• Title/Summary/Keyword: Endovascular, stent

Search Result 163, Processing Time 0.026 seconds

Two-Stage Endovascular Repair for Concurrent Penetrating Atherosclerotic Ulcers of the Thoracic and Abdominal Aorta

  • Kong, Joon Hyuk;Baek, Kang Seok;Kwun, Woo Hyung;Kim, Young Hwan;Kim, Duk-Sil;Kim, Sung-Wan
    • Journal of Chest Surgery
    • /
    • v.46 no.5
    • /
    • pp.365-368
    • /
    • 2013
  • We report a case of concurrent saccular aneurysms caused by a penetrating atherosclerotic ulcer of the thoracic and abdominal aorta that were successfully treated by staged endovascular repair. Even though surgical open repair or endovascular repair is the treatment option, use of endovascular repair is now accepted as an alternative treatment to surgery in selected patients. To prevent contrast medium-induced nephropathy and spinal cord ischemia caused by a simultaneous endovascular procedure, a saccular aneurysm of the descending thoracic aorta was excluded by stent graft, followed by the placement of a bifurcated stent graft in the infrarenal abdominal aorta one month later.

Endovascular Treatment for Vascular Injuries of the Extremities (사지 혈관 손상의 인터벤션 치료)

  • Tae Won Choi;Yohan Kwon;Jinoo Kim;Je Hwan Won
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.846-854
    • /
    • 2023
  • Vascular injuries of the extremities are associated with a high mortality rate. Conventionally, open surgery is the treatment of choice for peripheral vascular injuries. However, rapid development of devices and techniques in recent years has significantly increased the utilization and clinical application of endovascular treatment. Endovascular options for peripheral vascular injuries include stent-graft placement and embolization. The surgical approach is difficult in cases of axillo-subclavian or iliac artery injuries, and stent-graft placement is a widely accepted alternative to open surgery. Embolization can be considered for arterial injuries associated with active bleeding, pseudoaneurysms, and arteriovenous fistula and in patients in whom embolization can be safely performed without a risk of ischemic complications in the extremities. Endovascular treatment is a minimally invasive procedure and is useful as a simultaneous diagnostic and therapeutic approach, which serve as advantages of this technique that is widely utilized for vascular injuries of the extremities.

Y-Stenting Endovascular Treatment for Ruptured Intracranial Aneurysms : A Single-Institution Experience in Korea

  • Lee, Woo Joo;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.187-192
    • /
    • 2012
  • Objective : Stent-assisted coiling on intracranial aneurysm has been considered as an effective technique and has made the complex aneurysms amenable to coiling. To achieve reconstruction of intracranial vessels with preservation of parent artery the use of stents has the greatest potential for assisted coiling. We report the results of our experiences in ruptured wide-necked intracranial aneurysms using Y-stent coiling. Methods : From October 2003 to October 2011, 12 patients (3 men, 9 women; mean age, 62.6) harboring 12 complex ruptured aneurysms (3 middle cerebral artery, 9 basilar tip) were treated by Y-stent coiling by using self-expandable intracranial stents. Procedural complications, clinical outcome, and initial and midterm angiographic results were evaluated. The definition of broad-necked aneurysm is neck diameter over than 4 mm or an aneurysm with a neck diameter smaller than 4 mm in which the dome/neck ratio was less than 2. Results : In all patients, the aneurysm was successfully occluded with no apparent procedure-related complication. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. Follow-up studies showed stable and complete occlusion of the aneurysm in all patients with no neurologic deficits. Conclusion : The present study did show that the Y-stent coiling seemed to facilitate endovascular treatment of ruptured wide-necked intracranial aneurysms. More clinical data with longer follow-up are needed to establish the role of Y-stent coiling in ruptured aneurysms.

Clinical and Angiographic Outcomes of Endovascular Treatment for Acute Intracranial Vertebral Artery Dissecting Aneurysms Using Double-Overlapping Stents : Low-Profile Visualized Intraluminal Support within Enterprise Stents

  • Ja Ho Koo;Eui Hyun Hwang;Ji Hye Song;Yong Cheol Lim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.5
    • /
    • pp.531-540
    • /
    • 2024
  • Objective : The use of reconstructive treatment with a double-overlapping stents has proven to be effective and safe in the current treatment of intracranial vertebral artery dissecting aneurysms (VADAs). We employed a combination of overlapping stents, using low-profile visualized intraluminal support (LVIS) within the Enterprise stent. This combination was chosen to minimize the outward bulging of the inner LVIS by overlapping it with the Enterprise stent while maintaining flow diversion and stability. This study aimed to evaluate the clinical and angiographic outcomes following the use of double-overlapping stents with LVIS within the Enterprise stent for the treatment of VADAs. Methods : From March 2016 to January 2022, total 28 patients with unruptured VADAs were treated with the double-overlapping stent technique using LVIS within an Enterprise stent in our institute. The Enterprise stent was deployed first, followed by the LVIS stent. Patient clinical and angiographic characteristics, procedural complications, and follow-up outcomes were retrospectively reviewed. Results : All 28 patients (18 males and 10 females) were successfully treated with double-overlapping stent deployment. There were no procedural complications or new neurological deficits in any patient. Of the 28 patients, four VADAs had posterior inferior cerebellar artery involvement. Procedure-related parent artery occlusion did not occur during the angiographic follow-up conducted 6 to 12 months after the procedure. Out of 28 patients, 24 showed complete healing, three had focal residual stenosis or dilatation with residual sac and only one had a residual dissecting flap with aneurysm. All patients, including the four patients, did not require any additional procedures. The postoperative modified Rankin scale scores were 0-1 for all patients. Conclusion : A double-overlapping stent, with a flow-diversion effect, is a safe and effective treatment for patients with VADAs. In particular, when using the LVIS stent within an Enterprise stent, it minimizes the bulging of the inner LVIS stent while maintaining flow diversion and stability. Therefore, both can be effectively utilized as overlapping stents.

Endovascular Stent Placement in a Patient with a Posttraumatic Isolated Superior Mesenteric Artery Dissection with Focally Progressing Dissecting Aneurysms and a Severely Compressed True Lumen (외상 후 단독 상장간막동맥박리 후에 국소적으로 진행된 박리성 동맥류와 심한 진강의 압박이 있는 환자에서 혈관내 스텐트설치술 1례)

  • Kim, Young-Kyu;Her, Kyu Hee;Kim, Seung Hyoung;Kim, Kwangsik
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.266-271
    • /
    • 2015
  • Reports on a posttraumatic isolated superior mesenteric artery (SMA) dissection are rare. Recently, endovascular stent placement via percutaneous access, instead of vascular surgery, has been widely accepted as the initial treatment for a patient with an isolated SMA dissection or its complications. A 60-year-old female patient was transferred to our hospital due to an isolated SMA dissection after a car accident. The SMA dissection was 8.5 cm in length, and it involved the true lumen, which was severely compressed by the thrombosed false lumen. The patient was closely observed because she did not complain of any specific visceral pain. On the seventh hospital day, she underwent computed tomography (CT) to decide on a further treatment plan, irrespective of the presence of the abdominal symptom. The findings of the follow-up CT showed no difference compared to those of the previous CT. She was discharged with anti-coagulants. One month later, the follow-up CT revealed focally progressing dissecting aneurysms in the false lumen of the dissected SMA and a more severely compressed true lumen. Two self-expandable metallic stents were successfully placed in the true lumen of the dissected SMA, covering two aneurysmal lesions. Herein, we report a successful endovascular treatment with stent placement for treating focally progressing dissecting aneurysms and a severely compressed true lumen in a patient with a posttraumatic isolated SMA dissection.

  • PDF

Treating a Ruptured Ascending Aorta with an Endovascular Stent Graft (상행 대동맥 파열에서 혈관내 스텐트 그라프트를 이용한 치료)

  • Kim, Gwan-Sic;Lee, Taek-Yeon;Kim, Joon-Bum;Lee, Seung-Hyun;Kim, Hee-Jung;Cho, Won-Chul
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.92-95
    • /
    • 2010
  • Endovascular stent grafting is regarded as a promising alternative approach to open surgical repair for treating various aortic diseases in high risk patients. We report here on a case of a 79-year-old female who underwent endovascular stent-graft insertion in the ascending aorta for treating a complicated ascending aortic rupture that occurred secondary to radiation necrosis during the treatment of recurrent breast cancer.

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

  • Li, Xue-dong;Qin, Jun;Xiao, Zhen-yong;Feng, Yi;Chen, Jia-kang
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.341-345
    • /
    • 2016
  • Objective : Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. Methods : Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center in China. Technical and clinical complications were recorded. Modified Rankin Scale was used to evaluate the patients' conditions via clinic and telephone follow-up. Results : The mean width of aneurysm sac was $2.30{\pm}0.42mm$, and the mean diameter of aneurysm neck was $2.83{\pm}.48mm$. Complete occlusion was achieved in 28 aneurysms (90.32%); neck remnant was seen in 3 aneurysms (9.68%). Technical and clinical complications related to the procedure were encountered in four patients (12.5%). Two patients died (6.25%). No patient had a permanent deficit. Conclusion : Solitaire AB stent was a safe and efficiency tool in assisting coiling of micro aneurysms with wide neck, but may be not suitable for a blaster-like one. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

Flow diversion of a middle cerebral artery pseudoaneurysm secondary to a gunshot wound: A case report

  • Justin C. Gelman;Max Shutran;Michael Young;Philipp Taussky;Rafael A. Vega;Rocco Armonda;Christopher S. Ogilvy
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.434-439
    • /
    • 2023
  • Pseudoaneurysms are rare but devastating complications of penetrating head traumas. They require rapid surgical or endovascular intervention due to their high risk of rupture; however, complex presentations may limit treatment options. Our objective is to report a case of severe vasospasm, flow diversion, and in-stent stenosis complicating the treatment of a middle cerebral artery pseudoaneurysm following a gunshot wound. A 33-year-old woman presented with multiple calvarial and bullet fragments within the right frontotemporal lobes and a large right frontotemporal intraparenchymal hemorrhage with significant cerebral edema. She underwent an emergent right hemicraniectomy for decompression, removal of bullet fragments, and evacuation of hemorrhage. Once stable enough for diagnostic cerebral angiography, she was found to have an M1 pseudoaneurysm with severe vasospasm that precluded endovascular treatment until the vasospasm resolved. The pseudoaneurysm was treated with flow diversion and in-stent stenosis was found at 4-month follow-up angiography that resolved by 8 months post-embolization. We report the successful flow diversion of an middle cerebral artery (MCA) pseudoaneurysm complicated by severe vasospasm and later in-stent stenosis. The presence of asymptomatic stenosis is believed to be reversible intimal hyperplasia and a normal aspect of endothelial healing. We suggest careful observation and dual-antiplatelet therapy as a justified approach.

Thoracic Endovascular Repair for Complicated Type B Acute Aortic Dissection with Distal Malperfusion

  • Choo, Suk-Jung;Jung, Sung-Ho;Kim, Ji-Eon;Lim, Ju-Yong;Ju, Min-Ho
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.427-431
    • /
    • 2011
  • Successful thoracic endovascular repair for complicated Stanford type B acute aortic dissection in two patients is herein reported. The true lumen flow was immediately restored following stent graft deployment in the descending thoracic aorta with subsequent resolution of the distal malperfusion syndrome. One patient is doing well more than 15 months after surgery and another patient who was treated more recently is also doing well 7 months postoperatively.

Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

  • Lee, Youngok;Kim, Gun-Jik;Kim, Young Eun;Hong, Seong Wook;Lee, Jong Tae
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.465-467
    • /
    • 2016
  • The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.