• 제목/요약/키워드: Energy Consumption Reduction

검색결과 776건 처리시간 0.028초

노후 보건소의 그린리모델링을 통한 에너지 및 탄소배출 저감효과 분석 (Analysis on the Energy and GHG Emissions Reduction Effect of Old Public Health Centers through Green-remodeling)

  • 조정흠;오진환;강연주;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.18-26
    • /
    • 2023
  • Green-remodeling is to improve the energy performance of existing buildings that have been aged for more than 15 years since completion. In order to achieve the national greenhouse gas emission reduction plan in the building sector, it is necessary to analyze the carbon reduction effect by considering the internal carbon emissions that may occur during green-remodeling of old buildings. This study analyzed the effects of energy reduction and carbon emission reduction when green-remodeling was applied to old health centers constructed in 1992. When applying green-remodeling, the carbon emission reduction effect considered the embodied carbon emission of the improvement items and the carbon emission at the building operation stage. When applying green-remodeling to existing buildings, energy consumption was reduced by 39.3%, and carbon emissions were reduced by 48.9% after 27 years of green-remodeling. In order to reduce carbon emissions, it was important to apply a renewable system as an item to improve the performance of green-remodeling. In particular, it was confirmed that it is very important to consider the photovoltaic system as a top priority for the carbon emission reduction.

피크저감과 특례요금제를 고려한 ESS 경제성 분석 알고리즘에 관한 연구 (A Study on Economic Analysis Algorithm for Energy Storage System Considering Peak Reduction and a Special Tariff)

  • 손준호
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1278-1285
    • /
    • 2018
  • For saving electricity bill, energy storage system(ESS) is being installed in factories, public building and commercial building with a Time-of-Use(TOU) tariff which consists of demand charge(KRW/kW) and energy charge(KRW/kWh). However, both of peak reduction and ESS special tariff are not considered in an analysis of initial cost payback period(ICPP) on ESS. Since it is difficult to reflect base rate by an amount of uncertain peak demand reduction during mid-peak and on-peak periods in the future days. Therefore, the ICPP on ESS can be increased. Based on this background, this paper presents the advanced analysis method for the ICPP on ESS. In the proposed algorithm, the representative days of monthly electricity consumption pattern for the amount of peak reduction can be found by the k­means clustering algorithm. Moreover, the total expected energy costs of representative days are minimized by optimal daily ESS operation considering both peak reduction and the special tariff through a mixed-integer linear programming(MILP). And then, the amount of peak reduction becomes a value that the sum of the expected energy costs for 12 months is maximum. The annual benefit cost is decided by the amount of annual peak reduction. Two simulation cases are considered in this study, which one only considers the special tariff and another considers both of the special tariff and amount of peak reduction. The ICPP in the proposed method is shortened by 18 months compared to the conventional method.

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

Energy Efficient Sequential Sensing in Multi-User Cognitive Ad Hoc Networks: A Consideration of an ADC Device

  • Gan, Xiaoying;Xu, Miao;Li, He
    • Journal of Communications and Networks
    • /
    • 제14권2호
    • /
    • pp.188-194
    • /
    • 2012
  • Cognitive networks (CNs) are capable of enabling dynamic spectrum allocation, and thus constitute a promising technology for future wireless communication. Whereas, the implementation of CN will lead to the requirement of an increased energy-arrival rate, which is a significant parameter in energy harvesting design of a cognitive user (CU) device. A well-designed spectrum-sensing scheme will lower the energy-arrival rate that is required and enable CNs to self-sustain, which will also help alleviate global warming. In this paper, spectrum sensing in a multi-user cognitive ad hoc network with a wide-band spectrum is considered. Based on the prospective spectrum sensing, we classify CN operation into two modes: Distributed and centralized. In a distributed network, each CU conducts spectrum sensing for its own data transmission, while in a centralized network, there is only one cognitive cluster header which performs spectrum sensing and broadcasts its sensing results to other CUs. Thus, a wide-band spectrum that is divided into multiple sub-channels can be sensed simultaneously in a distributed manner or sequentially in a centralized manner. We consider the energy consumption for spectrum sensing only of an analog-to-digital convertor (ADC). By formulating energy consumption for spectrum sensing in terms of the sub-channel sampling rate and whole-band sensing time, the sampling rate and whole-band sensing time that are optimal for minimizing the total energy consumption within sensing reliability constraints are obtained. A power dissipation model of an ADC, which plays an important role in formulating the energy efficiency problem, is presented. Using AD9051 as an ADC example, our numerical results show that the optimal sensing parameters will achieve a reduction in the energy-arrival rate of up to 97.7% and 50% in a distributed and a centralized network, respectively, when comparing the optimal and worst-case energy consumption for given system settings.

에너지효율을 고려한 모델예측제어에 기초한 열펌프의 실내온도 제어 (Indoor Temperature Control of a Heat Pump Based on Model Predictive Control Considering Energy Efficiency)

  • 조항철;변경석;송재복;장효환;최영돈
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.200-208
    • /
    • 2001
  • In indoor temperature control of a heat pump, a reduction in energy consumption is very important. However, most control schemes for heat pumps have focused only on control performance such s settling time and steady-state error. In this paper, the model predictive control (MPC) which includes the energy-related variable in this cost function is proposed. By computing the control signal minimizing this cost function, the trade-off between energy reduction and temperature control performance can be obtained. Since the MPC required the process model, the dynamic mode of a heat pump is also obtained by the system identification technique. Performance of the proposed MPC considering energy efficiency is compared with the two other control schemes. It si shown that the proposed scheme can consume less energy thant hte others in achieving similar control performance.

  • PDF

식품가공공장의 에너지 절감을 위한 batch식 가열 공정 에너지 소비 분석 : 사례 연구 (Energy Consumption Analysis of Batch Type Heating Process for Energy Savings in Food Processing Plants)

  • 여채은;조우진;구재회;임채영
    • 문화기술의 융합
    • /
    • 제9권3호
    • /
    • pp.817-823
    • /
    • 2023
  • 제조 공장은 기후 변화에 따른 에너지 사용 절감 문제에 직면해 있다. 에너지 소비 절감은 생산 비용 절감 및 효율 개선과 같이 가장 중요한 문제 중 하나로 볼 수 있다. 제조 산업 군 중에서도 식품 에너지 소비 규모 증가는 식생활 수준 향상 및 인구 증가와 더불어 점차 높아지고 있다. 식품가공공장의 에너지 절감을 위해서는 에너지 다소비 공정에서의 에너지 소비 특성을 파악하고 분석하는 것이 중요하다. 이에 앞서 기존 에너지 소비량을 모니터링하고 분석하여 절감 방안을 도출하는 것이 필요하다. 본 연구에서는 육가공류를 생산하는 중소기업 규모 식품가공공장을 사례 연구로 하여 batch식 가열 공정의 주기·단계 수준에서의 에너지 소비 구조를 파악하고 분석하고자 하였다. 이를 통해 개별 공정 작업 조건에서 얻을 수 있는 현실적이고 정량적인 목표를 수립하고자 하였다. 본 연구 결과는 향후 중소기업 식품 공장 공통 핵심 공정에 대한 확산 보급형 에너지 절감 FEMS 기술 개발의 기초 자료로 활용될 것이다.

직접분사식 디젤기관에서 바이오디젤유와 함산소성분 혼합연료 적용시 배기배출물 특성 및 EGR의 적용 연구 (A Study on Emission Charncteristics and EGR Application of Blending Fuels with Biodiesel Fuel and Oxygenate Component in a D.I. Diesel Engine)

  • 최승훈;오영택
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.43-48
    • /
    • 2008
  • The exhaust emissions of diesel engine are recognized as a major cause influencing environment strongly. In this study, the possibility of biodiesel fuel and oxygenated fuel(dimethoxy methane; DMM) was investigated as an alternative fuel for a naturally aspirated direct injection diesel engine. The smoke emission of blending fuel(biodiesel fuel 90vol-%+DMM 10vol-%) was reduced approximately 70% at 2500rpm, full load, in comparison with the diesel fuel. But, power, torque and brake specific energy consumption showed no significant differences. But, NOx emission of biodiesel fuel and DMM blended fuel increased compared with commercial diesel fuel due to the oxygen component in the fuel. It was needed a NOx reduction counterplan that EGR method was used as a countermeasure for NOx reduction. It was found that simultaneous reduction of smoke and NOx emission was achieved with BDF(95 vol-%) and DMM(5 vol-%) blended fuel and cooled EGR method(15%).

Load Modeling based on System Identification with Kalman Filtering of Electrical Energy Consumption of Residential Air-Conditioning

  • Patcharaprakiti, Nopporn;Tripak, Kasem;Saelao, Jeerawan
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.45-53
    • /
    • 2015
  • This paper is proposed mathematical load modelling based on system identification approach of energy consumption of residential air conditioning. Due to air conditioning is one of the significant equipment which consumes high energy and cause the peak load of power system especially in the summer time. The demand response is one of the solutions to decrease the load consumption and cutting peak load to avoid the reservation of power supply from power plant. In order to operate this solution, mathematical modelling of air conditioning which explains the behaviour is essential tool. The four type of linear model is selected for explanation the behaviour of this system. In order to obtain model, the experimental setup are performed by collecting input and output data every minute of 9,385 BTU/h air-conditioning split type with $25^{\circ}C$ thermostat setting of one sample house. The input data are composed of solar radiation ($W/m^2$) and ambient temperature ($^{\circ}C$). The output data are power and energy consumption of air conditioning. Both data are divided into two groups follow as training data and validation data for getting the exact model. The model is also verified with the other similar type of air condition by feed solar radiation and ambient temperature input data and compare the output energy consumption data. The best model in term of accuracy and model order is output error model with 70.78% accuracy and $17^{th}$ order. The model order reduction technique is used to reduce order of model to seven order for less complexity, then Kalman filtering technique is applied for remove white Gaussian noise for improve accuracy of model to be 72.66%. The obtained model can be also used for electrical load forecasting and designs the optimal size of renewable energy such photovoltaic system for supply the air conditioning.

캐시 주소의 태그 이력을 활용한 에너지 효율적 고성능 데이터 캐시 구조 (An Energy Efficient and High Performance Data Cache Structure Utilizing Tag History of Cache Addresses)

  • 문현주;지승현
    • 정보처리학회논문지A
    • /
    • 제14A권1호
    • /
    • pp.55-62
    • /
    • 2007
  • 모바일 기기와 같이 배터리에 의존적인 시스템에서 사용되는 임베디드 프로세서는 총 소모 전력의 많은 부분을 캐시에서 소모한다. 본 논문에서는 임베디드 프로세서용 고성능 선인출 데이터캐시의 저전력화 방안을 연구하였다. 고성능 선인출 데이터캐시에서 메모리 참조명령의 수행에 앞서 참조예측의 결과로 발생하는 선인출 명령은 캐시 적중률을 높여 메모리 참조 시간을 단축하는 반면 선인출 명령의 수에 비례하여 전력 소모가 증가한다. 본 논문에서는 선인출 데이터캐시에 태그이력표(tag history table)를 구비하여 병렬태그탐색을 최소화함으로써 전력 소모를 줄이는 캐시 구조를 제안하였다. 실험을 통해 확인한 결과 제안한 데이터캐시 구조가 기존 데이터캐시 구조에 비하여 수행 시간과 전력 소모를 모두 줄일 수 있음을 확인하였다.

Development of Intelligent Electricity Saving System Using SARIMA Algorithm

  • Heo, Jun;Kim, Kyung-Shin
    • International Journal of Advanced Culture Technology
    • /
    • 제2권2호
    • /
    • pp.19-24
    • /
    • 2014
  • Many people all over the world have been conducting a great deal of research to solve the problem of global warming since the great majority consider reduction of CO2 as the only solution for that. That is why the production and conservation of energy is thought to be highly crucial. while it is important to produce energy with the high efficiency, the efficient use of the energy is also important. This paper focused on the development of devices for the reducing electricity which is a primary energy source used in homes, shops, buildings, factories and so on. Also the objective of this paper is to develop the inference mechanism as the core component of the devices. Therefore, in this paper, we propose the inference algorithm for reducing the electricity consumption using SARIMA mode and present the feasibility of the procedure.