Spatio-temporal Visualization of PM10 Flow Pattern Using Gravity Model (중력모델을 적용한 미세먼지 흐름 패턴 시공간 시각화)
-
- Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
- /
- v.37 no.6
- /
- pp.417-426
- /
- 2019
Conventional visualization of PM (Particulate Matter)10 flows applies superimposition of concentration distribution maps and wind field maps. This method is efficient for small scale maps where only macro flow trends are of interest. However, in the case of urban areas, local flows are difficult to model at micro level using wind fields, and therefore different methods of flow extraction is deemed necessary. In this study, flow information is extracted and visualized directly from the PM10 density data by using the gravity model. This method has the advantage that additional information such as wind field is not necessary for estimating the intensity and direction of PM10 flow. The extracted spatio-temporal flow patterns of PM10 are analyzed with relation to traffic information.
The target system is a middle size UAV, which is a low-speed long-endurance UAV with a weight of 18 kg and wingspan of 6.4 m. Three electric power sources, i.e. solar cells, a fuel cell, and a battery, are considered. The optimal takeoff time is determined to maximize the endurance because the generated solar cell's energy is heavily dependent on it. Each power source is modeled in Matlab/Simulink, and the component models are verified with the component test data. The component models are integrated into a power system which is used for power simulations. When takeoff time is at 6 pm and 2 am, it can supply the power during 37.5 hrs and 27.6 hrs, respectively. In addition, the thermostat control simulation for fuel cell demonstrates that it yields more power supply and efficient power distribution.
This study aims to provide power generating plants with eco-efficiency information. To implement the purposes, of study, both DEA(Data, Envelopment Analysis) model and interview were incorporated in terms of methodologies. To analyze the managerial efficiency, total labor cost and number of employees were considered as input factors. CO2, NOx, and water also were considered as input factors to analyze eco-efficiency. Both annual total power product and annual total revenue were used as output factors. CRS(Constant Return to Scale) and VRS(Variable Return to) model were facilitated in this analysis. According to the findings, most of the power plants were evaluated as 'Efficient'' taking into consideration of average value, both 0.928 from CCR model and 0.969 from VRS model. 7 DMUs including DMU3 and DMU12 are efficient out of 35 DMUs relatively, other DMUs are inefficient. For results of inefficient output factors distribution, it was found that inefficiency for NOx was marked relatively higher than CO2. In order to improve the eco-efficiency in the power plants in the long term, the target amount of Co2 as well as NOx reduction needs to be properly proposed in consideration of particularity of power plants. In the long run, renewable energy, alternative fuels should be adapted to reduce the eco-inefficient.
Although the efficient formation of urban space structure is a key factor in energy saving and environmentally-friendly aspect, the maintenance of the center and sub-center of the city that are key factors has been becoming increasingly difficult due to the variability and complexity of urban activities. In the case of Busan, amid the expansion of urban scale due to rapid economic development and overpopulation, systematic approaches to professional diagnosis and maintenance have been significantly insufficient - other than the city basic plan which has been conducted at an interval of 20 years. For the effective management of urban central area, systematic monitoring of the CBD through demand forecast and blight forecast at a city level must first be implemented. In order to fulfill this goal, this study is to figure out the current state of the CBD through the diagnosis on blight of the urban central area in the viewpoint of rehabilitation of the CBD and to propose the measures for practical utilization of the information about space for the further management of the central area of the city. For analysis, the study looks into the present state in terms of physical index, economic index, and social index. And then as a micro-approach by utilizing economic index, the study has thoroughly examined the economic blight of the Seomyun urban central area of Busan. The outcome of the analysis shows that in terms of population distribution and land utilization the area is in the stage of inefficient dispersion after having gone through the stage of suburbanization. It is expected that this study, as the material that proves the necessity of enhancing the function of the CBD, can propose the direction for the management of the urban center of Busan through blight prediction and management of the urban center and can provide the basic data for the long-term urban development that aims at the efficient strengthening of functions of the CBD.
It is necessary to manage the prediction accuracy of the machine learning model to prevent the decrease in the performance of the grid network condition prediction model due to overfitting of the initial training data and to continuously utilize the prediction model in the field by maintaining the prediction accuracy. In this paper, we propose an automation technique for maintaining the performance of the model, which increases the accuracy and reliability of the prediction model by considering the characteristics of the power grid state data that constantly changes due to various factors, and enables quality maintenance at a level applicable to the field. The proposed technique modeled a series of tasks for maintaining the performance of the power grid condition prediction model through the application of the workflow management technology in the form of a workflow, and then automated it to make the work more efficient. In addition, the reliability of the performance result is secured by evaluating the performance of the prediction model taking into account both the degree of change in the statistical characteristics of the data and the level of generalization of the prediction, which has not been attempted in the existing technology. Through this, the accuracy of the prediction model is maintained at a certain level, and further new development of predictive models with excellent performance is possible. As a result, the proposed technique not only solves the problem of performance degradation of the predictive model, but also improves the field utilization of the condition prediction model in a complex power grid system.
Because the inner environment of greenhouse has a direct impact on crop production, many studies have been performed to develop technologies for controlling the environment in the greenhouse. However, it is difficult to apply the technology developed to all greenhouses because those studies were conducted through empirical experiments in specific greenhouses. It takes a lot of time and cost to develop the models that can be applicable to all greenhouse in real situation. Therefore studies are underway to solve this problem using computer-based simulation techniques. In this study, a model was developed to predict the inner environment of glass greenhouse using CFD simulation method. The developed model was validated using primary and secondary heating experiment and daytime greenhouse inner temperature data. As a result of comparing the measured and predicted value, the mean temperature and uniformity were 2.62℃ and 2.92%p higher in the predicted value, respectively. R2 was 0.9628, confirming that the measured and the predicted values showed similar tendency. In the future, the model needs to improve by applying the shape of the greenhouse and the position of the inner heat exchanger for efficient thermal energy management of the greenhouse.
The purpose of this study was to provide data for the basic research to found the effective conservation and management plan for the Geumdangsil Pine Forest of Yecheon designated as Natural Monument No. 469. Furthermore, this paper suggest efficient sustainable forest preservation and using. In order to achieve the sustainable forest preservation, this study was to analyse topography, land use, tree growth, soil environment, forest usage and forest management, etc. According to analysis the results, the site area is located in the flatlands where is from 130 to 140 m above sea level. The around forest was transformed into agricultural land. The 565 individuals of Pinus densiflora grows in the forest, whereas, 25 trees was cut down or died. There are signs of 25 stumps. The most of 565 trees' diameter at breast height(DBH) was centerized between 30 cm and 50 cm, moreover, the average life expectancy of trees were 85.4 years. The oldest age of tree was estimated to be 200 years. The Sample trees of rate of branch growth is from 4.3 cm to 5.1 cm per year. The middle branch which is more vigorous growth grow 24.2 cm for 3 years. Moreover, the result of soil physico-chemical properties analysis of 7 plots, 4 categories which is soil organic matter, total nitrogen, available phosphoric acid, specific electrical conductance was generally good, however, the 2 categories which is soil pH, exchangeable cation needed improvement. Currently, the site was not pressured by facilities and usage, however, there might be threaten by agriculture such as encroaching on forest. Therefore, there should establish comprehensive ecosystem management such as facility management, visitors management and operation management In this paper considered 4 fields that is ecosystem management, facility management, visitors management and operation management for sustainable management.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70