• Title/Summary/Keyword: Energy Estimating

Search Result 749, Processing Time 0.029 seconds

An Estimation of Domestic Regional Energy Efficiency Using Stochastic Distance Function (확률적 거리함수를 활용한 지역별 에너지효율성 추정)

  • Jeong, Dasom;Kang, Sangmok
    • Environmental and Resource Economics Review
    • /
    • v.30 no.4
    • /
    • pp.581-605
    • /
    • 2021
  • The purpose of this study is to provide basic data for improving energy efficiency by estimating the regional energy efficiency in Korea using the stochastic frontier approach beyond the energy intensity that has been traditionally used as an indicator of energy efficiency. In this paper, energy efficiency and energy intensity efficiency were estimated as a stochastic distance function from 1998 to 2018 for 16 cities and provinces in Korea. In addition, the robustness of energy efficiency according to the capital stock estimation methods which had been mixed in previous studies was reviewed. As a result of the analysis, there is a significant change in regional rankings according to the three energy efficiency indicators, so they should be used complementary to each other. Second, while the energy efficiency improved little by little over time, the energy intensity efficiency decreased slightly though. Lastly, energy efficiency by region according to the capital stock estimation method was not robust. Care must be taken in estimating capital stock, which is important in economic analysis.

A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System (지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구)

  • Kang, Shin-Hyung;Lee, Kwang Ho;Do, Sung Lok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.2
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

An algorithm for estimating surface normal from its boundary curves

  • Park, Jisoon;Kim, Taewon;Baek, Seung-Yeob;Lee, Kunwoo
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.67-72
    • /
    • 2015
  • Recently, along with the improvements of geometry modeling methods using sketch-based interface, there have been a lot of developments in research about generating surface model from 3D curves. However, surfacing a 3D curve network remains an ambiguous problem due to the lack of geometric information. In this paper, we propose a new algorithm for estimating the normal vectors of the 3D curves which accord closely with user intent. Bending energy is defined by utilizing RMF(Rotation-Minimizing Frame) of 3D curve, and we estimated this minimal energy frame as the one that accords design intent. The proposed algorithm is demonstrated with surface model creation of various curve networks. The algorithm of estimating geometric information in 3D curves which is proposed in this paper can be utilized to extract new information in the sketch-based modeling process. Also, a new framework of 3D modeling can be expected through the fusion between curve network and surface creating algorithm.

A Suggestion of New Methodology on Thermoeconomics (열경제학에 대한 새로운 방법론 제안)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.315-320
    • /
    • 2009
  • Thermoeconomics or exergoeconomics can be classified into the three fields of cost estimating, cost optimization, and internal cost analysis. The objective of cost estimating is to estimate each unit cost of product and allocate each cost flow of product such as electricity or hot water. The objective of optimization is to minimize the input costs of capital and energy resource or maximize the output costs of products under the given constraints. The objective of internal cost analysis is to find out the cost formation process and calculate the amount of cost flow at each state, each component, and overall system. In this study, a new thermoeconomic methodology was proposed in the three fields. The proposed methodology is very simple and obvious. That is, the equation is only each one, and there are no auxiliary equations. Any energy including enthalpy and exergy can be applied and evaluated by this equation. As a new field, the cost allocation methodology on cool air or hot air produced from an air-condition system was proposed. Extending this concept, the proposed methodology can be applied to any complex system.

  • PDF

An Analysis of the Demand Expansion Options for the Domestic Anthracite Coal (국내 무연탄의 수요개발 가능성 분석)

  • 최기련;강희정
    • Journal of Energy Engineering
    • /
    • v.1 no.1
    • /
    • pp.102-110
    • /
    • 1992
  • The determination of production level of the domestic anthracite coal is an important issue in the national energy strategy. It is also closely related to the energy mix scenarios in the future. The objective of the paper is to discuss and analyze the options of expanding anthracite coal demand in the utility sector. The observed options are including; (1) New pulverized system of the 200 and 500 MW level, (2) Atmospheric Fluidized Bed Combustion (AFBC), and (3) Pressurized Fluidized Bed Combustion (PFBC). Special emphasis is placed on the considerations in estimating the effects on the electric system costs and government subsidies when the options are introduced in the utility sector.

  • PDF

A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building (사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구)

  • Jang, Ji-Hoon;Kim, Hyeonsoo;Auh, Jin-Sun;Leigh, Seung-Bok;Kim, Byungseon-Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

Correlation between Estimated LFG Emission Rate and Actual LFG Extraction Rate for Daegu Bangcheon-ri Landfill Site (대구 방천리 위생 매립장 매립가스 예측 발생량과 실포집량과 상관관계)

  • Lee, Suk-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.721-724
    • /
    • 2007
  • Estimating of LFG emission rate has been well established. But, relatively short history of LFG extraction in Korea, the data and the formular have not been well compared and analyzed. Here, even though the operation period of extraction for Daegu Bangcheon-ri is short, the relevant correlation between estimated and the actual has been tried to find. Hopefully, this will be a guideline for the future LFG forecasting.

  • PDF

Soil Moisture Retrieval Method Utilizing GPS Ground Reflection Signals

  • Young-Joo Kwon;Hyun-Ju Ban;Sumin Ryu;Suna Jo;Han-Sol Ryu;Yerin Kim;Jeong-Eun Park;Yun-Jeong Choi;Kyung-Hoon Han;Yeonjun Kim;Sungwook Hong
    • Journal of the Korean earth science society
    • /
    • v.45 no.4
    • /
    • pp.304-317
    • /
    • 2024
  • This study proposes a soil moisture retrieval method from ground reflection signals received by Global Positioning System (GPS) antenna modules consisting of an up-looking (UP) right-hand circular polarization (RHCP) and two down-looking (DW) RHCP and left-hand circular polarization (LHCP) signals. Field experiments at four different surface types (asphalt, grassland, dry soil, and moist soil) revealed that the DW RHCP and LHCP signals are affected by antenna height and multipath interference signals. The strength differences between the DW LHCP and UP RHCP signals were in good agreement with the DW LHCP signals. Methodologically, this study applied a spectrum analysis to the detrended surface-reflected signals for RHCP and LHCP. The study indicated that the down-looking antenna exhibited greater sensitivity to reflected GPS signals than the up-looking antenna. We demonstrated the feasibility of estimating soil moisture using GPS signals, by comparing LHCP signals received by the down-looking antenna with theoretical values. This study presents a novel method for estimating soil moisture in vegetated areas, leveraging the advantage of cross-polarization comparisons to achieve stronger signal strength than single-polarization reflection signals. With further research, including long-term observations and detailed analysis, the proposed method has the potential to enhance performance significantly.

ESTIMATING THE OPERATOR'S PERFORMANCE TIME OF EMERGENCY PROCEDURAL TASKS BASED ON A TASK COMPLEXITY MEASURE

  • Jung, Won-Dea;Park, Jin-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.415-420
    • /
    • 2012
  • It is important to understand the amount of time required to execute an emergency procedural task in a high-stress situation for managing human performance under emergencies in a nuclear power plant. However, the time to execute an emergency procedural task is highly dependent upon expert judgment due to the lack of actual data. This paper proposes an analytical method to estimate the operator's performance time (OPT) of a procedural task, which is based on a measure of the task complexity (TACOM). The proposed method for estimating an OPT is an equation that uses the TACOM as a variable, and the OPT of a procedural task can be calculated if its relevant TACOM score is available. The validity of the proposed equation is demonstrated by comparing the estimated OPTs with the observed OPTs for emergency procedural tasks in a steam generator tube rupture scenario.