• Title/Summary/Keyword: Endoscopy, gastrointestinal

Search Result 590, Processing Time 0.023 seconds

Pediatric Endoscopic Sedation in Korea: A Survey of the Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition (소아청소년 진정내시경: 대한소아소화기영양학회 학술위원회 조사 보고)

  • Ryoo, Eell;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • Purpose: The aim of this survey was to analyze the choice of sedative drugs and their side effects during pediatric endoscopic sedation in Korea. We also evaluated doctors, caretakers and patient satisfaction with the procedures. Methods: Between June 2006 and July 2006, a 16-item survey regarding current sedation practices, during one month, was mailed to 28 hospitals in Korea. The results of the survey responses were then analyzed. Results: Endoscopy performed under conscious sedation was reported in 89.0% of the responders and endoscopy under general anesthesia in 0.9% of 465 endoscopic procedures. Endoscopy under conscious sedation was performed in 89.1% for upper gastrointestinal endoscopy (GFS) and 88.1% for lower GFS. Midazolam was used for conscious sedation during the endoscopy in 84.5% of cases and propofol was used in two cases (0.5%). In addition, a bezodiazepine/opioid combination was used iin 84.6% (44 cases) for lower GFS. Patients were monitored with pulse oxymetry, EKG (91.4%) as well as automatic BP (5.1%). Transient hypoxia was the only side effect noted and was treated with supplemental oxygen (4.6%). Flumazenil was used in 2.71% of cases. The choice of sedation was made by the endoscopist (84%). The satisfaction rate for endoscopists was 68%, and for the patients and caretakers was 84% (as reported by the endoscopists). Conclusion: Midazolam was used only for the upper GFS and benzodiazepine/opioid combination was used for the lower GFS in Korea. The rate of satisfaction was relatively high and there were no significant side effects noted during the endoscopy under conscious sedation.

  • PDF

Acute Gastritis and Splenic Infarction Caused by Epstein-Barr Virus

  • Jeong, Ji Eun;Kim, Kyung Moon;Jung, Hye Lim;Shim, Jae Won;Kim, Deok Soo;Shim, Jung Yeon;Park, Moon Soo;Park, Soo Kyung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.2
    • /
    • pp.147-153
    • /
    • 2018
  • Epstein-Barr virus (EBV) infection can be presented with various clinical manifestations and different levels of severity when infected. Infectious mononucleosis, which is most commonly caused by EBV infection in children and adolescents, is a clinical syndrome characterized by fatigue, malaise, fever, sore throat, and generalized lymphadenopathy. But rarely, patients with infectious mononucleosis may present with gastrointestinal symptoms and complicated by gastritis, splenic infarction, and splenic rupture. We encountered a 16-year-old girl who presented with fever, fatigue, and epigastric pain. Splenic infarction and EBV-associated gastritis were diagnosed by using esophagogastroduodenoscopy and abdominal computed tomography. Endoscopy revealed a generalized hyperemic nodular lesion in the stomach, and the biopsy findings were chronic gastritis with erosion and positive in situ hybridization for EBV. As splenic infarction and acute gastritis are rare in infectious mononucleosis and are prone to be overlooked, we must consider these complications when an infectious mononucleosis patient presents with gastrointestinal symptom.

Comparative Study of Carcinoembryonic Antigen Tumor Marker in Stomach and Colon Cancer Patients in Khyber Pakhtunkhwa

  • Ahmad, Bashir;Gul, Bushra;Ali, Sajid;Bashir, Shumaila;Mahmood, Nourin;Ahmad, Jamshed;Nawaz, Seema
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4497-4502
    • /
    • 2015
  • Background: Due to the increase in morbidity and mortality rate, cancer has become an alarming threat to the human population worldwide. Since cancer is a progressive disorder, timely diagnosis would be helpful to prevent/stop cancer from progressing to severe stage. In Khyber Pakhtunkhwa, Pakistan, most of the time, tumors are diagnosed with endoscopy and biopsy; therefore rare studies exist regarding the diagnosis of gastrointestinal (GIT) carcinomas based on tumor markers, especially CEA. Objectives: This study made a comparative analysis of CEA in admitted hospitalized stomach and colon cancer patients diagnosed as GIT with biopsy. Materials and Methods: In this study, a total of 66 cases were included. The level of CEA was determined in the blood of these patients using ELISA technique. Results: Out of 66 patients, the level of CEA was high in 59.1% of the total, 60.7% in colon cancer patients and 57.9 % in stomach cancer patients. Moreover, the incidence of colorectal and stomach cancer was greater in males as compared to females. Patients were more of the age group of 40-60 and the level of CEA was comparatively higher in patients (51.5%) with histology which was moderately differentiated, than patients with well differentiated and poorly differentiated tumor histology. Conclusions: CEA level was high in more than 50% of the total patients. Moreover, CEA exhibited higher sensitivity for colon than stomach cancer.

Diagnostic Value of Fecal Calprotectin as a Screening Biomarker for Gastrointestinal Malignancies

  • Khoshbaten, Manouchehr;Pishahang, Parinaz;Nouri, Mohammad;Lashkari, Alireza;Alizadeh, Mahasti;Rostami-Nejad, Mohammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1667-1670
    • /
    • 2014
  • Background: Calprotectin in feces seems to be a more sensitive marker for gastrointestinal (GI) cancers than fecal occult blood, but its specificity may be too low for screening average risk populations. This study aims at evaluating the diagnostic value of fecal calprotectin as a screening biomarker for GI malignancies. Materials and Methods: In a case-control study, 100 patients with GI malignancies (50 patients with colorectal cancer and 50 patients with gastric cancer) and 50 controls were recruited in Tabriz Imam Reza and Sina hospitals during a 24-month period. One to two weeks after the last endoscopy/colonoscopy, fecal specimens were collected by the patients and examined by ELISA method for quantitative measurement of calprotectin content. The results were compared between the three groups. Results: The mean fecal calprotectin level was $109.1{\pm}105.3$ (2.3-454.3, median:74), $241.1{\pm}205.2$ (3.4-610.0, median:19.3) and $45.9{\pm}55.1{\mu}g/g$ (1.3-257.1, median:19.3) in gastric cancer, colorectal cancer and control group, respectively, the differences being significant (p<0.001) and remaining after adjustment for age. The optimal cut-off point for fecal calprotectin was ${\geq}75.8{\mu}g/g$ for distinguishing colorectal cancer from normal cases (sensitivity and specificity of 80% and 84%, respectively). This value was ${\geq}41.9{\mu}g/g$ for distinguishing gastric cancer from normal cases (sensitivity and specificity of 62%). Conclusions: Our results revealed that fecal calprotectin might be a useful and non-invasive biomarker for distinguishing colorectal cancer from non-malignant GI conditions. However, due to low sensitivity and specificity, this biomarker may not help physicians distinguishing gastric cancer cases from healthy subjects.

FOREIGN BODY INGESTION DURING DENTAL TREATMENT IN PEDIATRIC PATIENT (치과치료시 발생한 이물질 삼킴에 대한 치험례)

  • Kim, Sun-Ha;Choi, Sung-Chul;Park, Jae-Hong;Kim, Kwang-Chul
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.7 no.1
    • /
    • pp.29-32
    • /
    • 2011
  • There are a lot of dental emergency situations and accidental aspiration or ingestion of a dental instrument is one of the common accidents in dental practice especially on disabied or pediatric patient with negative behavior. Most of ingested foreign bodies pass through the gastrointestinal tract spontaneously, but some of them (about 20%) need endoscopic or surgical removal. This is a case of an accident during the treatment of a 18 months male patient with caries of anterior deciduous teeth. During the treatment, the gauze was used by waterproofing instead of a rubber dam. #4 round bur (approximately 2.2cm long) which was put on the tray was cling to the gauze and the bur was fell into the patient's throat. The bur was 2.2cm long and very sharp so it could not be passed spontaneously through the pylorus, so we tried to remove the bur by esophagogastroduodenoscopy. Endoscopic removal of foreign bodies in the upper gastrointestinal tract is an effective and safe procedure.

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

Incidentally Diagnosed Duodenal Web in Infancy (영아기에 우연히 진단된 십이지장 격막)

  • Suh Young Kim;Byoung Hee Han;Ki Young Park;Jung-Man Namgoong;Da Hee Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.724-729
    • /
    • 2022
  • A duodenal web is an incomplete diaphragm of the duodenal lumen that causes a partial or (intermittent) complete obstruction. The size of a duodenal web's aperture determines the degree of obstruction, age at presentation, and radiologic findings. We report a case of duodenal web incidentally diagnosed in a 14-month-old boy who presented to the hospital after ingesting a foreign body. We provide a comprehensive report of multiple studies through abdominal radiograph, upper gastrointestinal study, endoscopy, and surgical findings. We emphasize that the duodenum should be considered as the location of the obstruction when infants exhibit delayed discharge or dynamic positioning of a foreign body in a radiologic examination.

A Study on the Comparison of Learning Performance in Capsule Endoscopy by Generating of PSR-Weigted Image (폴립 가중치 영상 생성을 통한 캡슐내시경 영상의 학습 성능 비교 연구)

  • Lim, Changnam;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.6
    • /
    • pp.251-256
    • /
    • 2019
  • A capsule endoscopy is a medical device that can capture an entire digestive organ from the esophagus to the anus at one time. It produces a vast amount of images consisted of about 8~12 hours in length and more than 50,000 frames on a single examination. However, since the analysis of endoscopic images is performed manually by a medical imaging specialist, the automation requirements of the analysis are increasing to assist diagnosis of the disease in the image. Among them, this study focused on automatic detection of polyp images. A polyp is a protruding lesion that can be found in the gastrointestinal tract. In this paper, we propose a weighted-image generation method to enhance the polyp image learning by multi-scale analysis. It is a way to extract the suspicious region of the polyp through the multi-scale analysis and combine it with the original image to generate a weighted image, that can enhance the polyp image learning. We experimented with SVM and RF which is one of the machine learning methods for 452 pieces of collected data. The F1-score of detecting the polyp with only original images was 89.3%, but when combined with the weighted images generated by the proposed method, the F1-score was improved to about 93.1%.

Performance comparison between two computer-aided detection colonoscopy models by trainees using different false positive thresholds: a cross-sectional study in Thailand

  • Kasenee Tiankanon;Julalak Karuehardsuwan;Satimai Aniwan;Parit Mekaroonkamol;Panukorn Sunthornwechapong;Huttakan Navadurong;Kittithat Tantitanawat;Krittaya Mekritthikrai;Salin Samutrangsi;Peerapon Vateekul;Rungsun Rerknimitr
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.217-225
    • /
    • 2024
  • Background/Aims: This study aims to compare polyp detection performance of "Deep-GI," a newly developed artificial intelligence (AI) model, to a previously validated AI model computer-aided polyp detection (CADe) using various false positive (FP) thresholds and determining the best threshold for each model. Methods: Colonoscopy videos were collected prospectively and reviewed by three expert endoscopists (gold standard), trainees, CADe (CAD EYE; Fujifilm Corp.), and Deep-GI. Polyp detection sensitivity (PDS), polyp miss rates (PMR), and false-positive alarm rates (FPR) were compared among the three groups using different FP thresholds for the duration of bounding boxes appearing on the screen. Results: In total, 170 colonoscopy videos were used in this study. Deep-GI showed the highest PDS (99.4% vs. 85.4% vs. 66.7%, p<0.01) and the lowest PMR (0.6% vs. 14.6% vs. 33.3%, p<0.01) when compared to CADe and trainees, respectively. Compared to CADe, Deep-GI demonstrated lower FPR at FP thresholds of ≥0.5 (12.1 vs. 22.4) and ≥1 second (4.4 vs. 6.8) (both p<0.05). However, when the threshold was raised to ≥1.5 seconds, the FPR became comparable (2 vs. 2.4, p=0.3), while the PMR increased from 2% to 10%. Conclusions: Compared to CADe, Deep-GI demonstrated a higher PDS with significantly lower FPR at ≥0.5- and ≥1-second thresholds. At the ≥1.5-second threshold, both systems showed comparable FPR with increased PMR.

Efficacy of the pocket-creation method with a traction device in endoscopic submucosal dissection for residual or recurrent colorectal lesions

  • Daisuke Ide;Tomohiko Richard Ohya;Mitsuaki Ishioka;Yuri Enomoto;Eisuke Nakao;Yuki Mitsuyoshi;Junki Tokura;Keigo Suzuki;Seiichi Yakabi;Chihiro Yasue;Akiko Chino;Masahiro Igarashi;Akio Nakashima;Masayuki Saruta;Shoichi Saito;Junko Fujisaki
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.655-664
    • /
    • 2022
  • Background/Aims: Endoscopic submucosal dissection (ESD) for residual or recurrent colorectal lesions after incomplete resection is challenging because of severe fibrosis. This study aimed to compare the efficacy of the pocket-creation method (PCM) with a traction device (TD) with that of conventional ESD for residual or recurrent colorectal lesions. Methods: We retrospectively studied 72 patients with residual or recurrent colorectal lesions resected using ESD. Overall, 31 and 41 lesions were resected using PCM with TD and conventional ESD methods, respectively. We compared patient background and treatment outcomes between the PCM with TD and conventional ESD groups, respectively. The primary endpoints were en bloc resection and R0 resection rates. The secondary endpoints were the dissection speed and incidence of adverse events. Results: En bloc resection was feasible in all cases with PCM with TD, but failed in 22% of cases of conventional ESD. The R0 resection rates for PCM with TD and conventional ESD were 97% and 66%, respectively. Dissection was significantly faster in the PCM with TD group (13.0 vs. 7.9 mm2/min). Perforation and postoperative bleeding were observed in one patient in each group. Conclusions: PCM with TD is an effective method for treating residual or recurrent colorectal lesions after incomplete resection.