• Title/Summary/Keyword: Endovascular, stent

Search Result 163, Processing Time 0.028 seconds

In-Stent Stenosis of Stent Assisted Endovascular Treatment on Intracranial Complex Aneurysms

  • Yoon, Kyeong-Wook;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.485-489
    • /
    • 2010
  • Objective : To introduce the frequency and segment analysis of in-stent stenosis for intracranial stent assisted endovascular treatment on complex aneurysms. Methods : A retrospective study was performed in 158 patients who had intracranial complex aneurysms and were treated by endovascular stent application with or without coil embolization. Of these, 102 patients were evaluated with catheter based angiography after 6, 12, and 18 months. Aneurysm location, using stent, time to stenosis, stenosis rate and narrowing segment were analyzed. Results : Among follow-up cerebral angiography done in 102 patients, 8 patients (7.8%) were shown an in-stent stenosis. Two patients have unruptured aneurysm and six patients have ruptured one. Number of Neuroform stents were 7 cases (7.5%) and Enterprise stent in 1 case (11.1%). Six patients demonstrated in-stent stenosis at 6 months after stent application and remaining two patients were shown at 12 months, 18 months, respectively. Conclusion : In-stent stenosis can be confronted after intracranial stent deployment. In our study, no patient showed symptomatic stenosis and there were no patients who required to further treatment except continuing antiplatets medication. In-stent stenosis has been known to be very few when they are placed into the non-pathologic parent artery during the complex aneurysm treatment, but the authors found that it was apt to happen on follow up angiography. Although the related symptom was not seen in our cases, the luminal narrowing at the stented area may result the untoward hemodynamic event in the specific condition.

Endovascular Placement of Self-Expandable Stent-Graft for the Treatment of Aortic Aneurysms -2 cases- (자가팽창성 Stent-graft의 경관적 설치술을 이용한 대동맥류의 치료 -2 예 보고-)

  • 신현우;이재성
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.99-102
    • /
    • 2000
  • The usual treatment for aortic aneurysms is surgical replacement with a prosthetic graft; however the associated morbidity and mortality rates must be considered. Endovascular placement of self-expandable stent-graft is a safe noninvasive treatment that can be an alternative to the surgical repair, the postoperative course of the 2 cases of thoracoabdominal aortic aneurysms was uneventful and no complication has been associated with the stent-graft during the 17 months and 5 months follow-up studies,.

  • PDF

Endovascular Treatment of Wide-Necked Intracranial Aneurysms : Techniques and Outcomes in 15 Patients

  • Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • Objective : It is technically difficult to treat wide-necked intracranial aneurysms by the endovascular method. Various tools and techniques have been introduced to overcome the related technical limitations. The purpose of this study was to evaluate the radiologic and clinical results of widenecked intracranial aneurysm treatment using the endovascular method. Methods : Fifteen aneurysms in 15 patients were treated by the endovascular method from October 2009 to August 2010. Seven patients presented with subarachnoid hemorrhage (SAH), seven patients had unruptured aneurysms, and one patient had an intracerebral hemorrhage and intraventricular hemorrhage due to an incompletely clipped aneurysm. The mean dome-to-neck ratio was 1.1 (range, 0.6-1.7) and the mean height-to-neck ratio was 1.1 (range, 0.6-2.0). We used double microcatheters instead of a stent or a balloon for the first trial. When we failed to make a stable coil frame with two coils, we used a stent-assisted technique. Results : All aneurysms were successfully embolized. Eleven aneurysms (73%) were embolized by the double microcatheter technique without stent insertion, and four aneurysms (27%) were treated by stent-assisted coil embolization. One case had subclinical procedure-related intraoperative hemorrhage. Another case had procedure-related thromboembolism in the left distal anterior cerebral artery. During the follow-up period, one patient (7%) had a recanalized aneurysmal neck 12 months after coil embolization. The recurrent aneurysm was treated by stent-assisted coil embolization. Conclusion : We successfully treated 15 wide-necked intracranial aneurysms by the endovascular method. More clinical data with longer follow-up periods are needed to establish the use of endovascular treatment for wide-necked aneurysm.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Endovascular Stroke Therapy Focused on Stent Retriever Thrombectomy and Direct Clot Aspiration : Historical Review and Modern Application

  • Kang, Dong-Hun;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.3
    • /
    • pp.335-347
    • /
    • 2017
  • Intravenous recombinant tissue plasminogen activator had been the only approved treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time window, numerous contraindications, and its low recanalization rate were all limitations of this modality. Under those circumstances, endovascular stroke therapy went through a great evolution during the past two decades of intravenous thrombolysis. The results of the 2013 randomized trials for endovascular stroke therapy were neutral, although they were limited by insufficient imaging screening at enrollment, early-generation devices with less efficacy, and treatment delays. Huge progress was made in 2015, as there were five randomized clinical trials which all demonstrated the safety and efficacy of endovascular stroke treatment. Despite differences in detail patient enrollment criteria, all 5 trials employed key factors for good functional recovery; (1) screening with non-invasive imaging to identify the proximal occlusion and exclude a large infarct core, (2) using highly effective modern thrombectomy devices mainly with stent retriever, and (3) establishment of a fast workflow to achieve effective reperfusion. The results of those trials indicate that modern thrombectomy devices can allow for faster and more effective reperfusion, which can lead to improved clinical outcomes compared to intravenous thrombolysis alone. These advances in mechanical thrombectomy are promising in the global fight against ischemic stroke-related disability and mortality. Two current mainstreams among such mechanical thrombectomy techniques, "stent retriever thrombectomy" and "direct clot aspiration", are the topic of this review. Stent retriever thrombectomy using Solitaire and Trevo retriever will be firstly discussed. And, the commonalities and the differences between two major clot aspiration thrombectomy techniques; a direct aspiration first pass technique (ADAPT) and forced arterial suction thrombectomy (FAST), will be additionally explained. Finally, details regarding the combination of direct clot aspiration and stent retriever thrombectomy, the switching strategy and the Solumbra technique, will be described.

Endovascular Treatment for Common Iliac Artery Injury Complicating Lumbar Disc Surgery : Limited Usefulness of Temporary Balloon Occlusion

  • Nam, Taek-Kyun;Park, Seung-Won;Shim, Hyung-Jin;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.261-264
    • /
    • 2009
  • Vascular injury during lumbar disc surgery is a rare but potentially life-threatening complication. It has been managed by open vascular surgical repair. With recent technologic advance, endovascular treatment became one of effective treatment modalities. We present a case of a 32-year-old woman who suffered with common iliac artery injury during lumbar disc surgery that was treated successfully by endovascular repair with temporary balloon occlusion and subsequent insertion of a covered stent. Temporary balloon occlusion for 1.5 hours could stop bleeding, but growing pseudoaneurysm was identified at the injury site during the following 13 days. It seems that the temporary balloon occlusion can stall bleeding from arterial injury for considerable time duration, but cannot be a single treatment modality and requires subsequent insertion of a covered stent.

Stent-assisted coiling of a ruptured basilar artery perforator aneurysm: A case report

  • Jongwon Cho;Sang Hyun Suh;Joonho Chung
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.1
    • /
    • pp.81-86
    • /
    • 2023
  • Basilar artery (BA) perforator aneurysms are exceedingly rare causes of subarachnoid hemorrhage. Therefore, the natural history and optimal treatment have not been established, and surgical, endovascular, and conservative management have been used. However, there is no consensus on the optimal treatment strategy. Herein, we report the case of a 52-year-old man presenting with a ruptured BA perforator aneurysm. First, we deployed an Enterprise stent from the left P1 segment to the BA because the microcatheter could not enter the aneurysm. Then, we deployed a helical coil on the orifice of the BA perforator. Finally, we deployed another Enterprise stent, sandwiching the helical coil between the two Enterprise stents. The aneurysm was completely obliterated without recurrence on the follow-up angiography. Our technique of sandwiching the small helical coil between two Enterprise stents might help other surgeons by offering another feasible treatment option for ruptured BA perforator aneurysms.

Stent Graft Repair of Penetrated Injury of the Common Carotid Artery

  • Kim, Soon Jin;Ryu, Sang Woo;Chekar, Jaykey;Kim, Yong Tae;Seo, Bo Ra
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.172-175
    • /
    • 2016
  • Penetrated injury of common carotid artery (CCA) is rare and extremely lethal. Carotid artery injury tends to bleed actively and potentially occlude the trachea. It can cause fatal neurological complications. An accurate diagnosis and adequate treatment are very needed to the successful outcome of the penetrating vascular injury in zone 1, 2, and 3 of the neck. Open surgical treatment is more invasive and complicated than endovascular treatment. We experienced a case with penetrating injury in neck zone 2. Here, we report the case successfully treated with endovascular stent graft technique.

Endovascular Treatment by using Double Stent Method for Ruptured Vertebral Artery Dissecting Aneurysms

  • Kim, Sung-Hoon;Choi, Chang-Hwa;Lee, Tae-Hong;Lee, Sang-Weon
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.2
    • /
    • pp.132-135
    • /
    • 2005
  • We report two cases of patients with ruptured vertebral artery dissecting aneurysms that were treated using double overlapping stent placement. Angiography performed immediately after the procedure revealed a significant reduction of aneurysmal filling due to the intraaneurysmal thorombosis. In one case, complete disappearance of the lesion was observed after seven days and in the another one, the size of previous aneurysm sac was decreased on 7th post-procedure day. The reduced stent porosity caused by the overlapping stents, which result in significant hemodynamic changes inside aneurysmal sac, may accelerate intraanuerysmal thromobosis and may be helpful in achieving a more rapid complete occlusion of aneurysm. This double stent method may represent a therapeutic alternatives for dissecting vertebral artery aneurysm in which conventional endovascular techniques or stent supported coil embolization is not considered feasible and surgical treatment is contraindicated.

Jejunal Migration of the Stent-Graft Used for Common Hepatic Artery Pseudoaneurysm (총간동맥 가성동맥류의 치료로 삽입한 스텐트 그라프트의 공장으로의 위치 이동)

  • Jiwon Kim;Byung-Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.189-193
    • /
    • 2022
  • Hemorrhage after pancreaticobiliary surgery is an infrequent but fatal complication. It is primarily caused by rupture of the pseudoaneurysm, and treatment options include endovascular coil embolization or endovascular stent-graft placement. Herein, we report a case of migration of an arterial stent-graft that was placed in the common hepatic artery to treat pseudoaneurysm after pylorus-preserving pancreaticoduodenectomy. The stent-graft migrated to the jejunum and was eventually excreted from the body.