• Title/Summary/Keyword: Energy Conservation Measures

Search Result 47, Processing Time 0.024 seconds

A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis (민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출)

  • Oh, Jihyun;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

A Study on investments under capital budgeting (자본제약조건하에서의 투자시기결정에 관한 연구)

  • 정현태;성정현
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.5 no.6
    • /
    • pp.21-32
    • /
    • 1982
  • The Ministry of the Energy and Resources is planning to invest a great deal of public funds in the energy conservation measures in order to conserve the energy. This study aims at applying the project scheduling model, especially to the energy conservation measures. In the study, we develop the project scheduling model, which is based on the modified Rorie-Savage problem. And the model is applied to the X-enterprise, which is one of the leading metal industry in the nation. The result shows that the model enables the top management to choose the set of projects which promises the largest profit among the entire projects. It appears that the proposed policy of the study is more profitable than the existing policy which is namely based on the qualitative consideration.

  • PDF

Patent map development of High-efficiency electric machineries (고효율 전기기기 특허동향 분석)

  • 박종진;이창호;김남정
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2000.11a
    • /
    • pp.177-193
    • /
    • 2000
  • In foreign countries, high-efficiency electric machineries have been developed in view of cost reduction, environmental issues, energy conservation etc. Especially they focus on developing energy conservation measures and demand-side management. Thus, patent application and secure of patent claims are on the rise as important issues in this field. In this paper, we analyzed patent application trends about inverters, ac/dc converters, reactive power control equipments, high-efficiency transformers and electric ballasts among high-efficiency electric machineries. First, we analyzed general technology trends, and constructed patent technology data. Second, we graphed patent application trends in terms of application years, assignees and nations.

  • PDF

Energy Performance Evaluation of a New Commercial Building using Calibrated As-built Simulation with Monitoring Data (건물에너지 모니터링 및 시뮬레이션을 활용한 신축건물의 에너지성능평가)

  • Song, Su-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.155-166
    • /
    • 2008
  • The performance evaluation of a new building is becoming more important because efficient design alone is often not sufficient to deliver an efficient building. However, there is a lack of standard evaluation methods to measure the energy performance of a new construction that has Energy Conservation Design Measures(ECDMs). This study presents an enhanced method based on calibrated whole-building simulation for evaluating the energy performance of new commercial buildings and demonstrates its use using a case-study building, including: an Energy Use Index(EUI) comparison with sub-metered data and an evaluation of the performance of specific ECDMs. The use of this method has determined that the case-study building was shown to use approximately 47% less energy than the base-case building that has the same shape and function as the case-study building(i.e., calibrated as-built simulation mode]), but doesn't include the simulated ECDMs.

Study on Retrofit Measures for Energy Conservation in Existing Residence (기존단독주택의 에너지절약을 위한 개수방안연구)

  • Park Sang Dong;Park Hyo Sun;Yu Heon Hyeong;Min Chang Hyeon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.3
    • /
    • pp.31-51
    • /
    • 1982
  • For studying this project, we selected a 2-storied detached house as a sample which was constructed in July 1976, the last year of the 3rd 5-years economic and social development plan and also the middle year between the years of the 1st oil crisis and the 2nd oil crisis, located In Gayang-dong, Daejeon City. The contents and scope of this project was to produce retrofit measures by theoretically analyzing the building energy use between both of pre-retrofit and post-retrofit conditions of this sample house, and to compare and analyze the predicated data with experimented data under post - retrofit condition. It is suggested in this report that we have to develop rational and practical retrofit measures for energy conservations in existing residences.

  • PDF

Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West- (역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.

Level of Detail (LOD) for Building Energy Conservation Measures (ECMs) (건물 에너지 절감조치의 시뮬레이션 모델링 상세수준)

  • Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.69-80
    • /
    • 2015
  • Purpose: Since most simulation programs take the interface that lists up all the input variables representing all the functionalities, users must know where design variables of an Energy Conservation Measure (ECM) are located and also know what values are appropriate. This is why practitioner designers feel frustrated when they attempt to use simulation. The final objective of this study is to provide a building energy modeling guideline for practitioners in various fields such as architectural design and MEP. Method: As the first step of the modeling guideline, this study provides the Level of Detail (LOD) for simulation modeling of primary ECMs considering the design information available in each design phase. It is prepared by literature review, simulation functionality investigation, and field experts' survey. Result: The proposed simulation LOD offers a milestone at each design phases concerning what design variable and attributes need to be developed with how much of details in order to meet the project goal. Also each design team can set up a simulation usecase considering organizational characteristics based on the proposed LOD.

Selection of Energy Conservation Measures for Building Energy Retrofit: a Comparison between Quasi-steady State and Dynamic Simulations in the Hands of Users

  • Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.5-12
    • /
    • 2016
  • Purpose: Quasi-steady state simulations have played a pivoting role to expand the user group of simulation to design engineers and architects in Korea. Initially they are introduced in the market as a building energy performance rating tool. In domestic practice, however, quasi-steady state simulations seem to be regarded as a de facto simulation only available for energy retrofit. Selection of ECMs and economic feasibility analysis are being decided through these tools, which implies that running these tools has become a norm step of the Investment-grade Audit. Method: This study aims at identifying issues and problems with the current practice via test cases, analyzing the reasons and opportunities, and then eventually suggesting proper uses of quasi-steady state and dynamic simulations. Result: The functionality of quasi-steady state simulations is more optimized to the rating. If they are to used for energy retrofits, their off-the-shelf functions also need to be expanded for customization and detailed reports. Yet their roles may be limited only to the go/no go decision; because their algorithms are still weak at precisely estimating energy and load savings that are required for making investment decisions compared to detailed simulations.