• Title/Summary/Keyword: Enclosure

Search Result 644, Processing Time 0.036 seconds

A study on enclosure in Daesoeng-dong Site, Kimhae (김해(金海) 대성동(大成洞) 환호유적(環濠遺蹟) 연구(硏究))

  • Jung, Eui-Do
    • Korean Journal of Heritage: History & Science
    • /
    • v.35
    • /
    • pp.28-56
    • /
    • 2002
  • There is no definite theory, which archeologists have believed to be built either for the protection or ceremonial purpose, of enclosure historical site exhibited from Bronze Age to Samhan era in Korea. The main conditions of choosing right enclosure were natural levee-backswamp-plateau, which all found in village on a hill. For this reasons Kimhae Daesoeng-dong enclosure discovered in 2001 is not an exception, and therefore this enclosure has been believed to be a beginning point of the farming society. In Korea there have been 2 types of enclosure. One is that enclosure entirely surrounds whole historic site itself and the other is that enclosure partially does. Although Kimhae Daesoeng-dong historic site has been discovered only part of it, it's not believed to have the first type-which surrounds the whole enclosure historic site In this research, 3 developing steps of enclosure historic site were defined. Enclosure surrounds only a part of the historic site is 1st step. Enclosure surrounds all around the site is 2nd step. The site discovered with big round clay pottery and developed into multiple enclosure is 3rd step. Since some researches have not been accomplished, the hypothesis above was suggested to have a better understanding of the development of enclosure historic site. The purpose of enclosure has been separately explained for the protection or for the ceremony. It is difficult to assert that excavation sites could be applied to only one of two purposes. But it is possible that both purposes of enclosure such as protection and as division from ceremonial area could be applied together. Kimhae Daesoeng-dong enclosure was shown for the purpose of division from ceremonial area. But we can not ignore that since Kimhae Daesoeng-dong enclosure exposed to the Sea and dwelling area was not shown from village hill, it would be probably for the protection. However enclosure of Gujibong village area in Daesoeng-dong had used for ceremonial purpose since the Bronze Age, even this enclosure would be possible to play an important role of being a center of legend of Gaya foundation. Many unsolved questions are still lying ahead. The enclosure was used for a short time, even if dwelling area was found in and out of enclosure, there were no differences between them, and although duplicate and triplicate enclosure were found, we could not sure which were before and after. Also we could not confirm the type of enclosure with location condition which was the flat land or the top of hill on floodplain. We should not divide the types of enclosure historic site due to differences from cross section of stratum. And I expect that we will have much data such as distribution of enclosure historic site in Yeongnam area where is concerned with origin and diffusion of Japan and China.

NUMERICAL STUDY FOR COOLING CAPACITY IMPROVEMENT OF ENGINE ROOM ENCLOSURE SYSTEM (엔진실 차폐 시스템의 냉각성능 개선을 위한 수치적 연구)

  • Bae, Y.S.;Yoo, G.J.;Choi, H.K.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.39-45
    • /
    • 2009
  • In engine room, proper enclosure system is preferable for reducing noise level but the enclosure system in the engine room causes bad influence on cooling performance due to poor ventilation. Cooling efficiency of the enclosure system can be improved by varying fan speed and proper flow path for ventilation. In this study, numerical analysis is performed to assess cooling effect of the enclosure system using finite volume method. The RNG k-$\varepsilon$ model is adopted for turbulence model along with heat exchanger model and porous media model for heat exchanger analysis, and moving reference frame model for rotational fan. Verification result shows reasonable agreement with experimental data. Analysis results show direct effect of velocity and temperature distribution on cooling ability in the enclosure system. Enclosure system of case B shows high heat transfer coefficient and has the smallest area ratio of opened flow passages which is good for noise level reduction.

Effects of Inclination of Enclosure and Partition on Natural Convective Heat Transfer in a Partitioned Enclosure (격판을 가진 밀폐공간내의 자연대류 열전달에 공간 및 격판의 경사가 미치는 영향)

  • Chung, I.K.;Song, D.J.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.302-314
    • /
    • 1994
  • The effects of the inclination of enclosure and partition on natural convective flow and heat transfer were investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was positioned perpendicularly at the mid-height of one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were performed with the variations of the partition length and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). The effects of the inclination angle of enclosure and partition on the heat transfer within an enclosure were also studied. As the results, the increase of the inclination angle of enclosure rapidly raised the heat transfer rate, while the inclination angle for the maximum Nusselt number was retarded with the increase of the partition length and the decrease of the heat transfer rate became larger in proportion to the increase of the partition length. The Nusselt number obtained by the inclination of partition was smaller than that of the inclination of enclosure. However, the difference of the heat transfer rates was considerably decreased at the longer partition lengths and the trends for the variation of the average Nusselt number were more similar with that of the inclination of enclosure. The upward oriented partition increases the convective heat transfer distinctly in contrast to that of the inclination of enclosure as the partition length increases.

  • PDF

Analysis of the Sound Insertion Loss of the Enclosure for the Chilled Water Plant in a Ship (선박의 냉수제조기용 인클로우져에 대한 음향 삽입 손실 분석)

  • Han, Hyung-Suk;Jang, Cheon-Ik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.152-157
    • /
    • 2008
  • Enclosure is widely used for the sound insulation in a ship. But it is very difficult to estimate the sound insertion loss for the enclosure because the sound field between the enclosure and the machine is so complex. Therefore, it is usually estimated experimentally. In this research, sound insertion loss of the enclosure is estimated by theory assuming that the sound field in the enclosure is reverberation field. And the results from the theory are compared to those from the experiment.

  • PDF

A Study on Flammable Mixture Formation in a Rectangular Enclosure with Gaseous Fuel Leak from the Bottom (직사각형 밀폐공간내에 기체연료 밑면 누출시 가연성 혼합기 생성에 관한 연구)

  • Chung, N.K.;Kim, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.249-256
    • /
    • 1993
  • Numerical method is applied to predict the time variation behavior of flammable mixture formation in a two dimensional enclosure from the beginning of gas leak. Additionally experimental method is used to consider qualitative aspects. Characteristics of flammable mixture formation such as distribution of flow and fuel mass fraction at various locations in the enclosure are determined for the following parameters: the various locations of leak at the bottom and aspect ratio of the enclosure. In the case of gas leak with small leak velocity from the bottom of enclosure gravitational force affects the formation of flammable mixture. Aspect ratio of the enclosure also affects the formation of flammable mixture. The volume of the region of recirculating flow is dominant factor affecting the formation mixture.

  • PDF

A Quantitative Separation Method of Structure and Air Borne Sound Power from the Enclosure (차음구조물의 방사음향파워로부터 고체 및 공기전파음향파워의 정량적인 분리법)

  • 김의간;강동림
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.85-96
    • /
    • 1992
  • Engine enclosures are widely adopted to reduce the noise emission in various fields of application. The radiated noise, which is due to the vibration of enclosure's outer surface, is composed of two kinds of sound power with different path of propagation. One is the 'structure-borne sound power' which stems from the engine's vibratory force applied to the structure of enclosure through the mounting parts of engine etc., while the other is the 'air-borne sound power' which is originated by the sound power radiated from the engine surface to the inner space of enclosure that should excite the vibration of enclosure from inside. In order to get a most efficient engine enclosure is required a profound consideration upon the above structure-borne and air-borne noise, since the guiding principle of countermeasure for each noise is quite different. The controlling of input vibration and its isolation are major subject for the structure-borne sound power and the specifications of absorbing member and damping panels are the major interests for the air-borne sound power. Hence it seems very efficient to separate the total sound power into two categories with a great accuracy when one think of further reduction of engine noise from the exciting enclosure, however, its separating methods have not been made clear for many years. Then author proposes a new practical separation method of two propagation path's contribution to the total radiation sound power for the enclosure under the engine operating condition.

  • PDF

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

An effect of Radiation Heat Transfer on the Thermal Dissipation from the Electronic Chip in an Enclosure (밀폐공간에 놓인 전자 칩의 열발산에 복사 열전달이 미치는 영향)

  • Choi, In-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.4
    • /
    • pp.179-186
    • /
    • 2009
  • Electronic components in an enclosure have been investigated to prevent undesired thermal problems. The electronic devices, such as ECUs of automotive engines, are operated under the contaminated environments, so that they rely on the passive cooling without any fluid-driving methods. Therefore the radiation heat dissipation plays more important role than the conduction and convection heat transfer. Hence their combined heat dissipation phenomena have been simulated by a numerical model to reveal the effects of supplied heat flux, emissivity of material, geometry of enclosure, charging gas and pressure. The result showed that the radiation had a significant effect on the heat dissipation of module in an enclosure, and some space above the module should be reserved to prevent its thermal problem. In addition, the higher thermal conductivity and pressure of gas in an enclosure could be necessary to improve the thermal dissipation from the electronic devices.

  • PDF

Effect of a Solid Insert on Thermal Stratification in a Side-Heated Natural Convection Enclosure (측면가열 자연대류 밀폐공간에서 고체 삽입물이 열성층화에 미치는 영향)

  • 김수현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.211-217
    • /
    • 2004
  • Effect of a solid insert on thermal stratification in the natural convection enclosure is numerically investigated. The enclosure consists of two differently heated vertical walls and two adiabatic horizontal walls. A solid insert is located in the middle of the enclosure. The non-dimensional governing equations are solved by using the SIMPLER algorithm. The computations are carried out with the variations of thermal conductivity, width and height of the solid insert. The Prandtl number of the fluid in an enclosure is fixed at Pr=0.71, Two cases of Rayleigh number are considered in the present study, i.e., Ra:10$^3$ and 10$^{6}$ . The thermal stratification attenuates as thermal conductivity, width, and height of the solid insert are increased. As the thermal conductivity ratio of a solid insert to fluid increases beyond (equation omitted)10$^3$, the thermal stratification ratio shows an asymptotic value.

A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant (가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로)

  • Kim, Young-Chul;Jo, Il-Hyun;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • The present study was aimed to analyze enclosure integrity test, which is the performance experiment of soaking time, in a fire zone equipped with gaseous extinguishing system in an effort to find understand the effect of precaution factors upon the success of fire extinguishment. To achieve the goal of this study, it divided the fire zones of internal and external power plants into ones taking precaution measures and not taking them and then enclosure integrity test was given respectively. Therefore, this study examined the success rate if the test according to the presence and absence of the precaution measure and confirmed the failure factors, designed concentration soaking time and proportion of leakage area to total volume area by type of gaseous extinguishing system and rooms. Precaution measures were applied to the fire zones without them to confirm the increase of the success rate of enclosure integrity test. By doing so, it was found that reduced number of experiments caused by failure led to cost saving.