• Title/Summary/Keyword: Energy Estimating

Search Result 749, Processing Time 0.032 seconds

A Detailed Investigation of Solar Radiation Resources in South Korea (남한의 태양에너지 자원 정밀조사)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.59-62
    • /
    • 2011
  • The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth I s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2000. The Result of analysis shows that the armual-average daily global radiation on the horizontal surface is $3.56kWh/m^2/day$ and Estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

  • PDF

Validation study of the NCAR reanalysis data for a offshore wind energy prediction (해상풍력자원 예측을 위한 NCAR데이터 적용 타당성 연구)

  • Kim, Byeong-Min;Woo, Jae-Kyoon;Kim, Hyeon-Gi;Paek, In-Su;Yoo, Neung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Predictions of wind speed for six different near-shore sites were made using the NCAR (National Center for Atmospheric Research) wind data. The distances between the NCAR sites and prediction sites were varied between 40km and 150km. A well-known wind energy prediction program, WindPRO, was used. The prediction results were compared with the measured data from the AWS(Automated Weather Stations). Although the NCAR wind data were located far away from the AWS sites, the prediction errors were within 9% for all the cases. In terms of sector-wise wind energy distributions, the predictions were fairly close to the measurements, and the error in predicting main wind direction was less than $30^{\circ}$. This proves that the NCAR wind data are very useful in roughly estimating wind energy in offshore or near-shore sites where offshore wind farm might be constructed in Korea.

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System (벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가)

  • Suh, Sang-Ho;Kim, Kyungwuk;Kim, Hyoung-Ho;Yoon, In Sik;Cho, Min-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.

A Study on the Calculation Method of Infiltration for Detached Houses (기존 단독주택의 침기량 산정법에 관한 연구)

  • Kim, Giltae;Yoo, Jung-Hyun;Hwang, Ha-Jin;Kim, Kyoung-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.

Analysis of Shadows Effect in Seoul Area for the Estimation of Roof-type PV Power Calculation (지붕형 태양광 발전량 산정을 위한 서울지역 그림자 효과 분석)

  • Yun, ChangYeol;Jung, BoRin;Kim, ShinYoung;Kim, ChangKi;Kim, JinYoung;Kim, HyunGoo;Kang, YongHeack;Kim, YongIl
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.45-53
    • /
    • 2018
  • For the preliminary step for estimating the performance of roof-type photovoltaic system in urban areas, we analyzed the solar radiation reduction ratio by shadow effect by buildings using DSM (Digital Surface Model) and GIS (Geographical Information System) tools. An average loss by the shadow is about 19% in Seoul. The result was related to the building density and distribution. Monthly results show that the winter season (December and January) was more affected by the shading than during the summer season (June and July). It is expected that useful empirical formulas can be made if more detailed correlation studies are performed.

Estimation of Optimal Angle for PV Panels Considering Building's Shadow in Daejeon (대전지역 건물음영을 고려한 PV 최적각도 산정)

  • Lee, Jung-Tae;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol;Kim, Chang Ki;Kim, Jin-Young;Kim, Bo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.43-52
    • /
    • 2020
  • By blocking irradiance, shadows cast by high-rise buildings in urban areas can reduce the power generation efficiency of PV panels installed on low-rise buildings. As the conventionally installed PV panel is not suitable for the urban environment, which is unfavorable for power generating, a more radical solution is required. This study aims to help solve this problem by estimating the optimal PV panel angle. Using the proposed method, the optimal PV angle was calculated by considering shadows that could be cast by nearby buildings throughout the year, and the correlation between solar shading and elevation angle was discovered based on the calculated data.

Design of MAC Protocol for Improving Energy Efficiency and Reducing Transmission Delay in EH-WSN (EH-WSN에서 에너지 효율 향상 및 전송지연 축소를 위한 MAC 프로토콜 설계)

  • Park, Seok Woo;Ra, In-Ho
    • Smart Media Journal
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 2019
  • Recent research on energy harvesting wireless sensor networks focuses on the development of techniques to solve the limited energy resource problem and to extend the whole network life efficiently. Energy harvesting technology can increase the lifetime of a network, but data transmission becomes unavailable when it harvests energy from radio frequency, resulting longer network delay with respect to the increased time in energy harvesting. Therefore, building energy harvesting wireless sensor network should consider the possible network delay as well as the network lifetime problem. In this paper, we propose a new MAC protocol that minimizes end-to-end network delay by adjusting the data transmission time for a packet based on estimating the energy for data transmission along with the amount of traffic flowing into the network and harvested energy. For this goal, it engineers an energy management mechanism that adjusts the sleep time of the network by measuring energy harvesting time. In addition, with simulation results it shows that the proposed MAC protocol improves the performance in terms of energy consumption and end-to-end delay, compared to the existing MAC protocols.

Table-based Effective Estimation of Residual Energy for Battery-based Wireless Sensor System (배터리기반 무선 센서시스템을 위한 테이블기반 잔여 에너지양 추정기법)

  • Kim, Jae-Ung;Noh, Dong-Kun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.9
    • /
    • pp.55-63
    • /
    • 2014
  • Up to date, numerous studies on wireless sensor networks have been performed to overcome the Energy-Constraint of the sensor system. Existing schemes for estimating the residual energy have considered only voltage of sensor system. However battery performance in the real is affected by temperature and load. In this paper we introduce more accurate scheme, for the use in wireless sensor node, based on the interpolation of lookup tables which allow for temperature and load characteristics, as well as battery voltage.

Potential Revenue Prediction Method of ESS using Lithium-ion Battery (리튬이온 배터리를 이용한 에너지저장장치 시스템의 잠재수익 산출 기법)

  • Won, Il-Kuen;Kim, Do-Yun;Jang, Young-Hee;Choo, Kyung-min;Hong, Sung-woo;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.423-424
    • /
    • 2016
  • Recently, the mass production of Energy storage system (ESS) is actively perform around world. Energy storage system is a technique that stores power to energy storage device to supply energy into grid and load at peak-load. Therefore, the efficient energy management is available by using ESS system. The life of Lithium-ion battery is varied corresponding to the power usage, especially selected depth of discharge (DOD). The lifetime of battery is the one of the most issue of the ESS system because of its stability and reliability. Therefore, lifetime management of battery and power converter of ESS module is required. In this paper, the battery lifetime management method estimating residual power and lifetime of lithium ion battery of ESS system is proposed. Also, total avenue prediction of ESS system is simulated considering the total lifetime of battery.

  • PDF

Suggestion of the Worth Evaluation of Cool Air and the Allocation Methodology of Cooling Cost (냉기의 가치평가 및 냉방비 배분방법론 제안)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.201-208
    • /
    • 2009
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. We have suggested new cost allocation methodology as a worth evaluation method in the precedent study, and preformed the worth evaluation and cost allocation on four kind of warm air produced from a heating system as an example. In this study, we applied the suggested method to four kind of cool air, and preformed the worth evaluation and cost allocation on each cool air. As a result, similarly to the precedent study, the more energy a customer saved, the more cooling unit cost decreased, and the more energy a customer consumed, the more cooling unit cost increased. From this analysis, we hope that the suggested methodology can offer a theoretical basis to the energy charge policy of government, and induce the spontaneous energy saving of consumers.