• Title/Summary/Keyword: Ender nail

Search Result 6, Processing Time 0.018 seconds

The Results of Ender Nailing for the Proximal Humerus Fractures - Radiological Evaluation - (상완골 근위부 골절의 Erlder 정을 이용한 치료 결과-방사선학적 분석 -)

  • Park Jin Soo;Chung Moon Sang;Yoon Kang Sub;Baek Goo Hyun;Lee Ji Ho;Kang Seung Baek;Kim Dong Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.187-198
    • /
    • 1999
  • Purpose: The authors compared the results of Ender nailing for the proximal humerus fractures with those of the conservative methods radiographically. Materials and Method: Nine patients(mean age: 69 years.) received Ender nailing, and the other nine patients, conservative treatments(mean age: 73 years). All fractures were 2 part fractures. The Ender nails were inserted either through posterior elbow approach or transepicondylar approach. A simple Velpeau bandage was applied to the conservative treatment group. The average follow-up was 15 months. Results: The initial status of the anatomical reduction, i.e., the values of the medial shift, overlapping and the varus agulation, were little changed at follow-up radiographs in both the Ender nailing group and the conservative treatment group. There was no significant difference for the status of anatomical reduction between the Ender nailing group and the conservative treatment group. The stability of fixation by Ender nails, i.e., the degree of fanning out of the nails was poor in most cases. Not a few problems/complications happened in cases of Ender nailing group; back­ing out of the nail in three cases, penetration of the nails into the humeral heads in 3, fractures or cracking of the humerus around the nail insertion area in 4 and reduction loss in one. Conclusion: We could not get better results with the use of Ender nail. We use no longer Ender nails for the proximal humerus fractures. Further studies are needed for the better option for the proximal humerus fractures.

  • PDF

Treatment of the Tibia Shaft Fractures with Ender Nails (Ender Nail을 이용한 경골간부 골절의 치료)

  • Kim, In-Ki;Lee, Dong-Chul;Seo, Jae-Sung;Ahn, Myun-Whan;Kim, Se-Dong;Ahn, Jong-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.1
    • /
    • pp.130-136
    • /
    • 1992
  • Fractures of the tibial shaft are the most common among the long bone fractures, and have much difficulty in treatment due to their enumerous complications. Thirty patients with fractures of the tibial shaft were treated with Ender nails under the image intensifier at the Department of Orthopedic Surgery, Yeungnam University Hospital from December 1986 to November 1991. The following results were observed. 1. The average age was 37.3 years and the number of male was three times of the female. The most common cause was traffic accident. 2. Twenty cases out of thirty one were closed fractrure and the remaining 11 were open. The comminuted and segmental fractures were 18(57.7%) in number and the most common fracture site was the middle one third(53%). 3. Average interval from injury to operation was 7.6 days and 19 cases showed associated injuries. 4. The mean duration of the bone union was 18.9 weeks and 2 cases showed the delayed union. 5. Twelve complications were noted such as shortening, varus deformity, delayed union, ankle motion limitation, nail irritation, and soft tissue infection.

  • PDF

Do the Rotating Hinge-Flexible Intramedullary Nail Composites Alleviate Junctional Osteolysis in Megaprothesis Reconstruction for Bone Tumor? (탄력성 있는 골수강 내고정물과 회전경첩형 슬관절 전치환물을 조합한 종양인공관절로 자가골의 골 용해를 감소시킬 수 있는가?)

  • Song, Won-Seok;Cho, Wan-Hyeong;Cho, Sang-Hyun;Jeon, Dae-Geun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.2
    • /
    • pp.96-104
    • /
    • 2007
  • Purpose: The authors investigated whether 35 flexible nail-rotating hinge composite reconstructions around knee joint minimize junctional osteolysis of host bone. Material and Method: The reconstructive technique was as follows: 1) en bloc tumor resection, 2) filling of the host bone marrow cavity with multiple Ender nails, 3) assembling the Ender nails and an Endo-Link type total knee component with wire and bone cement. Result: Mean follow-up was 53 months (ranged 30~79). At final follow-up, 29 patients retained a mobile joint. Resection of more than 40% of bone showed a positive relationship with junctional hypertrophy (p=0.028). Eight patients showed nail breakage and eight prostheses were removed due to early or late infection. The cumulative prosthetic survival rate was 33% at 6 year. Average functional score according to the MSTS criteria was 26.8. Conclusion: Mid-term evaluations showed that results were fair. The revision process was straightforward. Junctional hypertrophy observed appears to give some clues as to how to minimize osteolysis at the prosthesis-host junction after modular prosthesis fixation.

  • PDF

Hemiarthroplasty for Osteosarcoma of Proximal Tibia (근위 경골의 골육종에 시행한 반관절성형술)

  • Jeon, Dae-Geun;Cho, Wan-Hyeong;Kim, Jin-Wook-;Koh, Han-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Purpose: The proximal tibial sarcoma patients, especially in their growing ages have problems of reconstruction. This study is to devise a methodology which can circumvent this limitations. Materials and Methods: Four cases of proximal tibial osteosarcoma underwent hemiarthroplasty. The mean age was 13 years (11~15) with a mean follow-up of 64 months (47~89). The procedure consists of ultrahigh molecular weight polyethylene (UHMWPE) liner as an substitute for the joint surface and this piece was fixed to the remaining tibial bone stock with Ender nail and bone cement. Results: Final functional score was 23.5 (78.3% of control) by MSTS criteria. All the cases showed stable joint without pain. Hemiarthroplasty related complications were absent. By saving the femoral physis, expected leg length discrepancy could be minimized by this procedure. Conclusions: Hemiarthroplasty of proximal tibia can be an option in pediatric sarcoma patients.

  • PDF

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

Limb Salvage Surgery after Removal of Infected Tumor Prosthesis with Equalization of Leg Length (감염된 종양 대치물 제거와 하지 단축 보정 후 시행한 사지 구제술 - 증례 보고 -)

  • Kwon, Young-Ho;Kim, Jae-Do;Chung, So-Hak;Cho, Yool
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • In 1996, a nine-year-old girl was treated with recycling autograft after wide resection of the distal femoral osteosarcoma. The leg lengthening and revision with growing tumor prosthesis were performed due to limb leg discrepancy and epiphyseal problem. However, deep infection developed after operation, and a temporary spacer with cement and Ender nail was inserted. After infection was controlled completely, the final leg lengthening was performed with mono-external fixator for limb length discrepancy (10 cm). Lastly, Tumor prosthesis was reinserted to preserve the joint function.