• Title/Summary/Keyword: Energy Analysis Model

Search Result 4,540, Processing Time 0.032 seconds

Dynamic Modeling of the Korean Nuclear Euel Cycle

  • Jeong, Chang-Joon;Park, Joo-Hwan;Park, Hangbok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.386-395
    • /
    • 2004
  • The Korean fuel cycle scenario has been modeled by using the dynamic analysis method. For once-through fuel cycle model, the nuclear power plant construction plan was considered, and the nuclear demand growth rate from the year 2016 was assumed to be 1%. After setup the once-thorough fuel cycle model, the DUPIC and fast reactor scenarios were modeled to investigate the environmental effect of each fuel cycle. Through the calculation of the amount of spent fuel, and the amounts of plutonium and minor actinides were estimated and compared to those of the once-through fuel cycle. The results of the once-through fuel cycle shows that the demand grows to 64 GWe and the total amount of the spent fuel would be 100 kt in the year 2100, while the total spent fuel can be reduced by 50% when the DUPIC scenario is implemented

  • PDF

An Analysis for Delaminations Using Energy Release Rate in CFRP Laminates (에너지 해방률을 이용한 CFRP 적층복합재료의 층간분리 평가)

  • Gang, Gi-Won;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.2115-2122
    • /
    • 2000
  • The understanding of impact-induced delamination is important in safety and reliability of composite structure. In this study, a model for arrest toughness is proposed in consideration of fracture behavior of composite materials. Also, the probabilistic model is proposed to describe the variability of arrest toughness due to the nonhomogeneity of material. For these models, experiments were conducted on the Carbon/Epoxy composite plates with various thickness using the impact hammer. The elastic work factor used in J-Integral is applicable to the evaluation of energy release rate. The fracture behavior can be described by crack arrest concept and the arrest toughness is independent of the delamination size. Additionally, a probabilistic characteristics of arrest toughness is well described by the Weibull distribution function. A variation of arrest toughness increases with specimen thickness.

The Analysis of Green Roof during the Summer by Numerical Method (모델을 이용한 하절기 옥상정원 해석)

  • Byun, Kihong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.51-62
    • /
    • 2016
  • The purpose of this paper is to study the effectiveness of a green roof by simple mathematical model. The developed model simulates a green roof during the summer. The results explain and support the claims in the literature such that effectiveness of a green roof depends on the climate condition, and on the insulation condition of the roof. If insolation can not be reduced more than 60% by the shading effects of a green roof, more active measures than green roof seem necessary. The analysis tools like presented in the paper is necessary especially to consider climate effect, to design, and also to test green roof.

Soil foundation effect on the vibration response of concrete foundations using mathematical model

  • Dezhkam, Behzad;Yaghfoori, Ali
    • Computers and Concrete
    • /
    • v.22 no.2
    • /
    • pp.221-225
    • /
    • 2018
  • In this paper, vibration analysis of concrete foundations resting on soil medium is studied. The soil medium is simulated by Winkler model considering spring element. The concrete foundation is modeled by thick plate elements based on classical plate theory (CPT). Utilizing energy method consists of potential energy, kinetic energy and external works in conjunction with Hamilton's principle, the motion equations are derived. Assuming the simply supported boundary condition for the concrete foundation, the Navier method is used for calculating the frequency of the structure. The effect of different parameters such as soil medium, mode numbers, length to width ratio and length to thickness ratio of the concrete foundation are shown on the frequency of the structure. At the first, the results are validated with other published works in order to show the accuracy of the obtained results. The results show that considering the soil medium, the frequency of the structure increases significantly.

A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses (공동주택용 태양열원 급탕시스템의 운전성능 연구)

  • 이윤규;황인주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

Voltage Stability Analysis Based on Energy Function Considering Tap of Transformer (변압기 탭이 반영된 에너지 함수를 이용한 전압안정도 해석)

  • Lee Ki-Je;Choi Byoung-Kon;Kwon Yong-Jun;Moon Young-Hyun;Oh Yong-Taek;Lee Byunn-Ha
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.7
    • /
    • pp.337-344
    • /
    • 2005
  • An energy function is derived on the basis of the EMM(Equivalent Mechanical Model) to take account of the effects of tap changer, and then the VC(Voltage Collapse) criteria is proposed to predict the voltage collapse in Power systems. The VC criterion can be evaluated by using the energy margin given by the energy gap between UEP(Unstable Equilibrium Point) and SEP(Stable Equilibrium Point) of the energy function adopted, in which it is noted that the energy contour should be considered due to energy discontinuity associated with tap changing. This paper shows that the proposed VC criterion improves the accuracy of voltage stability analysis with application to a two-bus sample system.

The Study of the Wind Resource and Energy Yield Assessment for the Wind Park Development (풍력자원해석 및 에너지예측을 통한 풍력발전단지 설계 연구)

  • Byun, Hyo-In;Ryu, Ji-Yune;Kim, Doo-Hoon
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.19-25
    • /
    • 2005
  • This study explains ther procedure that should be taken to develp a successful wind park project. It provides a guideline for the activities and studies to be done as a step by step solution. This study follows a chronological flow throughout the whole development Process. This Paper covers technical consideration, assessment of wind energy resource, wind Park siting and energy yield calculation This presented knowledge h3s been mostly gained by the experience from Youngduk wind park project. The further comparison study will be performed between the theoretical prediction and the actual yield of the Youngduk wind park.

  • PDF

Vibro-acoustic Analysis of Simplified Satellite Model by Using the Statistical Energy Analysis Technique (단순화된 위성체의 통계적 에너지 해석법을 이용한 음향-진동 연성 해석)

  • Jeong, Cheol-Ho;Ih, Jeong-Guon;Moon, Sang-Moo;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.711-714
    • /
    • 2002
  • At the lift-off condition, the combustion and Jet noise of launch vehicle produces a severe acoustic environment and the acoustic loads may be damaging to paylaod and equipments. Prediction of the acoustic environment is thus needed to support the load-resistive design and test-qualification of components. Currently, such a high frequency problem is usually dealt with by using the SEA technique, for which the assumptions should match reasonably well with the vibro-acoustic condition of system. The subsystems of SEA model was composed of 16 flat plates, 8 L-shaped beams, and 2 acoustic cavities. The frequency range was 400 Hz - 4 kHz considering the modal parameter. The experiment was performed in a high intensity acoustic chamber, in which the diffuse acoustic field was assured. By comparing the SEA analysis and the experiments, the error less than 5 dB was observed.

  • PDF

Development of the Contingency Analysis Program of Korean Energy Management System (한국형 에너지 관리시스템용 상정고장 해석프로그램 개발)

  • Cho, Yoon-Sung;Yun, Sang-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.232-241
    • /
    • 2010
  • This paper describes the development of robust contingency analysis program for Korean Energy Management System. The important function of contingency analysis is to determine the bus/branch model for contingency, and to calculate the state of the power network based on the network model and topology output. In the proposed method, the bus/branch models for contingencies are determined exactly using a fast linked-list method based on the application common model database. To calculate the state of the power system included contingency, the full-decoupled powerflow approach, the partial powerflow method for contingencies and the proposed contingency screening algorithm are also used to contingency analysis. To verify the performance of the developed processor, we performed a file-based test using several structured input data and online test using the database which resides on memory. The results of these comprehensive tests showed that the developed processors can accurately calculate the power system contingency state from online data and can be applied to Korea Power Exchange system.

Pseudo seismic and static stability analysis of the Torul Dam

  • Karabulut, Muhammet;Genis, Melih
    • Geomechanics and Engineering
    • /
    • v.17 no.2
    • /
    • pp.207-214
    • /
    • 2019
  • Dams have a great importance on energy and irrigation. Dams must be evaluated statically and dynamically even after construction. For this purpose, Torul dam built between years 2000 and 2007 Harsit River in Gümüşhane province, Turkey, is selected as an application. The Torul dam has 137 m height and 322 GWh annual energy production capacity. Torul dam is a kind of concrete face rock fill dam (CFRD). In this study, static and pseudo seismic stability of Torul dam was investigated using finite element method. Torul dam model is constituted by numerical stress analysis named Phase2 which is based on finite element method. The dam was examined under 11 different water filling levels. Thirteenth stage of the numerical model is corresponding full reservoir condition which water filled up under crest line. Besides, pseudo static coefficients for dynamic condition applied to the dam in fourteenth stage of the model. Stability assessment of the Torul dam has been discussed according to the displacement throughout the dam body. For static and pseudo seismic cases, the displacements in the dam body have been compared. The total displacements of the dam according to its the empty state increase dramatically at the height of the water level of about 70 m and above. Compared to the pseudo-seismic analysis, the displacement of dam at the full reservoir condition is approximately two times as high as static analysis.