• Title/Summary/Keyword: Energy Consumption Rate

Search Result 1,030, Processing Time 0.028 seconds

Physiological Assessment of the Psychophysical Maximum Acceptable Weight of Load for Manual Materials Handling Tasks (인력물자취급시의 인체심리학적 최대허용중량의 생리학적 고찰)

  • Jeong, Seong-Hak;Kim, Hong-Gi
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 1999
  • The objective of this study was to investigate the metabolic energy consumption rate of the psychophysical Maximum Acceptable Weight of Loads (MAWLs) for different manual materials handling tasks. Lifting activities with four different lifting frequencies (2, 5, 8, 11 lifts/min) for a lifting range (from floor to 76cm height) were studied. The oxygen consumption rate and heart rate were measured or recorded while subjects were lifting their MAWLs. It was found that the relationship between MAWL and frequency can be described best by the exponential function with the R-sq value 0.9865 for this study. Psychophysical MAWL decreased from 22.38 to 7.48 kg, while the oxygen consumption rate with the MAWL increased from 717.8 to $1114.7m{\ell}-O_2/min$ as the frequency increased from 2 to 11 lifts/min. Heart rate also increased from 104.5 to 120.7 bpm. The ratio of oxygen consumption for the MAWL to the Physical Work Capacity (PWC) ranged from 28 to 43%. The MAWLs were greater than or equal to the Maximum Permissible Limits (MPLs) when the frequencies were higher than 8 lifts/min. It seems that the MAWLs by psychophysical approach when the frequencies were higher than 8 lifts/min tend to be overestimated from the viewpoint of the physiological criterion of the oxygen consumption rates. From these findings it is suggested that the NIOSH Guideline should not be directly applied to Korean without reasonable modifications.

  • PDF

An Improved Estimation Model of Server Power Consumption for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 향상된 서버 전력 소비 추정 모델)

  • Kim, Dong-Jun;Kwak, Hu-Keun;Kwon, Hui-Ung;Kim, Young-Jong;Chung, Kyu-Sik
    • The KIPS Transactions:PartA
    • /
    • v.19A no.3
    • /
    • pp.139-146
    • /
    • 2012
  • In the server cluster environment, one of the ways saving energy is to control server's power according to traffic conditions. This is to determine the ON/OFF state of servers according to energy usage of data center and each server. To do this, we need a way to estimate each server's energy. In this paper, we use a software-based power consumption estimation model because it is more efficient than the hardware model using power meter in terms of energy and cost. The traditional software-based power consumption estimation model has a drawback in that it doesn't know well the computing status of servers because it uses only the idle status field of CPU. Therefore it doesn't estimate consumption power effectively. In this paper, we present a CPU field based power consumption estimation model to estimate more accurate than the two traditional models (CPU/Disk/Memory utilization based power consumption estimation model and CPU idle utilization based power consumption estimation model) by using the various status fields of CPU to get the CPU status of servers and the overall status of system. We performed experiments using 2 PCs and compared the power consumption estimated by the power consumption model (software) with that measured by the power meter (hardware). The experimental results show that the traditional model has about 8-15% average error rate but our proposed model has about 2% average error rate.

Comprehensive Analysis of Energy Consumption Rate and New Technology Trend in High-Performance Buildings related with Different Climatic Zones (세계 기후대별 High-Performance Buildings의 에너지 소비 원단위 평가 및 신기술 적용 동향 분석 연구)

  • Kim, Chul-Ho;Lee, Seung-Eon;Kim, Kang-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.63-72
    • /
    • 2018
  • In this study, we analyzed high-performance building technologies through a case study of 65 high-performance buildings in the U.S., Europe, Asia and Oceania. In detail, we reviewed the international trend of building energy-saving technology and energy consumption per unit area by analyzing buildings constructed within a 10 year period(2008-018). The primary energy consumption was $48-440kWh/m^2$, and the average value was calculated as $169.3kWh/m^2$. Although some buildings received high certification ratings, they did not meet either Korean or international energy evaluation standards. The system analysis revealed that many energy-saving technologies show various application rates in different countries because the technologies possess different properties. Furthermore, small-area building groups tended to have less primary energy consumption than the medium and large-area buildings, but the area-energy relationship $R^2$ value was analyzed as 0.3161, indicating no clear proportional relationship. Therefore, we propose that it is necessary to maximize the energy savings of buildings by taking into consideration a region's code, climate, building usage, area and space-using patterns to reduce energy and greenhouse gas emissions.

Potential of Agricultural Residues for Small Biomass Power Generation in Thailand

  • Panklib, Thakrit
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • The demand for energy in Thailand has been continually increasing as the economic and social country grows. Approximately 60% of Thailand's primary energy is imported, mostly petroleum products. In 2008 Thailand's total energy consumption was 80,971 ktoe and the net price of energy imported was up to 1,161 billion Baht which is equivalent to 12.8% of GDP at the current price. The energy consumption or energy demand has been growing at an annual compounded growth rate of 6.42% and the peak electric power demand and electricity consumption was recorded at 22,568 MW and 148,264 GWh and grew at a rate of 7.0% and 7.5% per annum during the period from 1989 to 2008. The gross agriculture production in 2008 was recorded at 135.4 Mt which represents agriculture residue for energy at 65.73 Mt, which is equivalent to energy potential of about 561.64 PJ or 13,292 ktoe an increase in average of 5.59% and 5.44% per year respectively. The agricultural residues can converted to 15,600 GWh/year or 1,780 MW of power capacity. So, if government sector plan to install small biomass gasification for electricity generation 200 kW for Community. The residue agricultural is available for 8,900 plants nationwide. The small biomass power generation for electricity generation not only to reduce the energy imports, it also makes the job and income for people in rural areas as well. This paper's aim is to report the energy situation in Thailand and has studied 5 main agricultural products with high residue energy potential namely sugarcane, paddy, oil palm, cassava, and maize appropriate for small electricity production. These agricultural products can be found planted in many rural areas throughout Thailand. Finally, discuss the situation, methods and policies which the government uses to promote small private power producers supplying electricity into the grid.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

Early Fuel Evaporator Effects on Cold Driveability of Automobile (조기연료 기화장치의 냉간 시동 및 주행 성능 분석)

  • 전흥신
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.178-185
    • /
    • 2002
  • The object of this paper is to investigate the effects of early fuel evaporators on cold driveability of gasoline passenger cars. Experiment has been carried out for the assessment cold start performance and cold driveability. And fuel consumption rate, emission and cylinder pressure were measured. On the base of combustion pressure of cylinder, rate of heat release, cumulative heat release amount and burned mass fraction are evaluated. The results show that fuel consumption rate is increased by 17.7%, monoxide and hydrocarbon were reduced by 23% and by 45% respectively, fluctuations of indicated mean effective pressure and maximum combustion pressure were increased by 4∼6%, fuel consumption rate per power was improved by 0.2∼2.3%. These are caused by the fact maximum heat release period and main combustion period are getting short.

An Analysis of Heating and Cooling Energy and Effect on Outdoor Air Cooling according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 및 외기냉방 효과 분석)

  • Roh, Ji-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.31-38
    • /
    • 2014
  • This study makes three apartment building complex an object of analyzing representative building types and energy consumption rate of house holds, and effect of outdoor air cooling. Recently created apatrment complex is composed of very various types of building, plan, and orientation etc. But, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively. Because architects are hard to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject is grasped, apartment building types were examined and representative types were extracted. In this study, energy simulation was conducted, and the effect to outdoor air cooling was analyzed about representative types of the subject apartment complex. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Besides solar gain, household layout of building, orientation, and plan etc. effects compositively on energy consumption rate. 2) The effect of ourdoor air cooling in building of tower type can be improved by arranging households appropriately.

Energy Consumption of Biodiesel Production Process by Supercritical and Immobilized Lipase Method (초임계와 Lipase 고정화에 의한 바이오디젤 생산 공정의 에너지소비량)

  • Min, Eung-Jae;Lee, Euy-Soo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.257-263
    • /
    • 2012
  • Biodiesel is a renewable energy which is nontoxic and acting as a replacement for conventional diesel which derived from fossil fuel. Classified biodiesel producing way such as acid, base, supercritical and enzyme methods, this study focused on eco-friendly production of biodiesel using supercritical and immobilized enzyme process. Assuming a plant with a production rate of 10,000 tons a year, a PRO II simulator program was used to simulate the product conversion rate and total energy consumption. The product conversion in supercritical process and immobilized enzyme was found to be 91.17% (including 0.9% glycerol) and 93.18% (including 1.0% glycerol) respectively. The result shows that the efficiency of immobilized enzyme process is higher compared to supercritical process but having lower end product purity. From the energy consumption point of view, supercritical process consume about 8.9 MW while immobilized enzyme process consume much lower energy which is 3.9 MW. Consequently, this study certifies that energy consumption of supercritical process is 2.3 times higher than immobilized enzyme process.

Self-Consumption Solar PV Economic Rate Analysis for RE100 Companies in Korea (한국 RE100 기업의 자가소비 태양광 발전 경제적 비율 분석)

  • Jong Yi Lee;Kyung Nam Kim
    • Current Photovoltaic Research
    • /
    • v.11 no.4
    • /
    • pp.134-143
    • /
    • 2023
  • Efforts are being made to respond to global warming. Interest in and demand for the private sector-led RE100 campaign is also increasing. Self-built solar power generation, one of the implementation tools for RE100, is not expanding. However, it can be an economical means of implementation in the long run. In this study, we intend to analyze the impact on the optimal ratio of self-solar power generation using HOMER simulation. OPR defines the optimal solar power generation ratio and looks into what changes there are in the optimal solar power ratio when self-power consumption increases and external power purchase price changes. As a result, the optimal rate of self-solar power generation has a low impact even if self-power consumption increases. As the external power unit price increases, the optimal ratio increases, and at a power unit price of 100 KRW/kWh, OPR is 24%; at 200 KRW/kWh OPR is 31%; and at 300 KRW/kWh OPR is 34%. This shows that the electricity price replaced during the life cycle has a high impact on the economic feasibility of solar power generation. However, when the external power unit price reached a certain level, the increase in OPR decreased. This shows that it is difficult for domestic companies to achieve RE100 based on the economic feasibility of solar energy alone. Therefore, efforts are needed to supply renewable energy in the public sector.