Nationwide Reduction of Primary Energy and Greenhouse Gas Emission by PMV Control Considering Individual Metabolic Rate Variations in Apartments (아파트 건물에서 재실자 활동량이 고려된 PMV제어에 따른 연간 국가 차원의 1차 에너지 및 온실가스 감축량 분석)

  • Hong, Sung-Hyup;Do, Sung-Lok;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.37-44
    • /
    • 2018
  • In this study, the effects of considering hourly metabolic rate variations for predicted mean vote (PMV) control on the heating and cooling energy and greenhouse gas emission were investigated. The case adopting PMV control taking the hourly metabolic rate into account was comparatively analyzed against the conventional dry-bulb air temperature control, using a detailed simulation technique. Under the assumption that all the apartments in Korea adopt the PMV control incorporating real-time metabolic rate measurements, nationwide reductions of primary energy and greenhouse gas emission were analyzed. As a result, PMV control considering hourly metabolic rate variations is expected to reduce national primary energy by 6.2% compared to conventional dry-bulb air temperature control, corresponding to reduction of 10,342 GWh. In addition, it turned out that 6.6% of tCO2 emission can be reduced by adopting PMV control, corresponding to nationwide reduction of greenhouse gas emission by approximately 1,720,000 tCO2.

A study on the lighting control system as a demand resources (수요자원으로써의 조명제어시스템 연구)

  • Kim, Jeong-Uk
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.115-121
    • /
    • 2015
  • This paper presents the introduction plan of the renewable energy in innovation city. The introduction plan to make the condition of innovation city best should consider the economical efficiency, the quality of life and the sustainable development. The design of balanced city is demanded to build environment friendly and sustainable city. Energy efficient buildings should be designed to deal with the energy efficiency and environment problem. Therefore, in this paper, we analyze the energy efficiency and provide the method to introduce the renewable energy system, in various buildings. As a result, the renewable energy plans of each innovation city are suggested and analyzed.

Control-Gain Estimation of Energy Dissipation Control Algorithms (에너지소산 제어 알고리듬의 제어이득 산정)

  • Lee Sang Hyun;Kang Sang Hoon;Min Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.343-350
    • /
    • 2004
  • This study is on control gain estimation of energy dissipation control algorithms. Velocity feedback saturated, bang bang, and energy gain control algorithms are proposed based on the Lyapunov stability theory and their performances are evaluated and compared. Saturation problem is considered in the design of the velocity feedback saturated and energy-gain control algorithms, and chattering problem in bang bang control is solved by using boundary layer. Numerical results show that the proposed control algorithms can dissipate the structural energy induced by wind loads efficiently.

Heating and Hot Water Supply Energy Comparison of Medium Capacity and Multi Boilers System applied to Military Officer Housing (군간부 숙소에 적용된 중용량 및 멀티 보일러 시스템의 난방 및 급탕에너지 비교)

  • Kim, Min-Yong;Kim, Young Il;Chung, Kwang Seop
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.8-16
    • /
    • 2014
  • Heating and hot water supply energy consumption of medium and multi boiler systems applied to military officer housing are compared with in-situ experiment and TRNSYS dynamic simulation program. In a multiple boiler system, small capacity boilers are connected in parallel to meet the required capacity. For handling partial loads, medium capacity boiler relies on on-off control, while multi boiler adopts PI control. Since multi boiler has higher efficiency and better control strategy, the results show that energy consumption can be reduced significantly with the multi boiler system.

Energy Management Strategy and Adaptive Control for SMES in Power System with a Photovoltaic Farm

  • Kim, Seung-Tak;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1182-1187
    • /
    • 2014
  • This paper proposes an energy management strategy and adaptive control for superconducting magnetic energy storage (SMES) in a distribution power system with a grid-connected photovoltaic (PV) farm. Application of the SMES system can decrease the output power fluctuations of PV system effectively. Also, it can control the real and reactive powers corresponding to the scheduled reference values with adequate converter capacity, which are required at a steady-state operating point. Therefore, the adaptive control strategy for SMES plays a key role in improving the system stability when the PV generation causes uncertain variations due to weather conditions. The performance of proposed energy management strategy and control method for the SMES is then evaluated with several case studies based on the PSCAD/EMTDC$^{(R)}$ simulation.

An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment (에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석)

  • Park, Sun-Hyo;Kwon, Kyung-Woo;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

Energy Absorbing Control Characteristic of Al Thin-walled Tubes (AL 박육부재의 에너지 흡수 제어특성)

  • Yang, Yong-Jun;Yang, In-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.86-91
    • /
    • 2008
  • The structural members must be designed to control characteristics of energy absorption for protecting passengers in a car accident. Study on collapse characteristics of structural member is currently conducted in parallel with other studies on effective energy absorption capacity of structural members with diverse cross-sectional shapes and various materials. This study concerns the crashworthiness of the widely used vehicle structural members, square thin-walled tubes, which are excellent in the point of the energy absorption capacity. The absorbed energy, mean collapse load and deformation mode were analyzed for side member which absorbs most of the collision energy. To predict and control the energy absorption, controller is designed in consideration of its influence on height, thickness and width ration in this study. The absorbed energy and mean collapse load of square tubes were increased by $15{\sim}20%$ in using the controller, and energy absorbing capability of the specimen was slightly changed by change of the high controller's height.

Demonstration to Operate and Control Frequency Regulation of Power System by 4MW Energy Storage System (4MW 에너지저장장치의 전력계통 주파수 조정 운전제어를 위한 실증)

  • Lim, Geon-Pyo;Han, Hyun-Gyu;Chang, Byung-Hoon;Yang, Seung-Kwon;Yoon, Yong-Beum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.169-177
    • /
    • 2014
  • Operation and control system has been installed and tested to use energy storage system(ESS) for frequency regulation at 4MW class of ESS demonstration facility installed at Jeju island, Korea in 2013. Simulation tests were performed by programing language C# for power system of Jeju island to develop control algorithm. Site simulation tests were performed in control system itself without connecting power system and energy storage system. Control algorithm was coded, modified and tested to load to controller and communication system and human-machine interface were developed and tested in the process of simulation tests. After similar results to that of simulation tests by programing language were obtained, power system and energy storage system demonstration facility were connected to control system by communication system. Energy storage system for frequency regulation was tested for actual frequency and simulation frequency. The site tests showed the similar results to that of simulation tests and the control systems is possible to be operated for frequency regulation. Faster response of energy storage system for frequency regulation, less costs and less capacity of energy storage systems which cover for frequency regulation of power plants. It is expected that more studies for time-reduction and time-delay elements can make less capacity of energy storage system cover more role of frequency regulation of power plants.

A Study of energy conversion by the penetration control in the skin (에너지변환을 이용한 피부의 투과조절에 관한 연구)

  • Kim, Jeong-Lae;Kim, Hye-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • We are confirmed to the variation of the transfer condition and the functional penetration by the permitted conversion energy on the skin. The given conversion energy is consist of the flow level of penetration control and go to the processing transfer in the skin that is to create the modeling for algorithm. The energy level of control processing was achieved effectively modeling system that was the composition of auto and local control level in the epidermis-dermis layer. Their penetration pulse control system was consisted of conversion energy with reference of fixing situation and recreation of designed apparatus for the energy control function that was converted to capacity by the size, form and combination. Also, the system was shown accurately distribution of conversion at the depth of skin correction. Therefore, conversion modeling was established effectively to separate the division parts for conversion system. We will be possible to progress the improvement effectiveness of the skin and to consist of the continuous penetration control system for functional energy on the skin.

Optimal energy saving model for RCL(Re-Coiling Ling) hydraulic system (ICCAS 2003)

  • Yi, Seoung-Ung;Won, Sang-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1736-1740
    • /
    • 2003
  • POSCO Kwang-Yang Works #2 Cold Rolling Mill RCL has the main hydraulic system that controlled on/off control method. In the aspect of the consumption of electrical energy this system has some problem. So, we present a continuous control method instead of on/off control method that controls the pressure of main hydraulic system with saving the electric energy.

  • PDF