• 제목/요약/키워드: Endoscopic ultrasound

검색결과 85건 처리시간 0.016초

Role of interventional endoscopic ultrasound in a developing country

  • Hasan Maulahela;Nagita Gianty Annisa;Achmad Fauzi;Kaka Renaldi;Murdani Abdullah;Marcellus Simadibrata;Dadang Makmun;Ari Fahrial Syam
    • Clinical Endoscopy
    • /
    • 제56권1호
    • /
    • pp.100-106
    • /
    • 2023
  • Background/Aims: Endoscopic ultrasound (EUS) has become an essential diagnostic and therapeutic tool. EUS was introduced in 2013 in Indonesia and is considered relatively new. This study aimed to describe the current role of interventional EUS at our hospital as a part of the Indonesian tertiary health center experience. Methods: This retrospective study included all patients who underwent interventional EUS (n=94) at our center between January 2015 and December 2020. Patient characteristics, technical success, clinical success, and adverse events associated with each type of interventional EUS procedure were evaluated. Results: Altogether, 94 interventional EUS procedures were performed at our center between 2015 and 2020 including 75 cases of EUS-guided biliary drainage (EUS-BD), 14 cases of EUS-guided pancreatic fluid drainage, and 5 cases of EUS-guided celiac plexus neurolysis. The technical and clinical success rates of EUS-BD were 98.6% and 52%, respectively. The technical success rate was 100% for both EUS-guided pancreatic fluid drainage and EUS-guided celiac plexus neurolysis. The adverse event rates were 10.6% and 7.1% for EUS-BD and EUS-guided pancreatic fluid drainage, respectively. Conclusions: EUS is an effective and safe tool for the treatment of gastrointestinal and biliary diseases. It has a low rate of adverse events, even in developing countries.

No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis

  • Shyam Vedantam;Rahil Shah;Sean Bhalla;Shria Kumar;Sunil Amin
    • Clinical Endoscopy
    • /
    • 제56권3호
    • /
    • pp.298-307
    • /
    • 2023
  • Background/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. Results: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%-95.2%) and 92.1% (95% CI, 68.4%-98.4%), clinical success rates of 88.6% (95% CI, 85.4%-91.1%) and 89.6% (95% CI, 79.0%-95.1%), adverse event rates of 11.4% (95% CI, 8.1%-15.9%) and 14.7% (95% CI, 4.4%-39.1%), and reintervention rates of 10.3% (95% CI, 6.7%-15.4%) and 3.5% (95% CI, 1.6%-7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40-9.18; p=0.008). Conclusions: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.

22-gauge Co-Cr versus stainless-steel Franseen needles for endoscopic ultrasound-guided tissue acquisition in patients with solid pancreatic lesions

  • Yuki Tanisaka;Masafumi Mizuide;Akashi Fujita;Ryuhei Jinushi;Rie Shiomi;Takahiro Shin;Kei Sugimoto;Tomoaki Tashima;Yumi Mashimo;Shomei Ryozawa
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.237-245
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions. Methods: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S). Results: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03). Conclusions: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions

  • Seigo Nakatani;Kosuke Okuwaki;Masafumi Watanabe;Hiroshi Imaizumi;Tomohisa Iwai;Takaaki Matsumoto;Rikiya Hasegawa;Hironori Masutani;Takahiro Kurosu;Akihiro Tamaki;Junro Ishizaki;Ayana Ishizaki;Mitsuhiro Kida;Chika Kusano
    • Clinical Endoscopy
    • /
    • 제57권1호
    • /
    • pp.89-95
    • /
    • 2024
  • Background/Aims: In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs). Methods: In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA's diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs. Results: The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture. Conclusions: Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.

Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration

  • Mitsuru Okuno;Keisuke Iwata;Tsuyoshi Mukai;Yusuke Kito;Takuji Tanaka;Naoki Watanabe;Senji Kasahara;Yuhei Iwasa;Akihiko Sugiyama;Youichi Nishigaki;Yuhei Shibata;Junichi Kitagawa;Takuji Iwashita;Eiichi Tomita;Masahito Shimizu
    • Clinical Endoscopy
    • /
    • 제57권3호
    • /
    • pp.364-374
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML). Methods: Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles. Results: Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1-6] vs. 4 [1-6], p=0.023). There were no significant differences in cytological/ histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group. Conclusions: Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.

Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of patients with biliary tract cancer, especially with intrahepatic cholangiocarcinoma

  • Takafumi Yanaidani;Kazuo Hara;Nozomi Okuno;Shin Haba;Takamichi Kuwahara;Yasuhiro Kuraishi;Nobumasa Mizuno;Sho Ishikawa;Masanori Yamada;Tsukasa Yasuda
    • Clinical Endoscopy
    • /
    • 제57권3호
    • /
    • pp.384-392
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a standard diagnostic method for biliary tract cancer (BTC), and samples obtained in this manner may be used for comprehensive genomic profiling (CGP). This study evaluated the utility of EUS-TA for CGP in a clinical setting and determined the factors associated with the adequacy of CGP in patients with BTC. Methods: CGP was attempted for 105 samples from 94 patients with BTC at the Aichi Cancer Center, Japan, from October 2019 to April 2022. Results: Overall, 77.1% (81/105) of the samples were adequate for CGP. For 22-G or 19-G fine-needle biopsy (FNB), the sample adequacy was 85.7% (36/42), which was similar to that of surgical specimens (94%, p=0.45). Univariate analysis revealed that 22-G or larger FNB needle usage (86%, p=0.003), the target primary lesions (88%, p=0.015), a target size ≥30 mm (100%, p=0.0013), and number of punctures (90%, p=0.016) were significantly positively associated with CGP sample adequacy. Conclusions: EUS-TA is useful for CGP tissue sampling in patients with BTC. In particular, the use of 22-G or larger FNB needles may allow for specimen adequacy comparable to that of surgical specimens.

Endoscopic Resection of Xanthogranulomatous Gastritis Presenting as a Subepithelial Tumor: A Case Report

  • Kim, Tae Wan;Kim, Tae Ho;Kim, Chang Whan;Chang, Jae Hyuck;Han, Sok Won;Kim, Jae Kwang
    • 대한상부위장관⦁헬리코박터학회지
    • /
    • 제18권3호
    • /
    • pp.198-203
    • /
    • 2018
  • Xanthogranulomatous gastritis (XGG) presenting as a subepithelial tumor (SET) is a very rare entity. We report a case of SET-like XGG diagnosed and treated with endoscopic resection. A 55-year-old female patient was initially referred with a 1.5-cm SET located at the anterior wall of the middle antrum. Endoscopic ultrasound examination revealed submucosal invasion without any perigastric lymph node enlargement. Endoscopic resection was performed for an accurate diagnosis and treatment, and the lesion was diagnosed histopathologically as XGG. At the 18-month follow-up after endoscopic resection, there was no evidence of XGG recurrence. SET-like XGG is very rare and the diagnosis is a preoperative challenge. However, inflammatory tumors should be considered in the differential diagnosis of SET.

Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction

  • Taro Shibuki;Kei Okumura;Masanari Sekine;Ikuhiro Kobori;Aki Miyagaki;Yoshihiro Sasaki;Yuichi Takano;Yusuke Hashimoto
    • Clinical Endoscopy
    • /
    • 제56권6호
    • /
    • pp.802-811
    • /
    • 2023
  • Background/Aims: Covered self-expandable metallic stents (cSEMS) have become popular for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting (EUS-HGS). We compared the time to recurrent biliary obstruction (TRBO), complications, and reintervention rates between EUS-HGS using plastic stent (PS) and cSEMS in patients with unresectable malignancies at multicenter institutions in Japan. Methods: Patients with unresectable malignant biliary obstruction who underwent EUS-HGS between April 2015 and July 2020 at any of the six participating facilities were enrolled. Primary endpoint: TRBO; secondary endpoints: rate of complications other than recurrent biliary obstruction and technical success rate of reintervention were evaluated. Results: PS and cSEMS were used for EUS-HGS in 109 and 43 patients, respectively. The TRBO was significantly longer in the cSEMS group than in the PS group (646 vs. 202 days). Multivariate analysis identified two independent factors associated with a favorable TRBO: combined EUS-guided antegrade stenting with EUS-HGS and the use of cSEMS. No significant difference was observed in the rate of complications other than recurrent biliary obstruction between the two groups. The technical success rate of reintervention was 85.7% for PS and 100% for cSEMS (p=0.309). Conclusions: cSEMS might be a better option for EUS-HGS in patients with unresectable malignancies, given the longer TRBO.