• Title/Summary/Keyword: Energy Analysis Model

Search Result 4,522, Processing Time 0.038 seconds

Thermal-hydraulic research on rod bundle in the LBE fast reactor with grid spacer

  • Liu, Jie;Song, Ping;Zhang, Dalin;Wang, Shibao;Lin, Chao;Liu, Yapeng;Zhou, Lei;Wang, Chenglong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2728-2735
    • /
    • 2022
  • The research on the flow and heat transfer characteristics of lead bismuth(LBE) is significant for the thermal-hydraulic calculation, safety analysis and practical application of lead-based fast reactors(LFR). In this paper, a new CFD model is proposed to solve the thermal-hydraulic analysis of LBE. The model includes two parts: turbulent model and turbulent Prandtl, which are the important factors for LBE. In order to find the best model, the experiment data and design of 19-pin hexagonal rod bundle with spacer grid, undertaken at the Karlsruhe Liquid Metal Laboratory (KALLA) are used for CFD calculation. Furthermore, the turbulent model includes SST k - 𝜔 and k - 𝜀; the turbulent Prandtl includes Cheng-Tak and constant (Prt =1.5,2.0,2.5,3.0). Among them, the combination between SST k - 𝜔 and Cheng-Tak is more suitable for the experiment. But in the low Pe region, the deviation between the experiment data and CFD result is too much. The reason may be the inlet-effect and when Pe is in a low level, the number of molecular thermal diffusion occupies an absolute advantage, and the buoyancy will enhance. In order to test and verify versatility of the model, the NCCL performed by the Nuclear Thermal-hydraulic Laboratory (Nuthel) of Xi'an Jiao tong University is used for CFD to calculate. This paper provides two verification examples for the new universal model.

A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety (건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

Prediction of Mechanical Behavior for Carbon Black Added Natural Rubber Using Hyperelastic Constitutive Model

  • Kim, Beomkeun
    • Elastomers and Composites
    • /
    • v.51 no.4
    • /
    • pp.308-316
    • /
    • 2016
  • The rubber materials are widely used in automobile industry due to their capability of a large amount of elastic deformation under a force. Current trend of design process requires prediction of functional properties of parts at early stage. The behavior of rubber material can be modeled using strain energy density function. In this study, five different strain energy density functions - Neo-Hookean model, Reduced Polynomial $2^{nd}$ model, Ogden $3^{rd}$ model, Arruda Boyce model and Van der Waals model - were used to estimate the behavior of carbon black added natural rubber under uniaxial load. Two kinds of tests - uniaxial tension test and biaxial tension test - were performed and used to correlate the coefficients of the strain energy density function. Numerical simulations were carried out using finite element analysis and compared with experimental results. Simulation revealed that Ogden $3^{rd}$ model predicted the behavior of carbon added natural rubber under uniaxial load regardless of experimental data selection for coefficient correlation. However, Reduced Polynomial $2^{nd}$, Ogden $3^{rd}$, and Van der Waals with uniaxial tension test and biaxial tension test data selected for coefficient correlation showed close estimation of behavior of biaxial tension test. Reduced Polynomial $2^{nd}$ model predicted the behavior of biaxial tension test most closely.

Feasibility Analysis of Alternative Electricity Systems by 2030 in the Post-Fukushima Era

  • Park, Nyun-Bae;Lee, Sanghoon;Han, Jin-Yi;Jeon, Eui Chan
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • The Fukushima nuclear accident in 2011 had an extensive impact on the national electricity plans. This paper outlines alternative electricity scenarios that meet the goals of nuclear phase-out and greenhouse gas (GHG) emission reduction. This paper also analyzes the results of each scenario in respect to the electricity mix, GHG emissions, costs and employment effects. The Long-range Energy Alternatives Planning system (LEAP) model was used to simulate the annual electricity demand and supply system from 2011 to 2030. The reference year was 2009. Scenarios are reference (where existing plans are continued), A1, A2, B1, B2, and C2 (where the levels of demand management and nuclear phase-out are different). The share of renewable energy in the electricity mix in 2030 for each scenario will be increased from about 1% in 2009 to 8% in the reference scenario and from 11% to 31% in five alternative scenarios. Total cumulative cost increases up to 14% more than the reference scenario by replacing nuclear power plants with renewable energy in alternative scenarios could be affordable. Deploying enough renewable energy to meet such targets requires a roadmap for electricity price realization, expansion of research, development and deployment for renewable energy technologies, establishment of an organization dedicated to renewable energy, and ambitious targets for renewable energy.

Aerodynamic Characteristic Analysis of the Darrieus Turbine Using Double Multiple Streamtube Model (이중 다류관 모델을 이용한 Darrieus 터어빈의 공기역학적 특성 해석)

  • Kim, Keon-Hoon;Park, Kyung-Ho;Chung, Hun-Saeng
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.47-56
    • /
    • 1990
  • The aerodynamic performances of Darrieus wind turbine were studied through the wind tunnel model tests and its analytical aerodynamic streamtube model. Hence, analytical streamtube model which is based on momentum and blade element theory is considered and the formulated model was generalized in non-dimensional type to predict the aerodynamic characteristics of Darrieus wind turbine. The analytical model was justified through the wind tunnel model tests for several experimental conditions but in the limited rages. These satisfactory comparative studies between the wind tunnel tests and the analytical predictions can be utilized for the basic reliable design of Darrieus wind turbine.

  • PDF

Optimal Life Cycle design of Water Pipe System using Genetic Algorithm (상수관망 최적 생애주기 설계를 위한 유전알고리즘의 적용)

  • Lee, Seungyub;Yoo, Do Guen;Jung, Donghwi;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4216-4227
    • /
    • 2015
  • In this study, a model is developed based on Life Cycle Energy Analysis (LCEA) method with Genetic Algorithm (GA) to determine optimal diameter of Water Distribution System (WDS). For hydraulic analysis the EPANET2.0 program is linked with developed model, pipe-aging equation and pipe-breakage equation are built in to developed model to simulate pipe change through life cycle. The model is then applied to two sample WDSs for optimal energy design. After determining optimal diameter for each WDS, the total cost is calculated based on determined diameter and compared with well-known optimal diameter set of each WDS. Results show that optimal energy design of WDSs through the developed model can be an alternative option for optimal design of WDSs for reducing energy with lower in cost.

Analysis of Dynamics Characteristics of Water Injection Pump through the 2D Finite Element (2D 유한요소 해석을 통한 물 분사 펌프의 동특성 분석)

  • Lee, Jong-Myeong;Kim, Yong-Hwi;Kim, Jun-Ho;Choi, Hyeon-Cheol;Choi, Byeong Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.462-469
    • /
    • 2014
  • After drilling operations at the offshore plant, crude oil is producted under high pressure. After that time, oil recovery is reduced, because the pressure of the pipe inside is low during the secondary produce. At that time injection sea water at the pipe inside through water injection pump that the device increase to recovery. A variety of mathematical analysis during the detailed design analysis was not made through the dynamics characteristic at the domestic company. 2D model has reliability of analysis results for the uncomplicated model. Also element and the node the number of significantly less than in the 3D model. So, the temporal part is very effective. In addition, depending on the quality of mesh 3D is a real model and FEM model occurs error. So, user needs a lot of skill. In this paper, a 2D finite element analysis was performed through the dynamics analysis and the study model was validated.

Analysis of Very High Resolution Solar Energy Based on Solar-Meteorological Resources Map with 1km Spatial Resolution (1km 해상도 태양-기상자원지도 기반의 초고해상도 태양 에너지 분석)

  • Jee, JoonBum;Zo, Ilsung;Lee, Chaeyon;Choi, Youngjean;Kim, Kyurang;Lee, KyuTae
    • New & Renewable Energy
    • /
    • v.9 no.2
    • /
    • pp.15-22
    • /
    • 2013
  • The solar energy are an infinite source of energy and a clean energy without secondary pollution. The global solar energy reaching the earth's surface can be calculated easily according to the change of latitude, altitude, and sloped surface depending on the amount of the actual state of the atmosphere and clouds. The high-resolution solar-meteorological resource map with 1km resolution was developed in 2011 based on GWNU (Gangneung-Wonju National University) solar radiation model with complex terrain. The very high resolution solar energy map can be calculated and analyzed in Seoul and Eunpyung with topological effect using by 1km solar-meteorological resources map, respectively. Seoul DEM (Digital Elevation Model) have 10m resolution from NGII (National Geographic Information Institute) and Eunpyeong new town DSM (Digital Surface Model) have 1m spatial resolution from lidar observations. The solar energy have small differences according to the local mountainous terrain and residential area. The maximum bias have up to 20% and 16% in Seoul and Eunpyung new town, respectively. Small differences are that limited area with resolutions. As a result, the solar energy can calculate precisely using solar radiation model with topological effect by digital elevation data and its results can be used as the basis data for the photovoltaic and solar thermal generation.

Microgrid energy scheduling with demand response

  • Azimian, Mahdi;Amir, Vahid;Haddadipour, Shapour
    • Advances in Energy Research
    • /
    • v.7 no.2
    • /
    • pp.85-100
    • /
    • 2020
  • Distributed energy resources (DERs) are essential for coping with growing multiple energy demands. A microgrid (MG) is a small-scale version of the power system which makes possible the integration of DERs as well as achieving maximum demand-side management utilization. Hence, this study focuses on the analysis of optimal power dispatch considering economic aspects in a multi-carrier microgrid (MCMG) with price-responsive loads. This paper proposes a novel time-based demand-side management in order to reshape the load curve, as well as preventing the excessive use of energy in peak hours. In conventional studies, energy consumption is optimized from the perspective of each infrastructure user without considering the interactions. Here, the interaction of energy system infrastructures is considered in the presence of energy storage systems (ESSs), small-scale energy resources (SSERs), and responsive loads. Simulations are performed using GAMS (General Algebraic modeling system) to model MCMG, which are connected to the electricity, natural gas, and district heat networks for supplying multiple energy demands. Results show that the simultaneous operation of various energy carriers, as well as utilization of price-responsive loads, lead to better MCMG performance and decrease operating costs for smart distribution grids. This model is examined on a typical MCMG, and the effectiveness of the proposed model is proven.

DECADES database implementation and application for the enhanced electricity system analysis methodology in the restructured electricity industry (전력 구조 개편에 따른 환경 영향 평가 및 경제적 분석을 위한 DECADES 데이터 베이스 구축 및 활용)

  • Oh, Young-Jin;Noh, Jae-Hyung;Kim, Bal-Ho;Chun, Yeong-Han;Park, Jong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.386-388
    • /
    • 2002
  • The key objectives of this study are to develop the enhanced electricity system analysis methodologies and decision making process applicable to the analysis of the energy policies, especially the renewable energy policy, through surveying the recent trend and relevant study results. This study utilizes DECADES model, a comparative assessment tool developed by IAEA, and suggests a way to establish DECADES database required to make it applicable to Korean electricity system analysis. For this, a survey on the existing database of various organizations is performed. A case study on the economic and environmental impact of renewable energy is made using DECADES model.

  • PDF