• Title/Summary/Keyword: Energy Detector

Search Result 904, Processing Time 0.035 seconds

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Selective-Weighted Energy Detector(S-WED) and Synchronization algorithm for IR-UWB systems (IR-UWB 시스템을 위한 선택적 가중치 결합 에너지 검출기(S-WED)와 동기 알고리즘)

  • Ji, Sinae;Kim, Jaeseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.3-9
    • /
    • 2013
  • This paper proposes a selective-weighted energy detection (S-WED) and a synchronization algorithm appropriate for it in IR-UWB system. Energy detectors that are practical in terms of implementation are employed widely for noncoherent reception in IR-UWB systems. However, they show low performance due to using the energy samples captured at symbol rate. For this reason, weighted energy detectors are developed to improve the performance of EDs. Hence, for WED, not only synchronization but also the weight coefficients are needed to be obtained prior to data detection. Meanwhile, the optimal weighting coefficients of WEDs are known to be energy values. Therefore, synchronization and the weighting coefficients can be obtained simultaneously. This paper proposes an S-WED and a simple synchronization algorithm for it in which sub-intervals having energies under a certain level are excluded in energy accumulation resulting in a simpler WED with a bit performance increase in low SNR region. The proposed algorithm is verified through simulations using the preamble symbol and channel models defined in the IEEE 802.15.4a.

Calibration of HEPD on KOMPSAT-1 Using the KCCH Cyclotron

  • Shin, Young-Hoon;Rhee, Jin-Geun;Min, Kyoung-Wook;Lee, Chun-Sik;Lee, Ju-Hahn;Kwon, Young-Kwan;Kim, Jong-Chan;Ha, Jang-Ho;Park, Se-Hwan;Lee, Chang-Hack;Park, H.S.;Kim, Young-Kyun;Chai, Jong-Seo;Kim, Yu-Seong;Lee, Hye-Young
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.289-295
    • /
    • 1999
  • Space Physics Sensor (SPS) on-board the KOMPSAT-1 consists of the High Energy Particle Detector (HEPD) and the Ionospheric Measurement Sensor (IMS). The HEPD is to characterize the low altitude high energy particle environment and the effects on the microelectronics due to these high energy particles. It is composed of four sensors: Proton and Electron Spectrometer(PES), Linear Energy Transfer Spectrometer (LET), Total Dose Monitor (TDM), and Single Event Monitor (SEM). 35 MeV proton beam from the medical KCCH cyclotron, at Korea Cancer Center Hospital in Seoul, is used to calibrate the PES. Primary proton beam of 35MeV scattered by polypropylene target is converted to various energy protons according to the elastic collision kinematics. In this calibration, the threshold level of the proton in the PES can be determined and the energy ranges of PES channels are also calibrated.

System-Level Saturation Modeling of Thermal Imager (열상장비의 포화 현상에 대한 시스템 모델링)

  • Han, Seungoh;Park, Seung-Man
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.698-702
    • /
    • 2016
  • Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.

A Study on the Characteristics of Therapy Radiation Detector with Diode (다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구)

  • 이동훈;지영훈
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.129-138
    • /
    • 1995
  • High-energy and high-dose X-ray and electron beam have been used in radiation therapy after developing particle accelerators. It is recommended to irradiate patients exect real dose for improving therapy effectiveness by International Committee on Radiation Units and Measurement. The radiation detector for daily beam checks of medical accelerators is described. Using thirteen silicon diodes, we have designed the diode detector providing information about calibration, beam symmetry, flatness, stability variation according to radiation damage, time and general quality assurance for both photon and eletron beams. we also compared these measurement values with those of using ionization chamber, film and semiconductor dosimeter.

  • PDF

Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Jeong, Man-Hee;Im, Eun-Kyung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System (IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

Effects of reflector, surface treatment, and length of scintillation crystal on the performance of TOF-DOI PET detector with dual-ended readout

  • Jin Ho Jung;Yong Choi;Johyeon Yun;Jiwoong Jung;Sangwon Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2633-2640
    • /
    • 2024
  • The purpose of this study was to investigate the effect of the reflector, surface treatment, and length of scintillation crystals on the performance of a time-of-flight and depth-of-interaction (TOF-DOI) PET detector with a dual-ended readout and to determine the best reflector and surface treatment. Various types of crystal arrays with three different reflectors (ESR, BaSO4, and Toray), three different lateral surface treatments (all-polished (AP), all-roughened (AR), and partially roughened (PR, three sides polished, and one side roughened)), and two different lengths (20 and 15 mm) were fabricated. The highest light collection efficiency and best energy resolution were achieved using a crystal with a diffuse reflector (BaSO4 for AP and Toray for AR). In contrast, the best coincidence timing resolution (CTR) was achieved using an AR crystal with a specular reflector (ESR). The best DOI resolution was achieved using an AR crystal with BaSO4. Moreover, the results measured with the 20 mm long crystals were similar to those measured with the 15 mm long crystals. Therefore, we concluded that the dual-ended readout PET detector employing the crystal with AR lateral surface treatment and ESR was a good candidate for TOF-DOI PET because it provided excellent CTR and adequate DOI resolution.

Design and Implementation of Concentration Calculation Algorithm for the Infrared Combustible Gas Detector (적외선 가연성 가스검지기의 농도 산출 알고리즘의 설계 및 구현)

  • Han, Seungho;Lyu, Geunjun;Lee, Yeonjae;Kim, Hiesik;Park, Gyoutae
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.145-152
    • /
    • 2016
  • Recently, we can find news about toxic and combustible gas accident. So, we have to develop gas detector that can measure gas at dangerous area for preventing gas accidents. In this paper, we calculate a approximation function from sensor's output using the linear regressiong. And we develop software algorithm using Neville's algorithm for measuring gas concentration. Finally, we compare our algorithm with combustible gas detectors that are already developed, by using standard gas samples manufactured Korea Gas Safety. As a result of this experiment, we confirm that performance of our algorithm is more improved than performance of already developed combustible gas detectors. In the future, we'll research how to improve reliability from using count, temperature and humidity. And we'll design hardware applied explosion proof for safety.

Research on a Operation of a Balise System which Using Solar Energy includes Micro-power Wireless Loop Detector (태양열에너지를 이용한 미소전력 무선 루프 검지기 일체형 발리스 시스템 운영 실험에 관한 연구)

  • Lee, Jeong-jun;Yang, Doh-chul;Kim, Seong Jin;Han, Seung-hee;Park, Kwang-ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.6
    • /
    • pp.150-158
    • /
    • 2016
  • This paper is on a design of a new balise system which has a new functional part of a micro-power inductive wireless loop vehicle detector. The field test has processed and the data has analyzed for check the solar energy operable ability of the detect data interconnect sub-system which includes repeaters and field controllers. Instead of a railroad environment, 12 individual parking-lots are used for field test environment. As a result, in the condition of the designed system and the test environment, it is assumed that under 200 passing vehicles(train or tram) per day can be processed only with solar energy.