• Title/Summary/Keyword: Enantiomer resolution

Search Result 47, Processing Time 0.023 seconds

Enantiomer Separation of Chiral Amino Alcohols as 9-anthraldimine Derivatives on Coated and Covalently Bonded Chiral Stationary Phases Based on Polysaccharide Derivatives by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 다당 유도체를 기초로 한 흡착되거나 공유결합된 키랄 고정상에서 키랄 아미노 알코올의 안트르알디민 유도체의 광학분리)

  • Xu, Wen Jun;Jin, Jing Yu;Lee, Won-Jae
    • KSBB Journal
    • /
    • v.26 no.4
    • /
    • pp.323-327
    • /
    • 2011
  • The convenient derivatization method of chiral amino alcohols as 9-anthraldimine Schiff base derivatives for chiral resolution was developed and the liquid chromatographic enantiomer separation of chiral amino alcohols as 9-anthraldimine derivatives was investigated on several coated and covalently bonded polysaccharide-derived chiral stationary phases (CSPs). In general, the performance of Chiralcel OD-H (or Chiralcel OD) (${\alpha}$ = 1.24-2.89), the coated CSP derived from cellulose derivative was superior to the other CSPs for resolution of 9-anthraldimine derivatives of several amino alcohols. The results of enantioseparation depending on the structure of 9-anthraldimine analytes like the steric bulky group and the polar moiety etc were discussed. The analytical method was applied to measure the enantiomeric purity of commercially available chiral amino alcohols. It is expected that the convenient analytical method will be very efficient for determination of enantiomeric purity of amino alcohols as 9-anthraldimine Schiff base derivatives with strong UV absorption.

The Application of Chiral HPLC Columns for Enantiomer Separation of Chiral Drugs (Chiral Drugs의 광학분할을 위한 HPLC Column의 응용)

  • Lee, Won-Jae
    • YAKHAK HOEJI
    • /
    • v.53 no.2
    • /
    • pp.60-68
    • /
    • 2009
  • In terms of chiral issue, two enantiomers of chiral drugs often differ significantly in their pharmacological, toxicological and pharmacokinetic profile. Chiral switches of racemic drugs have been redeveloped as single enantiomers. Several chiral resolution techniques in chirotechnology are introduced and the most used chiral HPLC chromatographic method among several chiral analysis techniques is described with its several advantages. Several types of chiral HPLC columns derived from their chiral selectors are discussed with their property and applications for enantiomer separation.

Separation of racemic enantiomer carvedilol and its metabolites using capillary electrophoresis (Capillary Electrophoresis에 의한 carvedilol 및 그 대사체의 거울상이성질체 분리)

  • Jo, Cheon-Ho;Koo, So-Hyun;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.275-279
    • /
    • 2006
  • A capillary electrophoresis method for the separation of carvedilol and its metabolites enantiomers using cyclodextrins as the chiral selectors was developed. The effect of several types of cyclodextrins, concentration and capillary temperature for enantiomer resolution were investigated. Best results were obtained by 15 mM carboxymethyl-${\beta}$-cyclodextrin in the run buffer. Also the effect of capillary temperature on efficiency was assessed. The optimized method was applied for separation of chiral carvedilol and its three metabolites.

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-phase High Performance Liquid Chromatography after Derivatization with (S)-(-)-${\alpha}$-methylbenzyl isocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun;Kwon, Young-Hee;Sohn, Young-Teak
    • Archives of Pharmacal Research
    • /
    • v.20 no.5
    • /
    • pp.486-490
    • /
    • 1997
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with (S)-(-)-${\alpha}$-methyl-benzyl isocyanate, the diastereomeric derivatives were resolved $(R_s=1.59)$ on $5{\mu}M$ octadecylsilan column using 47% methanol as a mobile phase with fluorescence detection. The detection limit of each enantiomer was 10 ng/ml (S/N=3).

  • PDF

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-Phase High Performance Liquid Chromatography after Derivatization with 2,3,4,6-Tetra-O-acetyl-${\beta}$-D-glucopyranosyl Isothiocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun
    • Archives of Pharmacal Research
    • /
    • v.21 no.2
    • /
    • pp.217-222
    • /
    • 1998
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with 2,3,4,6-tetra-O-acetyl-$\beta$-D-glucopyranosyl isothiocyanate, the diastereomeric derivatives were resolved (Rs=1.83) on $5{\mu}m$ octadecylsilan column using 35% acetonitrile in 0.05M ammonium acetate buffer (pH=6) as a mobile phase with electrochemical detection. The diastereomeric derivatives were formed within 30 min. The detection limit of each enantiomer was 20 ng/ml (S/N=3).

  • PDF

A Newly Developed Analytical and Semi-preparative Enantiomer Separation of Fluoxetine using Polysaccharide-derived Chiral Stationary Phases by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 다당 유도체의 키랄 고정상에서 플록세틴의 새롭게 개발된 분석 및 반분취의 광학분리)

  • Kim, Seok Jin;Nam, Kyung Wook;Park, Bohyun;Islam, Md. Fokhrul;Lee, Wonjae
    • KSBB Journal
    • /
    • v.31 no.3
    • /
    • pp.186-191
    • /
    • 2016
  • A liquid chromatographic method for the enantiomer separation of fluoxetine was performed using covalently bonded and coated type polysaccharide-derived chiral stationary phases (CSPs). The degree of enantioseparation is affected by the used CSPs and mobile phases. The performance of Chiralpak IC was superior to the other CSPs used in this study. Out of various solvent composition and additives, the greatest separation and resolution was observed using Chiralpak IC with mobile phase of 2-propanol in hexane with diethylamine as an additive. Semi-preparative separation of fluoxetine was performed on the analytical Chiralpak IC column to obtain (R)- and (S)-fluoxetine enantiomer with high chemical and optical purity. From the overall study, the developed liquid chromatographic method on polysaccharide-derived CSPs is expected to be very useful for the enantiomer separation of fluoxetine.

Chromatographic Enantiomer Separation and Determination of Optical Purity for α-Amino Acid Esters as 9-Anthraldimine Derivatives Using Polysaccharide Based Chiral Columns (다당 유도체를 기초로 한 키랄 컬럼에서 아미노산 에스테르의 안트르알디민 유도체의 광학분리 및 광학순도 측정)

  • Huang, Hu;Jin, Jing-Yu;Lee, Won-Jae
    • KSBB Journal
    • /
    • v.26 no.2
    • /
    • pp.139-142
    • /
    • 2011
  • The chromatographic enantiomer separation of 9-anthraldimine derivatives of ${\alpha}$-amino acid methyl and ethyl esters on four polysaccharide based chiral columns was performed. The 9-anthraldehyde Schiff base derivatives of ${\alpha}$- amino acid esters were readily synthesized by stirring the ${\alpha}$- amino acid ester hydrochloride salts with 9-anthraldehyde in the presence of 1,8-diazabicyclo [5.4.0]undec-7-ene as a base and anhydrous $MgSO_4$. Chiralcel OD or Chiralcel OD-H showed the greatest enantiomer resolution of 9-anthraldimine derivatives of ${\alpha}$-amino acid methyl and ethyl esters. The L-enantiomers of all the analytes were preferentially retained on Chiralcel OD or Chiralcel OD-H. This analytical method was applied in the determination of optical purities of several commercially available D- or L-${\alpha}$-amino acid methyl esters.

Enantiomer separation using a covalently immobilized chiral column derived from polysaccharide derivative by reversed phase liquid chromatography (역상 크로마토그래피에서 다당유도체로 공유결합된 키랄 컬럼을 이용한 거울상 이성질체의 광학분리)

  • Huang, Hu;Jin, Jing Yu;Baek, Chae-Sun;Lee, Wonjae
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.148-151
    • /
    • 2009
  • Enantiomer separation of N-fluorenylmethoxycarbonyl (FMOC) $\alpha$-amino acid was performed on covalently immobilized chiral column (Chiralpak IB) based on polysaccharide derivative as a chiral selector by reversed phase liquid chromatography. The effect of the reversed mobile phase on the chromatographic parameters of the enantioselectivities, resolution factors and retention times using covalently immobilized Chiralpak IB was shown. Also the enantiomer separation of N-FMOC $\alpha$-amino acid in the reversed and normal phase was compared and the results obtained in the former mobile phase were generally lower than those in the latter mobile phase.

The Effect of Mobile Phase and Dissolving Solvent on the Enantiomer Separation Using a Covalently Immobilized Chiral Column Derived from Polysaccharide Derivative (다당유도체로 공유결합된 카이랄 칼럼에서 이동상과 분석물질의 용매가 거울상 이성질체의 광학분할에 미치는 영향)

  • Huang, Hu;Lee, Beom-Gyu;Baek, Chae-Sun;Lee, Won-Jae
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.2
    • /
    • pp.137-143
    • /
    • 2009
  • Liquid chromatographic enantiomer separation of N-tert-butoxycarbonyl (BOC) $\alpha$-amino acids and their ethyl esters was performed on covalently immobilized chiral column (Chiralpak IC) derived from polysaccharide derivative. The solvent versatility of the covalently immobilized Chiralpak IC in enantiomer separation of N-BOC $\alpha$-amino acid ethyl ester derivatives was shown and the chromatographic parameters of their enantioselectivities and resolution factors were greatly influenced by the nature of the mobile phase. Also the effect on the dissolving solvent for these analytes on the enantiomer separation using the same mobile phase and the examples of preparative enantiomer separation on analytical column were shown.

Empirical Equation for Resolution if Ibuprofen Enantiomers by Chiral High-Performance Liquid Chromatography (키랄 고성능 액체 크로마토그래피를 이용하 이부프로펜의 분리도에 관한 실험식)

  • 여미순;노경호
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.261-265
    • /
    • 2003
  • Ibuprofen was analyzed by chiral high performance liquid chromatography. Retention behaviours of the standard mixtures of ibuprofen were investigated to obtain their acceptable resolution. A chromatographic column (3.9 ${\times}$ 300 mm) was packed by Kromasil CHI-TBB packings (10 $\mu\textrm{m}$) and n-hexane was used as a mobile phase with 0.1% acetic acid and tert-butyl methyl ether. Isocratic elution of ibuprofen at 1.0 $m\ell$/min was performed by changing the mobile phase compositions. The experimental variables affecting the resolution were the compositions of mobile phase and chemical buffer (n-hexane and tert-butyl methyl ether). The resolution between the enantiomers were correlated into the several types of empirical equations including linear form, and their agreements between experimental data and calculated values were examined by the regression coefficient.