• Title/Summary/Keyword: Endoscopy, gastrointestinal

Search Result 565, Processing Time 0.026 seconds

Have we Comprehensively Evaluated the Effectiveness of Endoscopic Screening for Gastric Cancer?

  • Hamashima, Chisato
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3591-3592
    • /
    • 2015
  • Endoscopy has been increasingly used in clinical practice and as a standardized examination procedure for gastrointestinal diseases. However, only a few studies on endoscopic screening for evaluating mortality reduction from gastric cancer have been carried out. Even if a high detection rate is obtained in clinical practice, such a rate cannot be directly accepted as evidence providing the effectiveness of cancer screening. Endoscopic screening for gastric cancer is not an exception of possibility to detect overdiagnosis. If detection rate is used for the evaluation of the effectiveness of cancer screening, the possibility of overestimating the effectiveness of cancer screening cannot be ruled out. To avoid the effect of overdiagnosis and confirm the effectiveness of endoscopic screening, mortality reduction from gastric cancer must be carefully evaluated by conducting reliable studies. The burden of gastric cancer remains real and this cannot be ignored in Eastern Asian countries. To determine the best available method for gastric cancer screening, evaluation of its effectiveness is a must. Endoscopic screening for gastric cancer has shown promising results, and thus deserves further comprehensive evaluation to reliably confirm its effectiveness and how its optimal use can be strategically promoted.

Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure

  • Harima, Hirofumi;Hamabe, Kouichi;Hisano, Fusako;Matsuzaki, Yuko;Itoh, Tadahiko;Sanuki, Kazutoshi;Sakaida, Isao
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.596-599
    • /
    • 2018
  • An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

Analysis and Evaluation of Slanted-edge-based Modulation Transfer Function and Focus Measurements for Optimal Assembly of Imaging Modules in Gastrointestinal Endoscopy

  • Wonju Lee;Ki Young Shin;Dong-Goo Kang;Minhye Chang;Young Min Bae
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.398-407
    • /
    • 2023
  • We explored a method to evaluate imaging performance for the optimal assembly of an endoscopic miniature lens and a sensor constituting an imaging module at the distal end of gastrointestinal endoscopy. For the assembly of the imaging module, the image sensor was precisely located at the focal plane when collimated light passed through the endoscopic lens. As another method, the distance between the lens and sensor was adjusted to obtain the highest focus index from images measured the star chart of the International Organization for Standardization (ISO) standard at various positions. We analyzed the slanted-edge modulation transfer function (MTF), corresponding depth of field, and number of line pairs for MTF 50% and 20% at each working distance within the range of 5-100 mm for imaging modules assembled in different ways. Assembly conditions of the imaging module with better MTF performance were defined for each working distance range of 5-30 mm and 30-100 mm, respectively. In addition to the MTF performance, the focus index of each assembled module was also compared. In summary, we examined the performance of imaging modules assembled with different methods within the suggested working distance and tried to establish the optimal assembly protocol.

Mucosal incision-assisted biopsy versus endoscopic ultrasound-assisted tissue acquisition for subepithelial lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.615-625
    • /
    • 2022
  • Background/Aims: Mucosal incision-assisted biopsy (MIAB) for tissue acquisition (TA) from subepithelial lesions (SELs) is emerging as an alternative to endoscopic ultrasound (EUS)-guided TA. Only a limited number of studies compared the diagnostic utility of MIAB and EUS for upper gastrointestinal (GI) SELs; therefore, we conducted this systematic review and meta-analysis. Methods: A comprehensive literature search from January 2020 to January 2022 was performed to compare the diagnostic accuracy and safety of MIAB and EUS-guided TA for upper GI SELs. Results: Seven studies were included in this meta-analysis. The pooled technical success rate (risk ratio [RR], 0.96; 95% confidence interval [CI], 0.89-1.04) and procedural time (mean difference=-4.53 seconds; 95% CI, -22.38 to 13.31] were comparable between both the groups. The overall chance of obtaining a positive diagnostic yield was lower with EUS than with MIAB for all lesions (RR, 0.83; 95% CI, 0.71-0.98) but comparable when using a fine-needle biopsy needle (RR, 0.93; 95% CI, 0.83-1.04). The positive diagnostic yield of MIAB was higher for lesions <20 mm (RR, 0.75; 95% CI, 0.63-0.89). Six studies reported no adverse events. Conclusions: MIAB can be considered an effective alternative to EUS-guided TA for upper GI SELs without an increased risk of adverse events.

Comparison of conventional and new endoscopic band ligation devices for colonic diverticular bleeding

  • Ayaka Takasu;Takashi Ikeya;Yasutoshi Shiratori
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.408-416
    • /
    • 2022
  • Background/Aims: Endoscopic band ligation (EBL) is used to treat colonic diverticular bleeding (CDB). An endoscopic variceal ligation device for esophageal varices is used as a conventional EBL device (C-EBL). A new EBL device (N-EBL) was developed by Sumitomo Bakelite Co. in August 2018. We aimed to evaluate the clinical outcomes of N-EBL compared with those of C-EBL. Methods: Seventy-nine patients who underwent EBL for CDB at St. Luke's International Hospital, Japan, between 2017 and 2020 were included in this retrospective study. Patients were divided into the C-EBL and N-EBL groups. Their clinical outcomes, including achieving initial hemostasis, early rebleeding, procedure time, and EBL-associated adverse events, were evaluated. Results: Of the 79 patients, 36 (45.6%) were in the C-EBL group and 43 (54.4%) were in the N-EBL group. The rate of achieving initial hemostasis was 100% in the C-EBL group and 93.0% in the N-EBL group. No significant difference was noted in the early rebleeding rate between the groups (p=0.24). The N-EBL group achieved a shorter median EBL procedure time than the C-EBL group (14.2 minutes vs. 18.2 minutes, p=0.02). No adverse events were observed in either group. Conclusions: The N-EBL device is safe and useful and may reduce EBL procedure time.

Current and Future Technologies for a Gastrointestinal Endoscopy (소화기 내시경의 기술 현황과 전망)

  • Chee, Young-Joon;Woo, Jih-Wan
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.335-343
    • /
    • 2010
  • This article presents a review of technologies for an endoscope. The classification according to the clinical applications and the imaging modalities are summarized. The major parts are focused on describing the gastrointestinal endoscope's structures and mechanisms. The details of the image enhanced endoscopic techniques, such as NBI (narrow band imaging), OCT (optical coherence tomography), and EUS (endoscopic ultrasound), are also explained. Finally, the trend of NOTES (natural orifice transluminal endoscopic surgery) which is new fusion technology in the field of endoscopic diagnosis and surgery is introduced.

Incidentally Discovered Solitary Gastrointestinal Polyp with Pathological Significance in Children: Four Case Reports

  • Han, Sang-eun;Chang, Jiyeon;Paik, Seung Sam;Kim, Yong Joo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.3
    • /
    • pp.209-213
    • /
    • 2018
  • Most solitary gastrointestinal (GI) polyps in children are either inflammatory or hamartomatous. Solitary hyperplastic polyp, sentinel polyp and solitary adenomatous polyp have been occasionally diagnosed in adults, but very rarely reported in Korean children. We recently came across a case with adenomatous polyp in the colon, a case with hyperplastic polyp beneath the gastroesophageal junction, a case with hyperplastic polyp in the prepyloric area, and a case with sentinel polyp in the distal esophagus, which are unusual pathologic types in children. These mucosal lesions were diagnosed incidentally during elective endoscopic examinations for GI symptoms. Most polyps do not cause significant symptoms, so the diagnosis might be delayed, especially in children, in whom GI endoscopy is not commonly performed for screening purpose as in the adults.

Gastric Duplication Cyst Presenting as Massive Gastrointestinal Bleeding

  • Youssef, Alexey;Ibrahim, Alexander;AlShehabi, Zuheir;Omran, Ammar;Sharara, Ala I.
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.2
    • /
    • pp.189-192
    • /
    • 2019
  • Gastric duplication cysts (GDCs) are rare congenital anomalies. Presentation of GDCs varies from an asymptomatic abdominal mass to fulminant or massive gastrointestinal (GI) bleeding. Herein, we describe a case of a GDC in a 10-month-old infant presenting with unexplained massive GI hemorrhage and hematemesis. An abdominal ultrasound was negative, while computerized tomography was, initially, inaccessible. Through a series of repeated esophagogastroduodenoscopies, we documented penetration of the GDC into the gastric cavity that was later confirmed by computerized tomography. The patient was treated successfully with surgical resection.

Management of Gastrointestinal Foreign Bodies with Brief Review of the Guidelines

  • Kaan Demiroren
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Foreign body (FB) ingestion is a common health problem that affects children more than adults. According to gastroenterologists' guidelines, the management of FB ingestion differs slightly between adult and children. This review aimed to compile adult and children guidelines and establish an understandable association to reveal the requirements and timing of the endoscopic procedure, which is the most effective and least complicated technique for gastrointestinal FBs. Coins, pins, and chicken and fish bones have been the most commonly ingested FBs. However, with their increasing use in recent years, large batteries with lithiumion conversion, stronger magnets composed of rare earth metals, such as neodymium, and superabsorbent objects have become the most morbid and mortal, necessitating new management strategies. Although the approach to gastrointestinal FBs is controversial, with different treatment options available in different disciplines, many studies have demonstrated the efficacy and safety of endoscopic procedures. Many factors influence the timing of endoscopy, including the nature, size, and location of the ingested object and the patient's clinical condition.

Upper Endoscopy up to 3 Years Prior to a Diagnosis of Gastric Cancer Is Associated With Lower Stage of Disease in a USA Multiethnic Urban Population, a Retrospective Study

  • Shah, Shailja C.;Nakata, Chiaki;Polydorides, Alexandros D.;Peek, Richard M. Jr;Itzkowitz, Steven H.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.3
    • /
    • pp.179-187
    • /
    • 2019
  • Objectives: In the USA, certain races and ethnicities have a disproportionately higher gastric cancer burden. Selective screening might allow for earlier detection and curative resection. Among a USA-based multiracial and ethnic cohort diagnosed with non-cardia gastric cancer (NCGC), we aimed to identify factors associated with curable stage disease at diagnosis. Methods: We retrospectively identified endoscopically diagnosed and histologically confirmed cases of NCGC at Mount Sinai Hospital in New York City. Demographic, clinical, endoscopic and histologic factors, as well as grade/stage of NCGC at diagnosis were documented. The primary outcome was the frequency of curable-stage NCGC (stage 0-1a) at diagnosis in patients with versus without an endoscopy negative for malignancy prior to their index exam diagnosing NCGC. Additional factors associated with curable-stage disease at diagnosis were determined. Results: A total of 103 racially and ethnically diverse patients were included. Nearly 38% of NCGC were stage 0-Ia, 34% stage Ib-III, and 20.3% stage IV at diagnosis. A significantly higher frequency of NCGC was diagnosed in curable stages among patients who had undergone an endoscopy that was negative for malignancy prior to their index endoscopy that diagnosed NCGC, compared to patients without a negative endoscopy prior to their index exam (69.6% vs. 28.6%, p=0.003). A prior negative endoscopy was associated with 94.0% higher likelihood of diagnosing curable-stage NCGC (p=0.003). No other factors analyzed were associated with curablestage NCGC at diagnosis. Conclusions: Endoscopic screening and surveillance in select high-risk populations might increase diagnoses of curable-stage NCGC. These findings warrant confirmation in larger, prospective studies.