• 제목/요약/키워드: Energy Analysis Model

검색결과 4,503건 처리시간 0.035초

온도 및 습도의 단기 예측에 있어서 역전파 알고리즘의 적용 (Application of Back-propagation Algorithm for the forecasting of Temperature and Humidity)

  • 정효준;황원태;서경석;김은한;한문희
    • 환경영향평가
    • /
    • 제12권4호
    • /
    • pp.271-279
    • /
    • 2003
  • Temperature and humidity forecasting have been performed using artificial neural networks model(ANN). We composed ANN with multi-layer perceptron which is 2 input layers, 2 hidden layers and 1 output layer. Back propagation algorithm was used to train the ANN. 6 nodes and 12 nodes in the middle layers were appropriate to the temperature model for training. And 9 nodes and 6 nodes were also appropriate to the humidity model respectively. 90% of the all data was used learning set, and the extra 10% was used to model verification. In the case of temperature, average temperature before 15 minute and humidity at present constituted input layer, and temperature at present constituted out-layer and humidity model was vice versa. The sensitivity analysis revealed that previous value data contributed to forecasting target value than the other variable. Temperature was pseudo-linearly related to the previous 15 minute average value. We confirmed that ANN with multi-layer perceptron could support pollutant dispersion model by computing meterological data at real time.

Assessment of RANS Models for 3-D Flow Analysis of SMART

  • Chun Kun Ho;Hwang Young Dong;Yoon Han Young;Kim Hee Chul;Zee Sung Quun
    • Nuclear Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.248-262
    • /
    • 2004
  • Turbulence models are separately assessed for a three dimensional thermal-hydraulic analysis of the integral reactor SMART. Seven models (mixing length, k-l, standard $k-{\epsilon},\;k-{\epsilon}-f{\mu},\;k-{\epsilon}-v2$, RRSM, and ERRSM) are investigated for flat plate channel flow, rotating channel flow, and square sectioned U-bend duct flow. The results of these models are compared to the DNS data and experiment data. The results are assessed in terms of many aspects such as economical efficiency, accuracy, theorization, and applicability. The standard $k-{\epsilon}$ model (high Reynolds model), the $k-{\epsilon}-v2$ model, and the ERRSM (low Reynolds models) are selected from the assessment results. The standard $k-{\epsilon}$ model using small grid numbers predicts the channel flow with higher accuracy in comparison with the other eddy viscosity models in the logarithmic layer. The elliptic-relaxation type models, $k-{\epsilon}-v2$, and ERRSM have the advantage of application to complex geometries and show good prediction for near wall flows.

DEVELOPMENT OF THE MATRA-LMR-FB FOR FLOW BLOCKAGE ANALYSIS IN A LMR

  • Ha, Kwi-Seok;Jeong, Hae-Yong;Chang, Won-Pyo;Kwon, Young-Min;Cho, Chung-Ho;Lee, Yong-Bum
    • Nuclear Engineering and Technology
    • /
    • 제41권6호
    • /
    • pp.797-806
    • /
    • 2009
  • The Multichannel Analyzer for Transient and steady-state in Rod Array - Liquid Metal Reactor for Flow Blockage analysis (MATRA-LMR-FB) code for the analysis of a subchannel blockage has been developed and evaluated through several experiments. The current version of the code is improved here by the implementation of a distributed resistance model which accurately considers the effect of flow resistance on wire spacers, by the addition of a turbulent mixing model, and by the application of a hybrid scheme for low flow regions. Validation calculations for the MATRA-LMR-FB code were performed for Oak Ridge National Laboratory (ORNL) 19-pin tests with wire spacers and Karlsruhe 169-pin tests with grid spacers. The analysis of the ORNL 19-pin tests conducted using the code reveals that the code has sufficient predictive accuracy, within a range of 5 $^{\circ}C$, for the experimental data with a blockage. As for the results of the analyses, the standard deviation for the Karlsruhe 169-pin tests, 0.316, was larger than the standard deviation for the ORNL 19-pin tests, 0.047.

인공지능 기반 에너지 효율화 방안 연구: 혼합적 연구방법론 중심으로 (A Study on Energy Efficiency Plan based on Artificial Intelligence: Focusing on Mixed Research Methodology)

  • 이문범;마태영
    • 한국IT서비스학회지
    • /
    • 제21권5호
    • /
    • pp.81-94
    • /
    • 2022
  • This study sets the research goal of reducing energy consumption which 'H' University Industry-University Cooperation Foundation and resident companies are concerned with, as well as conducting policy research and data analysis. We tried to present a solution to the problem using the technique. The algorithm showing the greatest reliability in the power of the model for the analysis algorithm of this paper was selected, and the power consumption trend curves per minute and hour were confirmed through predictive analysis while applying the algorithm, as well as confirming the singularity of excessive energy consumption. Through an additional sub-sensor analysis, the singularity of energy consumption of the unit was identified more precisely in the facility rather than in the building unit. Through this, this paper presents a system building model for real-time monitoring of campus power usage, and expands the data center and model for implementation. Furthermore, by presenting the possibility of expanding the field through research on the integration of mobile applications and IoT hardware, this study will provide school authorities and resident companies with specific solutions necessary to continuously solve data-based field problems.

공동주택의 건물외부조건과 에너지비용과의 관계분석 (Relation between the Building Exterior Conditions and Energy Costs in the Running period of the Apartment Housing)

  • 이강희;류승훈;이은택
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.107-113
    • /
    • 2009
  • The energy cost is resulted from the energy use. Its sources are divided into some types and depended on the building use or energy-use type. The energy cost should be affected by the amount of the energy use. The cost could be calculated to consider various factors such as the insulation, heating type, building shape and others. But it can not consider all of the affect factors to the energy cost and need to categorize the factors to the condition for estimating the cost. In this paper, it aimed at providing the estimation model in linear equation and multiple linear regression, utilizing the building exterior condition and management characteristics in apartment housing. Its survey are conducted in two parts of management characteristics and building exterior condition. The correlation analysis is conducted to get rid of the multicolinearity among the inputted factors. The number of linear equation model is 11 and includes the 1st, 2nd and 3rd equation function, power function and others. Among these, it suggested the 2nd and 3rd function and power function in terms of the statistics. In multiple linear regression model, the building volume and management area are inputted to the estimation.

건물의 냉난방 운전을 고려한 3차원 동적 지중 열교환기 열해석 모델 (Three-dimensional Equivalent Transient Ground Heat Exchanger Thermal Analysis Model by Considering Heating and Cooling Operations in Buildings)

  • 백승효
    • 토지주택연구
    • /
    • 제9권4호
    • /
    • pp.25-32
    • /
    • 2018
  • Application of geothermal energy in buildings has been gaining popularity as it provides the benefits of both heating and cooling a building. Among the various types of geothermal energy systems, ground-coupled heat pump system is the most commonly applied one in South Korea. A ground heat exchanger plays an important role as a heat source in winter and a heat sink in summer. For the stable operation of a ground-coupled heat pump system, a ground heat exchanger should be sized so that it provides sufficient heating and cooling energy. Heating and cooling energies generated in ground heat exchangers mainly depend on the temperature difference between the heating medium in ground heat exchangers and the surrounding ground. In addition, the performance of ground heat exchangers influences the change in ground temperature. Therefore, it is necessary to consider this interrelation between the change in the ground temperature and the performance of ground heat exchanger for an accurate estimation of its performance. However, previous thermal analysis models for ground heat exchangers are not competent enough to allow a complete understanding of this interrelation. Therefore, this study proposes a three-dimensional equivalent, transient ground heat exchanger analysis model. First, a previous thermal analysis model for ground heat exchangers, including an analytical model, a g-function, and a numerical model are analyzed. Next, to overcome the limitations of the previous models, a three-dimensional equivalent, transient ground heat exchanger model is proposed. Finally, this study validated the proposed model with the measurement data of the thermal response test, sandbox test, and TRNSYS DST model. All validation results showed a good agreement. These findings helped us to investigate the thermal performance of ground heat exchangers more accurately than the analytical models, and faster than the numerical models. Furthermore, the proposed model contributes to the design of ground heat exchangers by considering the different operation conditions of buildings.

수평면 전일사량 산출모델이 일사열취득계수 및 창면적비를 고려한 건물 에너지 성능분석에 미치는 영향 (Impact of Horizontal Global Solar Radiation Calculation Modelson Building Energy Performance Analysis Considering Solar Heat Gain Coefficient and Window-to-wall Ratio)

  • 김기한;오기환
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.39-47
    • /
    • 2014
  • Solar applications analysis and building energy performance depend on the quality of the solar resource data available. Unfortunately, most of the weather stations do not measure solar radiation data in Korea, as a reason many researchers have studied different solar radiation estimation models and suggested to apply them to various locations in Korea. In addition, they also studied the impact of hourly global solar radiation on energy performance of an office building by comparing the simulated building energy consumptions using four different weather files, one using measured, and three estimated solar radiation from different models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM), and concluded that there was some impact on energy performance of the building due to the using different solar radiation models. However, the result cannot be applied to all other buildings since the simulated office building for that study only used limited building characteristics such as using fixed values of solar heat gain coefficient (SHGC) and window-to-wall ratio (WWR), which are significant parameters related to solar radiation that affect to the building energy consumptions. Therefore, there is a need to identify how the building energy consumption will be changed by varying these building parameters. In this study, the impact of one measured and three estimated global solar radiation on energy performance of the office building was conducted taking account of SHGC and WWR. As a result, it was identified that the impact of four different solar radiation data on energy performance of the office building was evident regardless SHGC and WWR changes, and concluded that the most suitable solar models was changed from the CRM/ZHM to the MRM as SHGC and WWR increases.

기존 철근콘크리트 골조의 반복거동 예측을 위한 이력모델 (Hysteresis Model for the Cyclic Response of Existing Reinforced Concrete Frames)

  • 손주기;이창환
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.81-89
    • /
    • 2020
  • As the damage caused by earthquakes gradually increases, seismic retrofitting for existing public facilities has been implemented in Korea. Several types of structural analysis methods can be used to evaluate the seismic performance of structures. Among them, for nonlinear dynamic analysis, the hysteresis model must be carefully applied because it can significantly affect the behavior. In order to find a hysteresis model that predicts rational behavior, this study compared the experimental results and analysis results of the existing non-seismic reinforced concrete frames. For energy dissipation, the results were close to the experimental values in the order of Pivot, Concrete, Degrading, and Takeda models. The Concrete model underestimated the energy dissipation due to excessive pinching. In contrast, the other ones except the Pivot model showed the opposite results with relatively little pinching. In the load-displacement curves, the experimental and analysis results tended to be more similar when the column axial force was applied to columns.

Energy Storage Characteristics In Fixed Beds (Charging, Storing, Discharging)

  • Hassanein, Soubhi A.;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제29회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.17-23
    • /
    • 2004
  • In the present work, the numerical model was refined to predict the thermal analysis of energy storage in a fixed beds during (charging ,storing, discharging) mode. The governing energy equations of both fluid and the solid particles along with their initial and boundary conditions are derived using a two-phase, one dimensional model. The refined model is carried out by taking into account change of (air density , air specific heat) with air temperature and also by taking into considerations heat losses from bed to surrounding. Finite difference method was used to obtain solution of two governing energy equations of both fluid and solid particles through a computer program especially constructed for this purpose. The temperature field for the air and the solid are obtained, also efficiency of energy stored inside the bed is computed. Finally using refined model the effect of air flow rate per unit area Ga (0.2, 0.3, and 0.4 kg/$m^2$-s), and inlet air temperature (200, 250, 300 $^{\circ}C$) on energy storage characteristics was studied in three mode ( charging ,storing, discharging). The rock particles of diameter 1 em is used as bed material in this research.

  • PDF

Stability analysis of an uncooled segment of superconductor

  • Seol, S.Y.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권3호
    • /
    • pp.8-12
    • /
    • 2017
  • If the part of the HTS magnet is exposed to the outside of the cryogenic coolant due to the fluctuation of the height of the cooling liquid or the vapor generation, the uncooled part becomes very unstable. In this paper, the unstable equilibrium temperature distribution of the uncooled part of a superconductor is obtained, and the maximum temperature and energy are calculated as a function of the uncooled length. Similar to the superconductor stability problem, the current sharing model was applied to derive the theoretical formula and calculated by numerical integration. We also applied a jump model, which assumes that joule heat is generated in all of the uncooled segment, and compares it with the current sharing model results. As a result of the analysis, the stable equilibrium state and the critical uncooled length in the jump model are not shown in the current sharing model. The stability of the conductors to external disturbances was discussed based on the obtained temperature distribution, maximum temperature, and energy.