• 제목/요약/키워드: End-Plate

Search Result 644, Processing Time 0.03 seconds

FEM Analysis on the Strength Safety of a LPG Cylinder (LPG용기의 강도 안전성에 관한 유한요소해석)

  • Kim, Chung-Kyun;Jeong, Nam-In
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.55-59
    • /
    • 2007
  • This paper presents the strength safety of a LPG cylinder, which is fabricated by a steel sheet forming and a welding technology. The strength safety of a cylinder is guaranteed by analyzing a stress distribution of a LPG cylinder structure using a finite element method. The FEM computed results indicate that the hydraulic test gas pressure of $31kg/cm^2$ generates a concentrated local stress near the upper round end plate, which exceeds the yield strength of a LPG cylinder. Thus, the current hydraulic test pressure may be rechecked and revised because this pressure increases the fatigue failure and decreases the lift of the pressure vessel. The normal operation and sealing gas pressures such as $9kg/cm^2\;and\;18.6kg/cm^2$ are relatively safe for a steel LPG cylinder.

  • PDF

Conservation of the Ancient Greek Bronze Helmet donated by Sohn Keechung (손기정 기증 고대 그리스 청동제투구의 보존처리)

  • Park, Haksoo;Jeong, Subin
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.69-79
    • /
    • 2013
  • The area of conservation treatment of the bronze helmet of the ancient Greece, treasure No. 904, which Sohn Keechung (1912 to 2002) received as an extra prize for his winning the marathon in the 1936 Berlin Olympics deteriorated and as a result crack and discoloration occurred. Its nose guard hung downward due to the crack of the bonded area of upper end. Therefore, conservation treatment of the helmet was conducted again. The nose guard was separated from the body. Stabilization and consolidation treatment of them was made and then they were joined again. The cracked and missing areas were reinforced with woven glass fibers, and the nose guard was reinforced with woven glass fibers and Ti plate after the bonding. The joined area of the nose guard was carved with the same pattern as that of the surrounding area and its color was adjusted to be the same as well.

Development of a High-Resolution Electrocardiography for the Detection of Late Potentials (Late Potential의 검출을 위한 고해상도 심전계의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.449-458
    • /
    • 1996
  • Most of the conventional electrocardiowaphs foil to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography(HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as vontricular late potentials(LP). We have developed a HRECG using uncorrected XYZ lead for the detection of LPs. The overall gain of the amplifier is 4000 and the bandwidth is 0.5-300Hz without using 60Hz notch filter. Three 16-bit A/D converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to a PC via a DMA-controlled, optically-coupled serial communication channel. In order to further reduce the noise, we implemented a signal averaging algorithm that averaged many instances of aligned beats. The beat alignment was carried out through the use of a template matching technique that finds a location maximizing cross-correlation with a given beat tem- plate. Beat alignment error was reduced to $\pm$0.25ms. FIR high-pass filter with cut-off frequency of 40Hz was applied to remove the low frequency components of the averaged X, Y, and Z signals. QRS onset and end point were determined from the vector magnitude of the sigrlaIL and some parameters needed to detect the existence of LP were estimated. The entire system was designed for the easy application of the future research topics including the optimal lead system, filter design, new parameter extraction, etc. In the developed HRECG, without signal averaging, the noise level was less than 5$\mu$V$_rms RTI$. With signal averaging of at least 100 beats, the noise level was reduced to 0.5$\mu$V$_rms RTI$, which is low enough to detect LPs. The developed HRECG will provide a new advanced functionality to interpretive ECG analyzers.

  • PDF

Optimum of Gamma Irradiation Dose for Rice-based Infant Foods with Improved Energy-density and Shelf-life (쌀기본 이유식의 에너지 밀도 및 저장성 증대를 위한 최적 감마선 조사 선량)

  • 이유석;오상희;이주운;김장호;김재훈;김관수;김왕근;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.5
    • /
    • pp.894-898
    • /
    • 2004
  • This study was carried out to determine the optimum irradiation dose for infant foods with improved energy-density and extend shelf-life using gamma irradiation. Rice and rice porridge were irradiated at 0, 2.5, 5, 7.5, 10, 15 and 20 kGy, and rheological characteristics and total plate count of porridge were evaluated for 6 weeks. Rice and rice porridge at 2.5 kGy dose reduced the viscosity with 22% and 98%, respectively. The result of total aerobic bacteria of non-irradiated rice porridge was 6 log CFU/g and that of 2.5 kGy irradiated rice porridge on 2 weeks storage was 3 log CFU/g, while that of 7.5 kGy irradiated sample was not detected even at the end of storage. Irradiation on rice-based porridge was proper to enhance the total solid in inverse proportion to considering viscosity and extend shelf-life. Gamma irradiation was effective technology in enhancing calorie value of porridge due to reduction of viscosity.

Comparative Anatomy of the Secondary Xylem in the Root and Stem of Some Korean Lauraceae (수종(數種)의 한국산(韓國産) 녹나무과(科) 식물(植物)에 있어서 뿌리와 줄기의 이기목부(二期木部)의 비교해부(比較解剖))

  • Soh, Woong Young;Lim, Dong Ok
    • Journal of Korean Society of Forest Science
    • /
    • v.76 no.4
    • /
    • pp.317-329
    • /
    • 1987
  • A comparative anatomy between the secondary xylem in the root and the stem of some Korean Lauraceae, including 6 genera and 7 species, was carried out in this study. The results are as follows; diameter and length of vessel element and fiber are wider and longer in the root than the stem. The angle of end wall of vessel element is more inclined in the root than the stem. Also more number of bar on the perforation plate of vessel element in root wood is found. From the anatomical characters of root and stem wood in some Lauraceous species, it is suggested that the wood of the root is phylogenetically mote primitive than that of the stem, except the diameter of vessel element.

  • PDF

Research on prefabricated concrete beam-column joint with high strength bolt-end plate

  • Shufeng, Li;Di, Zhao;Qingning, Li;Huajing, Zhao;Jiaolei, Zhang;Dawei, Yuan
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.395-406
    • /
    • 2020
  • Many prefabricated concrete frame joints have been proposed, and most of them showed good seismic performance. However, there are still some limitations in the proposed fabricated joints. For example, for prefabricated prestressed concrete joints, prefabricated beams and prefabricated columns are assembled as a whole by the pre-stressed steel bar and steel strand in the beams, which brings some troubles to the construction, and the reinforcement in the core area of the joints is complex, and the mechanical mechanism is not clear. Based on the current research results, a new type of fabricated joint of prestressed concrete beams and confined concrete columns is proposed. To study the seismic performance of the joint, the quasi-static test is carried out. The test results show that the nodes exhibit good ductility and energy dissipation. According to the experimental fitting method and the "fixed point pointing" law, the resilience model of this kind of nodes is established, and compared with the experimental results, the two agree well, which can provides a certain reference for elasto-plastic seismic response analysis of this type of structure. Besides, based on the analysis of the factors affecting the shear capacity of the node core area, the formula of shear capacity of the core area of the node is proposed, and the theoretical values of the formula are consistent with the experimental value.

Research on the Heat Transfer and Pressure Drop by Installation Conditions of Rectangular Obstacle in a Solar Air Heater Based on CFD (CFD를 활용한 태양열 공기가열기 내 사각저항체 설치 조건에 따른 열전달 및 압력강하에 관한 연구)

  • Choi, Hwi-Ung;Kim, Young-Bok;Son, Chang-Hyo;Yoon, Jung-In;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.77-89
    • /
    • 2019
  • The solar air heater has various performances according to an obstacle installed in the air duct. Many studies on thermal performance have been conducted. But many of these studies were using a kind of rib type obstacle attached at the bottom of absorbing plate, but they are so hard to be manufactured. In this study, characteristics of the heat transfer and pressure drop in the solar air heater with various horizontal rectangular obstacles was investigated by CFD (Computational Fluid Dynamics) analysis. As a result, the heat transfer performance was improved from 1.2 to 3.32 times depending on installation conditions of rectangular obstacle. The pressure drop, however, also increased with increment of heat transfer performance from 2.8 to 180 times only by changing installation conditions of rectangular obstacle. Thus, the performance factor presenting the thermal performance enhancement on the same pressure drop was also confirmed. As a result, the highest value of 0.828 as better performance factor was obtained at the lower height of rectangular obstacle and this value has started to decrease with increment of heat transfer performance. In the end, it could be confirmed that the pressure drop was carried higher than the quantity of improvement of the heat transfer performance when the heat transfer performance was increased by change of installation conditions of rectangular obstacle. Both heat transfer enhancement and pressure drop to be required for system need to be considered before the rectangular obstacles are applied to the solar air heater.

Analytical Study on Strength Safety of LPG Mini Tank with Column for Level Gauge (레벨게이지용 컬럼을 설치한 LPG 미니탱크의 강도안전성에 관한 해석적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.46-50
    • /
    • 2019
  • In this study, the strength stability of an LPG mini tank with a storage capacity of about 250 kg was analyzed by FEM. According to the results of the FEM analysis, it is preferable that the corner radius of the LPG mini tank having a storage capacity of 250 kg is designed to be 175 to 205 mm. Generally, the larger the corner radius of the end plate of the gas storage tank, the higher the safety of the strength, but the volume or capacity of the tank is reduced. Therefore, it is important to derive the optimum design data. Further, in order to securely design the strength of the gas tank, the thickness of the tank is designed to be thick. However, when the thick steel sheet is used, the material and the transportation costs are increased. The result shows that it is preferable to select the optimum thickness of the steel sheet from 4.5 to 5.5 mm. Using the level gauge type of column on the central axis of the gas tank, the safety strength of the LPG tank can be enhanced as much as twice, compared with the tank of the existing level gauge to measure the liquid level by piercing the side wall of the tank.

Efficient Busbars for Distribution Boards and Distribution Boards R & D Laser Cutting Machine (전기 접속장치인 분전반과 배전반의 효율적인 부스바 절연 피복 레이저 커팅기 연구 개발)

  • Lim, Yeon-Jeong;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.2
    • /
    • pp.1-8
    • /
    • 2019
  • This research is a technology for cutting the insulation of the busbar (busbar) installed in the distribution panel or switchboard, the results of the study, first, the cutting unit and frame of the cutting unit including a housing attached to the upper and lower cutters, respectively Busbar coating laser cutting machine is installed on the top, characterized by consisting of a stopper for adjusting the coating cutting distance of the busbar. Second, the frame is installed with the guide bar in the longitudinal direction at the top so as to be located at the rear side end of the table, the post is installed vertically at the front and rear at the upper middle part, respectively, and cut to the table at the outer side of the front post. It is characterized by the formation of holes. Third, the supporter is fixedly installed on the upper part of the guide bar arranged in the frame, and is characterized by consisting of a cylinder and a support plate. The meaning of this study is to prevent the safety accidents of workers, to improve the efficiency of cutting work, and to prevent the occurrence of scratches on the surface of the busbar.

Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket (천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능)

  • Lee, Seung-Jae;Kwak, Eui-Shin;Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.