉;노경태
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권3호
    • /
    • pp.280-286
    • /
    • 1997
  • Potential energy function sets for some ion-exchanged A-type zeolites, K-A and Rb11Na1-A, were determined by introducing the X-ray crystal structures as constraints. The potential functions reproduced well the X-ray crystal structures of the monovalent ion-exchanged zeolites. The activation energies for the en- or de-capsulation of small molecules (H2, O2, N2, and CH4) and inert gases from the α-cage of model zeolites (Na-A, K-A, Rb11Na1-A, and Cs3Na9-A) were obtained by the molecular mechanical calculations. The calculated activation energies agreed well with experimental results.

Energy-based Approach to Power Transfer System Analysis

  • Moon, Young-Hyun;Lee, Jong-Gi;Kwon, Yong-Jun
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.227-235
    • /
    • 2004
  • This paper presents a new theoretical approach to energy-based power system analysis for multibus power transmission systems. On the basis of mechanical analogy, an exact energy integral expression is derived for lossy multi-bus systems through rigorous energy analysis. A simple rigid rod model of mechanical power transfer system is introduced to address the physical meanings of potential energy terms associated with transfer conductances as well as transfer susceptances. Finally, energy-based analysis has been proposed to show that the energy function has all information of the power system characteristics.

혼합확률분포를 이용한 복잡지형의 풍력자원 평가 (Wind energy assessment at complex terrain using mixture probability distribution)

  • 송호성;권순덕
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.18-27
    • /
    • 2013
  • This paper presents a method for assessing the wind energy potential at complex terrain using probability distribution. And the proper probability models of the parameters estimating the wind energy are presented. Finally a mixture-Weibull determined by numerical methods procedure are proposed to assess the probability distribution of the energy potential at a site. The developed method is applied to the Kwanjungchun Bridge and compared with wind records which the neighboring weather station.

수중에 잠긴 접지전극주변에서 이온화에 의한 전위저감 및 에너지 방출의 평가 (Evaluation of the potential reduction and energy dispersion caused by ionization phenomena at the submerged ground rod)

  • 안상덕;최종혁;박건훈;양순만;이복희;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2008
  • When high surge voltage invaded into the ground rod contacted with ground water, the ionization phenomena are happened in the water. Although some researchers have surveyed the ionization phenomena in soil, they have just analyzed the variation of the ground resistance. The most important role of the ground rod is to elect human beings from potential rise and to dissipate energy to the earth safely. In this wort we presented the method evaluating the potential reduction and energy dispersion. Also we analyzed theses factors as a function of charging voltages at the water resistivity of $50\;{\Omega}{\cdot}m$ using the Matlab Program. As a result the ground rod potential was reduced to 38 kV by ionization just below breakdown voltage. The energy more than half of the total injected energy was dispersed through the grounding electrode caused due to ionization.

  • PDF