• Title/Summary/Keyword: Endovascular technique

Search Result 65, Processing Time 0.021 seconds

PDA Clipping by Using 2mm Thoracoscope (2 mm 흉강경을 이용한 동맥관 개존증 폐쇄술 -1례보고-)

  • Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.85-87
    • /
    • 2000
  • Patent ductus arteriosus(PDA) is a common congenital heart disease encountered in premature neonates infants and children. Patent ductus arteriosus was the first surgically managed congenital heart disease,. Classic surgical interruption of patent ducturs arteriosus was partially replaced by a transcatheter endovascular closure, After a 5-7 mm video-assisted thoracoscopic interruption of the patent ductus arteriosus first applied in 1991, this minimally invasive technique came to be used in many centers, Video-assisted thoracoscopic interruption of the patent ductus arteriosus is feasible in low-weight infants whereas transcatheter endovascular closure of the ductus is usually not possible. We experienced successful outcome for the treatment of patent ductus arteriosus with 2 mm video-assisted thoracoscopic titanium clipping, We believed that this technique is a simple safe and rapid method for closure of the patent arteriosus.

  • PDF

Long-Term Outcomes of Placement of a Single Transverse Stent through the Anterior Communicating Artery via the Nondominant A1 in Coil Embolization of Wide-Necked Anterior Communicating Artery Aneurysms

  • Ban, Seung Pil;Kwon, O-Ki;Kim, Young Deok
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.40-48
    • /
    • 2022
  • Objective : Placement of a single transverse stent via the nondominant A1 across the anterior communicating artery (AComA) into the contralateral A2 can provide sufficient neck coverage for wide-necked bifurcation AComA aneurysms. The authors described the feasibility, safety and long-term outcomes of this technique. Methods : Between January 2015 and February 2018, placement of a single transverse stent via the nondominant A1 was attempted in 17 wide-necked bifurcation AComA aneurysms. The authors reviewed the medical records and radiological studies. Results : The technical success rate was 94.1% (16/17). Periprocedural thromboembolic complications occurred in one patient (6.3%) without permanent neurological deficits. The mean clinical follow-up duration was 39.9±9.8 months. No deaths or delayed thromboembolic complications occurred. The mean angiographic follow-up duration was 38.9±9.8 months. The immediate and final follow-up complete occlusion rates were 87.4 and 93.7%, respectively. There was no recanalization during the follow-up period. Conclusion : Placement of a single transverse stent via the nondominant A1 across the AComA into the contralateral A2 is a feasible and relatively safe endovascular technique for the treatment of wide-necked bifurcation AComA aneurysms, with good long-term occlusion rates and a reasonable complication rate, if only the nondominant A1 is applicable.

Merit of Zone III Resuscitative Endovascular Occlusion of the Aorta under Real-Time Fluoroscopy in Hybrid ER: A Case of REBOA in Traumatic Cardiac Arrest

  • Lee, Sung Do;Chung, Seungwoo;Ki, Young Jun;Seo, Sang Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • v.33 no.3
    • /
    • pp.191-194
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a novel technique to maintain proximal arterial pressure. It is important to locate the balloon catheter correctly in performing REBOA but it is inaccurate to check the catheter position by external measurement. Even if the position of the catheter is initially confirmed by X-ray, it is difficult to determine the location of the catheter that changes according to various situations. We performed REBOA under real-time fluoroscopy and could maintain the catheter in correct position under various situations.

Extensive Inferior Vena Cava Injury Following Blunt Abdominal Trauma: A Case Report (복부 둔상 후에 발생한 광범위한 하대정맥 손상: 증례보고)

  • Yoo, Young Sun;Mun, Seong Pyo
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.219-223
    • /
    • 2014
  • Traumatic injuries of the inferior vena cava (IVC) are the most challenging lesions in abdominal vascular injuries and are associated with a high mortality rate. Although endovascular treatment has been addressed in the management of vascular trauma, surgery is the mainstay in the treatment for IVC injury as an endovascular technique for the venous system has not been developed. We report a case of successful surgical repair of an extensive IVC laceration following a fall.

Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

  • Cho, Young Dae;Rhim, Jong Kook;Yoo, Dong Hyun;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.262-268
    • /
    • 2017
  • Objective : Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods : To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results : This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion : Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites.

The $Outback^{(R)}$ $LTD^{TM}$ Catheter: The Novel Re-Entry Technique in Recanalization of Chronic Inflow Occlusion of the Superficial Femoral Arteries in 3 Cases ($Outback^{(R)}$ $LTD^{TM}$ Catheter를 이용한 표재성 대퇴동맥의 만성동맥폐색증의 성공적인 재개통술: 3예 보고)

  • Kong, Joon-Hyuk;Hur, Jin;Kim, Duk-Sil;Kim, Sung-Wan
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.785-789
    • /
    • 2010
  • The acute technical failure of endovascular treatment of chronic total occlusions is most often due to the inability to re-enter the true lumen after occlusion is crossed in a subintimal plane. True lumen re-entry catheters are very effective at gaining wire passage back to the true lumen and facilitating successful endovascular treatment of chronic total occlusions that would otherwise require open bypass. These case reports describe our initial experiences with a new catheter system (the $Outback^{(R)}$ $LTD^{TM}$ catheter) that is designed to allow fluoroscopically controlled re-entry of the true arterial lumen after subintimal guidewire passage during recanalization procedures of arterial occlusions.

Endovascular Treatment of Cerebral Aneurysms: Technical Options in Coil Embolization (뇌동맥류의 혈관 내 치료: 코일색전술의 기술적 선택)

  • Moon Hee Han
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.549-561
    • /
    • 2020
  • Since the endosaccular coil embolization technique was introduced as an alternative for treating selected patients with aneurysms, it has become a mainstay of treatment for cerebral aneurysms. In lesions with a neck larger than the aneurysmal body, an irregular shape, or arterial branches incorporated within the sac, endovascular treatment using detachable coils are traditionally contraindicated because of technical difficulties. Coil embolization has evolved as a result of both the development of related devices and the introduction of technical improvements using various devices. Use of various technical and device options can make endovascular treatment of cerebral aneurysms safer and can widen the treatment indications. Various technical options, including the technical modification of device-assisted techniques, will be presented, and the related practical points will be discussed in this issue.

General Considerations of Ruptured Abdominal Aortic Aneurysm: Ruptured Abdominal Aortic Aneurysm

  • Lee, Chung Won;Bae, Miju;Chung, Sung Woon
    • Journal of Chest Surgery
    • /
    • v.48 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Although development of surgical technique and critical care, ruptured abdominal aortic aneurysm still carries a high mortality. In order to obtain good results, various efforts have been attempted. This paper reviews initial management of ruptured abdominal aortic aneurysm and discuss the key point open surgical repair and endovascular aneurysm repair.

Bilateral Vertebral Artery Dissecting Aneurysms Presenting with Subarachnoid Hemorrhage Treated by Staged Coil Trapping and Covered Stents Graft

  • Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.155-159
    • /
    • 2012
  • The treatment of bilateral vertebral artery dissecting aneurysms (VADAs) presenting with subarachnoid hemorrhage (SAH) is still challenging. The authors report a rare case of bilateral VADA treated with coil trapping of ruptured VADA and covered stents implantation after multiple unsuccessful stent assisted coiling of the contralateral unruptured VADA. A 44-year-old woman was admitted to our hospital because of severe headache and sudden stuporous consciousness. Brain CT showed thick SAH and intraventricular hemorrhage. Cerebral angiography demonstrated bilateral VADA. Based on the SAH pattern and aneurysm configurations, the right VADA was considered ruptured. This was trapped with endovascular coils without difficulty. One month later, the contralateral unruptured VADA was protected using a stent-within-a-stent technique, but marked enlargement of the left VADA was detected by 8-months follow-up angiography. Subsequently two times coil packing for pseudosacs resulted in near complete occlusion of left VADA. However, it continued to grow. Covered stents graft below the posterior inferior cerebellar artery (PICA) origin and a coronary stent implantation across the origin of the PICA resulted in near complete obliteration of the VADA. Covered stent graft can be used as a last therapeutic option for the management of VADA, which requires absolute preservation of VA flow.

Y-Stenting Endovascular Treatment for Ruptured Intracranial Aneurysms : A Single-Institution Experience in Korea

  • Lee, Woo Joo;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.187-192
    • /
    • 2012
  • Objective : Stent-assisted coiling on intracranial aneurysm has been considered as an effective technique and has made the complex aneurysms amenable to coiling. To achieve reconstruction of intracranial vessels with preservation of parent artery the use of stents has the greatest potential for assisted coiling. We report the results of our experiences in ruptured wide-necked intracranial aneurysms using Y-stent coiling. Methods : From October 2003 to October 2011, 12 patients (3 men, 9 women; mean age, 62.6) harboring 12 complex ruptured aneurysms (3 middle cerebral artery, 9 basilar tip) were treated by Y-stent coiling by using self-expandable intracranial stents. Procedural complications, clinical outcome, and initial and midterm angiographic results were evaluated. The definition of broad-necked aneurysm is neck diameter over than 4 mm or an aneurysm with a neck diameter smaller than 4 mm in which the dome/neck ratio was less than 2. Results : In all patients, the aneurysm was successfully occluded with no apparent procedure-related complication. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. Follow-up studies showed stable and complete occlusion of the aneurysm in all patients with no neurologic deficits. Conclusion : The present study did show that the Y-stent coiling seemed to facilitate endovascular treatment of ruptured wide-necked intracranial aneurysms. More clinical data with longer follow-up are needed to establish the role of Y-stent coiling in ruptured aneurysms.