• Title/Summary/Keyword: Endoscopic Image

Search Result 89, Processing Time 0.036 seconds

Development of Digital Endoscopic Data Management System (디지탈 내시경 데이터 management system의 개발)

  • Song, C.G.;Lee, S.M.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.304-306
    • /
    • 1996
  • Endoscopy has become a crucial diagnostic and theraputic procedure in clinical areas. Over the past three years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholesystectomy, peviscopic endometriosis, and surgical arthroscopy. In this study, we are developed computer system, which is composed of frame grabber, sound board, VCR control board, LAN card and EDMS(endoscopic data management software). Also, computer system has controled over peripheral instruments as a color video printer, video cassette recorder, and endoscopic input/output signals(image and doctor's speech). Also, we are developed one body system of camels control unit including an endoscopic miniature camera and light source. Our system offer unsurpassed image quality in terms of resolution and color fidelity. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards, namely: windows 3.1 as a operating system, TCP/IP as a network protocol and a time sequence based database that handles both an image and drctor's speech synchronized with endoscopic image.

  • PDF

Development of Digital Endoscopic Image Processing System (디지탈 내시경 영상처리 시스템의 개발)

  • 송철규;이영묵
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.121-126
    • /
    • 1997
  • Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past three years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame yabber, a sound board, a VCR control board, a LAN card and EDMS(endoscopic data management software. Also, computer system has controled peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals(image and doctor's comment). Digital endoscopic data management system is based on open architecture and a set of widely available industry standards, namely: windows 3.1 as a operating system, TCP/IP as a network protocol and a time sequence based database that handles both images and doctor's cotnments. For the purpose of data storage, we used MOD and CD-R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images.

  • PDF

Evaluation of Coding Performance and Design of Spatial Multiplexer or 3D Endoscopic Image Processing (3D 내시경 영상처리를 위한 다중화기 설계와 부호화 성능평가)

  • Song, C.G.;Lee, S.M.;Lee, Y.M.;Kim, W.K.;Hwang, J.D.;Kim, J.H.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.137-141
    • /
    • 1997
  • In this study, in order to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery, three dimensional endoscopic system is designed. These 3D systems have our features of stereoendoscopic image processing: real time image capture and retrieve; presentation of left and right image on a single monitor; separable processing of the left and right eye images; coding of the 3D endoscopic video. For 3D endoscopic video coding, three approaches are presented based on interlaced picture structure, side-field format structure, and simulcast technique. Experimental results and performances comparisons are presented and analyzed or these approaches. Digital video coding techniques are presented or 3D endoscopic video sequences by means of an MPEG-2 video coding.

  • PDF

The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

  • Park, Soon-Hong;Sung, Sang-Hun;Lee, Seung-Jun;Jung, Min-Kyu;Kim, Sung-Kook;Jeon, Seong-Woo
    • Journal of Gastric Cancer
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 2012
  • Purpose: Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods: Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results: The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions: The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection.

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.4
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

Current and Future Technologies for a Gastrointestinal Endoscopy (소화기 내시경의 기술 현황과 전망)

  • Chee, Young-Joon;Woo, Jih-Wan
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.335-343
    • /
    • 2010
  • This article presents a review of technologies for an endoscope. The classification according to the clinical applications and the imaging modalities are summarized. The major parts are focused on describing the gastrointestinal endoscope's structures and mechanisms. The details of the image enhanced endoscopic techniques, such as NBI (narrow band imaging), OCT (optical coherence tomography), and EUS (endoscopic ultrasound), are also explained. Finally, the trend of NOTES (natural orifice transluminal endoscopic surgery) which is new fusion technology in the field of endoscopic diagnosis and surgery is introduced.

A performance Evaluation and Development of 3D Endoscopic Imaging system

  • Song, Chul-Gyo;Kim, Kyeong-Seop;Kim, Nam-Gyun;Lee, Myoung-Ho
    • Journal of KIEE
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • This paper represents the design of 3D endoscopic video system in order to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In comparison of the polarized and electric shutter-type stereo imaging system, The former is superior in terms of accuracy and performance speed for knot-tying and loop pass test. The result of experiments show that the proposed 3D endoscopy system has a wide viewing angle and zone which is necessary for multi-view and it has better image quality and stability of the optical performances than the electric shutter-type does.

  • PDF

Development of Peripheral Devices on the Endoscopic Surgery System (내시경 수술시스템의 주변장치 개발)

  • Lee, Young-Mook;Song, Chul-Gyu;Lee, Sang-Min;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

Development of Stereo PACS Viewer for the 3-D Endoscopic Image

  • Kim, Jeonghoon;Lee, Junyoung;Lee, Sungjae;Lee, Myoungho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.181.2-181
    • /
    • 2001
  • Stereo PACS (Picture Archiving and Communication System) is not available yet because of some limitations of medical stereo image software and viewing devices. As a stereo PACS viewer, we designed two functions. One is selecting and viewing a multiplexed stereo image directly, and the other is selecting a stereo pair image (left and right sides both) and merging the stereo pair image into a multiplexed image in software. For the medical image compression of 3-D stereo endoscopic images, we used JPEG and Wavelet compression and to determine an acceptable compression rate using PSNR (Peak Signal-to-Noise Ratio). As a result, we got the conclusion that medically acceptable image compression rate should have the PSNR of above about 40[dB] (JPEG (5:1), Wavelet (10:1)).

  • PDF

Segmentation using Snakes on Digital Endoscopic Image (Snake를 이용한 디지털 내시경 영상의 분할)

  • Yoon, S.W.;Kim, J.H.;Choi, J.J.;Yoon, Y.S.;Lee, J.Y.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2715-2717
    • /
    • 2002
  • Image segmentation is an essential technique of image analysis. In spite of the issues in contour initialization and boundary concavities, active contour models(snakes) are popular and successful methods for the segmentation. In this paper, we present a new active contour model, GGF snake, for segmentation of endoscopic image. The GGF snake is less sensitive to contour initialization and ensures high accuracy, large capture range, and fast CPU time for computing external force. It was observed that the GGF snake produced more reasonable results in various image types, such as simple synthetic images, commercial digital camera images, and endoscopic images than previous snakes did.

  • PDF